6X Blink - Backlight Converter System Failure
If the converter circuits fails to generate high voltage or one or more of
the backlight fails to light, the television will shut down and display this
diagnostics error.

TRIAGE CHART

Use this general Triage Chart to determine what may possibly be causing the error before going out to the customers location.
1. Confirm the symptom from the customer.
2. Select that symptom from the chart.
3. Bring the primary component listed for that symptom.
4. Follow the associated flowcharts in the Training Manual to isolate the board.
5. Chart Color Code
Board
Main Board
Power Supply
H Board
LCD Panel
TCON
*NOTE: REFER TO LCD PANEL SERVICE
MANUAL IN REFERENCE LIBRARY DATABASE
FOR CORRECT REPLACEMENT PARTS BASED
KDL-22EX357/32EX357/32EX358/40EX457/40EX458
Protection Modes
2X
3X
5X
6X
7X
*
***
**
* TV Immediate Shuts Off After Power ON & 7X
**Backlight Turns ON before TV Shuts Off
***Backlight Does NOT Turn ON before TV Shuts
SECTION 2 - TROUBLESHOOTING
7X Blink - Temperature Failure
A digital thermometer IC located on the Main Board provides a temperature
reading of the chassis and LCD panel. If the temperature exceeds a pre-
determined point the TV will shut down. If this problem occurs immediately
at turn-on, the temperature sensing IC has failed and replacing the main
board is required. If this occurs after the TV has been running for a while,
check for ventilation issues that could cause the TV to run hotter than
normal.
RED DOT: (Primary) Most likely defective part
BLUE Triangle: (Secondary) Possible defective part
Video
Power
Whole
Isolated
No
Dead set
Screen
Video
Distortion
Distortion
Audio
Area
No Audio