CLA-VAL 50B-5KG Installation, Operation And Maintenance Manual

CLA-VAL 50B-5KG Installation, Operation And Maintenance Manual

Pump suction control valve; 600 series hytrol valve; valve position indicator & pilot system components
Hide thumbs Also See for 50B-5KG:

Advertisement

Quick Links

Distributed By: M&M Control Service, Inc.
www.mmcontrol.com/claval-index.php
800-876-0036
847-356-0566
50B-5KG/2050B-5KG
Distributed By:
M&M Control Service, Inc.
Phone: 800-876-0036
Fax: 847-356-0747
Email: sales@mmcontrol.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 50B-5KG and is the answer not in the manual?

Questions and answers

Summary of Contents for CLA-VAL 50B-5KG

  • Page 1 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 50B-5KG/2050B-5KG Distributed By: M&M Control Service, Inc. Phone: 800-876-0036 Fax: 847-356-0747 Email: sales@mmcontrol.com...
  • Page 2 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566...
  • Page 3 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566...
  • Page 4: Typical Installation

    End Details 150 and 300 ANSI B16.42 supply, the Model 50B-5KG, sensing the pump suction, modulates to prevent suction pressure from dropping below a pre-set minimum. Pressure Ratings 150 class - 250 psi Max.
  • Page 5: Flow Chart

    The valve shall be Factory Mutual Approved. It shall be the a single removable seat, a delrin-sleeved guided stem and a MODEL 50B-5KG FIRE PUMP SUCTION CONTROL VALVE renewable resilient synthetic rubber disc with a rectangular as manufactured by Cla-Val, Newport Beach, California.
  • Page 6 (usually atmosphere) the line pressure With the use of a Cla-Val. "modulating chamber the valve closes drip-tight. (5 psi Min.) at the valve inlet opens the control," which reacts to line pressure valve.
  • Page 7: Troubleshooting

    When flow is “up-and-over the seat,” it is in “normal” flow and the valve will fail in the open position. When flow is “over- 2. Cla-Val Model X101 Valve Position Indicator. This pro- the seat-and down,” it is in “reverse” flow and the valve will fail in the closed position.
  • Page 8 (See “Maintenance” the valve should be fully open. Section for procedure.) 6. If the valve has a Cla-Val X101 Position Indicator, observe the Tight Sealing Check (#3) indicator to see that the valve opens wide. Mark the point of max- imum opening.
  • Page 9 Thread Size (UNF Internal) 1 1/4" —2 1/2" Preventative Maintenance 10—32 3"—4" 1/4—28 The Cla-Val Co. Model 100-01 Hytrol Valve requires no lubrication or 6"—14" 3/8—24 packing and a minimum of maintenance. However, a periodic inspec- 16" 1/2—20 tion schedule should be established to determine how the operating 24"...
  • Page 10 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 Inspection of Parts Lime Deposits After the valve has been disassembled, each part should be One of the easiest ways to remove lime deposits from the valve examined carefully for signs of wear, corrosion, or any other stem or other metal parts is to dip them in a 5-percent muriatic abnormal condition.
  • Page 11 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 INLET OUTLET TOP VIEW GLOBE PATTERN PARTS LIST Item Description Pipe Plug Drive Screws (for nameplate) Hex Nut (8” and larger) Stud (8” and larger) Cover Bearing Cover Stem Nut Diaphragm Washer Diaphragm Spacer Washers Disc Guide...
  • Page 12 -the body- that is different from standard 100 diaphragm-actuated, globe or angle pattern valve. Series Cla-Val main valve parts. The remaining parts of the 600 series main valve are standard Cla-Val main valve parts. This valve consists of three major components; body, diaphragm All service and maintenance information for the standard 100 assembly, and cover.
  • Page 13 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 100-01 Hytrol Main Valve Assembly BOLT/NUT TORQUING PROCEDURES ON VALVE COVERS PIPE PLUG HEX NUT COVER 8" and Larger PIPE PLUG Cover Bolt 6" and Smaller COVER BEARING BOLTS BOLTS BOLTS SPRING STEM NUT DIAPHRAGM WASHER...
  • Page 14 Basic Main Valve Size Comparison parts are going to be for a smaller size main valve. Cla-Val iden- tifies main valve parts with the flange size of the standard 100 Globe Pattern Valves Series main valve.
  • Page 15 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 100-20 PARTS LIST DESCRIPTION Pipe Plug Drive Screws (for nameplate) Hex Nut (8" and larger) Stud (8" and larger) Cover Bearing Cover Stem Nut Diaphragm Washer Diaphragm Spacer Washers Disc Guide Disc Retainer Disc Stem...
  • Page 16 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566...
  • Page 17: Parts List

    Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 PARTS LIST X44A Strainer and Orifice Assembly BRONZE BODY — S.S. ORIFICE 3/8" x 3/8" ORIFICE PLUG X44A STOCK NO. ORIFICE DIA. PART # (ITEM 5) 71310-01 .031 94132-01 .046 .062 .078 .093 1/8 NPT...
  • Page 18: Flow Control

    (400) wet or dry sandpaper can be used with water. Rinse parts in water before handling. An appropriate solvent can The Cla-Val Model CV Flow Control is a simply-designed, clean parts used in fueling service. Dry with compressed air spring-loaded check valve. Rate of flow is full flow in one direc- or a clean, lint-free cloth.
  • Page 19 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 PARTS LIST 3/8" Flow Control ADJUSTING STEM (TURN CLOCKWISE TO INCREASE RESTRICTION) 2.12 STAMP PART NO. ON SMOOTH SURFACE RESTRICTED FLOW 3/8 - 18 NPT 1.84 When ordering parts, please specify: •...
  • Page 20 • Easy Maintenance and Cleaning • Protected Indicator Rod The Cla-Val Model X101 Visual Position Indicator is designed to display Cla-Val valve position quickly and easily. A solid brass indicator rod fastened directly to the valve stem moves up and down inside a pyrex tube.
  • Page 21 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 CDS6 Altitude Control CSM-11 Solenoid Control Body Material Wetted Body Material Standard: Bronze with Standard: Bronze with Stainless Steel Monel Trim Trim Option: Bronze with Stainless Steel Trim No. of Springs Altitude Ranges 5 - 40 ft 30 - 80 ft...
  • Page 22 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 PARTS LIST X101 Valve Position Indicator COMPLETE X101 SIZE STOCK NO. 1 1/4 - 1 1/2 C2812A C8972G 2 1/2 C2607E C2609A 9710001A 9710002J C8581F C9187A 31420D 30256C 30251D ITEM DESCRIPTION MATERIAL Vent Valve Brass...
  • Page 23 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566...
  • Page 24: How To Order

    INLET SIZE & inquiries concerning valve operation, it is important to CAT NO. EINTRITT STOCK properly identify Cla-Val products already in service CODE ENTREE by including all nameplate data with your inquiry. MFD. BY CLA-VAL ENTRADA Pertinent product data includes valve function, size, NEWPORT BEACH, CALIF, U.S.A.
  • Page 25 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 SPECIFY WHEN ORDERING HOW TO ORDER • Model Number • Valve Size • Globe or Angle Pattern • Threaded or Flanged Distributed By: • Adjustment Range • Body and Trim Materials (As Applicable) •...
  • Page 26: Repair Kits

    Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 INSTALLATION / OPERATION / MAINTENANCE REPAIR KITS MODEL Complete Replacement Diaphragm Assemblies for 100-01 and 100-20 Hytrol Main Valves For: Hytrol Main Valves with Ductile Iron, Bronze Trim Materials—125/150 Pressure Class Only. FACTORY ASSEMBLED Includes: Stem, Disc Guide, Disc, Disc Retainer, Spacer Washers, Diaphragm, Diaphragm Washer and Stem Nut.
  • Page 27 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/claval-index.php 800-876-0036 847-356-0566 Repair Kits for 100-02/100-21 Powertrol and 100-03/100-22 Powercheck Main Valves For: Powertrol and Powercheck Main Valves—125/150 Pressure Class Only Includes: Diaphragm, Disc (or Disc Assembly) and O-rings and full set of spare Spacer Washers. Kit Stock Number Valve Kit Stock Number...

This manual is also suitable for:

X101100-01100-20Cv

Table of Contents