2.1 INSTALLATION WARNINGS

This section contains technical information concerning the installation of the product. The regulation in force
and the code of practice must be followed for every aspect concerning the installation (safety and security,
WARNING
environment protection, etc...). According to all applicable regulations and requirements, the systems must be
designed by qualified professionals only.
The Rinnai Infinity is conceived as continuous flow water heater. The appliance is suitable for domestic use to produce
hot water. The appliance must be power plugged, gas fuelled and connected to a hot water delivery system suitable
for the water heater power and features.
Rinnai gas appliances must be installed by qualified personnel only, according to local regulations, to the law in force
and following the principles of the code of practice.

2.1.1 APPLIANCE LOCATION

This appliance is designed for 'Outdoor' installation only. As such, it must be located in an above ground open air
situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection.
The water heater can be installed outdoor with no protections against rain, snow, etc. All pipes
must be wrapped with appropriate insulating materials to prevent freezing.
NOTE
The min allowed temperature is -20°C (when protected from direct wind exposure).
This appliance must be mounted on a vertical structure with the water and gas connections on the underside pointing
downwards. Location of the appliance flue terminal must be in accordance with local and national laws.
This appliance must be placed as close as practicable to the most frequently used hot water outlets to minimise the
delay time for hot water delivery. For installations where the distance between the water heater and the outlets is
considerable, a flow and return system or the 'circulation kit' Rinnai (RCD-XHF) system can be used to minimise the
waiting time for hot water delivery.
An AC 230V/50Hz, earthed power point must be provided adjacent to the appliance. For outdoor installations this
power point must be weather proof. It must be clear of the gas and water connections to the appliance and also the
flue exhaust and water pressure relief valve. The power cord of the appliance is 1.5 metres long.
All appliances must be installed to ensure access can be gained without hazard or undue difficulty for inspection,
repair, renewal or operational purposes. Sufficient clearances shall allow access to, and removal of, all serviceable
components.
This appliance must not be used as a domestic spa or swimming pool heater.
Both support brackets must be fastened with metal plugs.
The water heater must be easily accessible for maintenance.
Provide for the installation of an appropriate system to collect water from the pressure relief valve and to collect and
drain water under the appliance to prevent material and property damages in case of water leakage.
The flue system must respect the minimum clearance prescriptions and applicable regulations.
Air surrounding the water heater, venting and vent termination is used for combustion and must be free of any
compounds that cause corrosion of internal components. These include corrosive compounds that are found in aerosol
sprays, detergents, bleaches, cleaning solvents, oil based paints/ varnishes, and refrigerants.
Do not install the appliance near combustible objects, chemical products or corrosive agents. If it is necessary for
a water heater to be located in areas which may contain corrosive compounds, Rinnai strongly recommends the
following: install as far away as possible from exhaust vent hoods; install as far away as possible from air inlet vents.
Corrosive fumes may be released through these vents when air is not being brought in through them.
Chemicals that are corrosive in nature should not be stored or used near the water heater or vent termination.
Damage and repair due to corrosive compounds in the air is not covered by warranty.
Coastal installations
Installations located in or near coastal areas may require additional maintance due to corrosive airborne ocean salt.