Dell Precision 3930 Rack Service Manual page 41

Hide thumbs Also See for Precision 3930 Rack:
Table of Contents

Advertisement

d Remove the thermal grease from the processor using a clean lint free cloth.
Installing the processor
NOTE:
Insure pin 1 indicator of the processor is aligned with the pin 1 indicator on the system board.
1
Place the processor on the socket such that the slots on the processor align with the socket keys [1].
2
Close the processor shield by sliding it under the retention screw [2].
3
Lower the socket lever and push it under the tab to lock it [3].
4
Use the thermal grease syringe included with the processor kit. Apply the grease in a spiral design on top of the processor [4].
CAUTION:
Applying too much thermal grease can result in excessive grease coming in contact with and contaminating the
processor socket.
NOTE:
The thermal-grease is intended for one-time use only. Dispose of the syringe after you use it.
5
Install the:
a
Heat sink
b
Air duct
c
Top cover
6
Follow the procedure in
After working inside your
computer.
Removing and installing components
41