SPECIFICATIONS
Lyric T6/T6R Thermostat
Adaptive Fuzzy Logic
Control form
From 0
Room
Temperature
display range
Lyric T6 (wired) 103 x 103 x 28 mm
Dimensions
(w x h x d)
Lyric T6R (wireless) 108 x 103 x 68 mm
24 hour or 12 hour AM/PM format
Time display
Synchronized with Internet when
Time keeping
accuracy
connected or typically better than 10
minutes per year
5+2 or daily schedule with 6 daily time
Program
and temperature level changes
Program - 10 minute steps
Time setting
resolution
Sensing
100K (@ 25
element
Program : 5 to 37
Temperature
setting range
OFF
Lyric T6 (wired) ~20VDC/300mA by
Power
Receiver box
Lyric T6R (wireless) 5VDC power
adapter
Lyric T6 (wired) terminal block capable
Wiring
of accepting wires up to 1.5 mm
RF communication
ISM (868.0-868.6) MHz, 1% duty cycle
RF operation
band
25mW
Max. power
Encrypted
Protocol
30 m in a residential building
Comm. Range
environment
short, high rate transmissions to
Comm.
technology
minimise air time and avoid collisions
RX Cat 2 (ETSI EN300 220-1 version
Receiver class
R.E.D.
1.3.1)
Factory pre-bound
RF binding
method
IEEE 802.11b/g/n – 2.4GHz
Wi-Fi
10mW
Max. power
C to 50
C
o
o
C ) NTC thermistor
o
C in 0.5
C steps
o
o
: 5
C
o
2
Receiver box
230VAC
Power
Electrical rating 230 V~, 50...60 Hz, 0.5 A to 5 A resistive
0.5 A to 3 A inductive (0.6 pf)
24 V~, 50...60 Hz, 0.5 A to 5 A resistive
0.5 A to 3 A inductive (0.6 pf)
Selectable by application (see installer
Cycle rate
set up)
Terminal block capable of accepting
Wiring
wires up to 1.5 mm
From back via large wall box opening.
Wire access
From bottom with cable clamps.
Mains wiring – left.
Low voltage wiring – right.
110 x 110 x 40 mm (w x h x d)
Dimensions
30
IP class
Environmental and standards
0 to 40
Operating
temperature range
-20 to 55
Shipping and storage
temperature
10 to 90% rh, non-condensing
Humidity range
2014/30/EU
EMC
2014/35/EU
LVD
1995/5/EC
R&TTE:
Class V (+3%), (EU) 811/2013
ErP
Honeywell, declares that this thermostat is in compliance
with the essential requirements and other relevant
provisions of Directive 2014/53/EU
3
LYRIC T6 SMART THERMOSTAT
2
C
o
C
o
LYRIC-T6-EN0H 8603 NL01 R1216