Download Print this page

Klein + Hummel P 110/N Installation And Operation Manual

Advertisement

Quick Links

P110
Studio Monitor
Installation and Operation

Advertisement

loading

Summary of Contents for Klein + Hummel P 110/N

  • Page 1 P110 Studio Monitor Installation and Operation...
  • Page 2 Safety Instructions It is absolutely essential that you read these safety instructions carefully before connecting and using this K+H product. Your safety depends on it. Furthermore, failure to follow these instructions voids the warranty. To ensure safe operation for years to come, keep these instructions in a safe place for future reference. K+H has manufactured this product in accordance with IEC 92 (SEC) 39 standards, then tested and delivered it in safe operating condition.
  • Page 3 Passive Nearfield Monitor P 110/N and P 110/H Installation - Operation Figure 1: Front view of P 110 Figure 2: Input, P 110/N and P 110/H Figure 3: Room EQ, P 110/N Figure 4: Power Range, P 110/H Page 3...
  • Page 4 O 110. The P 110 is Please ensure that these threaded holes are offered in a low impedance 8 Ohm version ( P 110/N) always plugged so that the volume of air sealed and with a 100 Volt/ 166 Ohm transformer connection within the cabinet may only pass through the (P 110/H).
  • Page 5 So ly evident in the test plots presented in Figure 6 and 7. an elliptical horn for the tweeter was added. Thus came Figure 8: Frequency response, (“freefield“) Figure 9: Impedance of P 110/N Page 5...
  • Page 6 The loudspeaker’s cumulative spectral decay plot indicates a very clean decay without any major resonances or standing waves being evident. Figure 12 : Meterbridge EQ, P 110/N 3. Warranty Information acknowledged under condition that the complaint is All K+H products undergo an extensive procedure of filed to our distributor or to us in writing within 8 days quality control testing before leaving the factory.
  • Page 7 4. Technical Specifications P 110/N P 110/H Sensitivity 87 dB/SPL/W/m 86 dB/SPL/W/m 111,5 dB/SPL 110,5 dB/SPL short term at 1 m (half...) Ω Ω 166/333/666 , switchable Impedance 80 W 60/30/15 W, switchable Nominal power handling capacity 85 Hz - 20 kHz, ± 2 dB 85 hz - 20 kHz, ±...
  • Page 8 K+H Vertriebs- und Entwicklungsgesellschaft mbH 30900 Wedemark, Germany Phone +49 (5130) 58 48 0 Fax +49 (5130) 58 48 11 www.klein-hummel.com Printed 11/06 518152...

This manual is also suitable for:

P 110/h