4.-OPERATION

Filling up. Open the shut-off valve once the immersion heater has been installed.Open the hot water
taps.Water appears as soon as the unit fills up completely.Close the taps and check the system for
leaks.
Do not connect the immersion heater to the mains until you are sure it is full.
Electric connection. Plug it into the mains and press the main power switch to turn the appliance on.A
light flashes when the heating element is working.
The thermostat re-activates the heating element after a certain amount of hot water has been used.
Setting water temperatures. The dial on the thermostat can be used to adjust the hot water
temperature between approximately 30 ºC (minimum position) and 75 ºC (maximum position).
E Position. (Energy saving).The water reaches a temperature of around 55 ºC.Heat losses are
minimum in this position and the formation of lime deposits are practically reduced.
It is recommended to have the water heater always plugged into the mains, as the thermostat will only
run the unit when necessary to keep the water at the selected temperature.
The polyurethane
insulation foam means that any heat loss will be insignificant.
Draining the unit. The heater should be drained if it is not to be used for extended periods of time and
if there is any risk of freezing pipes at the premises where it is installed.The heater can be drained
using the safety valve.Always remember to:
- Unplug the unit.
- Close the water inflow valve.
- Open the hot water tap.
Unplug the water heater and contact the Technical Assistance Service is you see any continuous steam
or boiling water coming out of the drain or when you open a tap.

5.- MAINTENANCE

IMPORTANT: Once a month check that the safety unit is not blocked.Do this by turning it to the
drainage position.If it is blocked, it must be replaced by a new one.
Every two years a technician needs to remove any scaling on the element. The warranty does not
cover any damages caused if this service is not carried out.
Any overheating by a possible thermostat failure is protected by the safety cut-out device, which stops
both phases and the immersion heater has no power supply.If this happens, contact our After-Sales
Service for the unit to be repaired.
Unplug the unit and leave it to cool and then clean it by wiping the unit with a soft cloth or damp
sponge.
Do not use solvents or abrasive products. Never submerge the immersion heater in water.
This water heater has been manufactured as part of a quality assurance system and using
environmentally-friendly processes.