The A431 Radio Module
#
prompt should appear on the terminal screen (nnnn is the actual ID of the unit that
is printed on its label). The following default parameters must be pre-loaded (for
more information about the meaning of the commands, consult the section "Com-
mands" on page 51):

Commands valid for all bands

ID 1
PMP 65 72
SLOT 900 15
RSSI 58

Commands required for band 1

SR 430000000 440000000
BL 430000000 440000000
FREQ 435000000 12500

Commands required for band 2

SR 440000000 450000000
BL 440000000 450000000
FREQ 445000000 12500

Commands required for band 3

SR 450000000 460000000
BL 450000000 460000000
FREQ 455000000 12500

Commands required for band 4

SR 460000000 470000000
BL 460000000 470000000
FREQ 465000000 12500
Note: The SR command sets the switching range limits, the BL command sets the
32
band limits, and the FREQ command sets the actual operating frequency;
before shipping and depending on the target country, these parameters may
be changed. The SL command must be always issued before the BL com-
mand and the BL command must always be issued before the FREQ com-
mand.