Download Print this page

Rechner Sensors SW-600-M12/28-S Operating Instructions Manual page 11

Sw-600 series flow sensors

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Adjustment
The desired switching point can be adjusted by means of the 270° potentiometer on the sensor head.
Note: Please make the adjustment at constant flow only!
When the adjusted switching point is achieved the LED display changes colour from green to red or reverse
and there is also a change of the switching state of the switching output (NO).
Technical data SW-600-...-S
Technical data
Measuring range, depended on material
Repeat accuracy
Switching point
Type
Art.-No.
Process connection
Operating voltage (U
)
B
switching outputs
No-load current (I
)
o
Response- time
Temperature gradient
Operating pressure
Permitted ambient temperature
Display
Degree of protection IEC 60529
Connection
Material in contact with medium
Housing
Lid
Short circuit protection
Reverse polarity protection
Connection fig. 3
Potentiometer maximum left
Potentiometer maximum right
SW-600-M12/28-S
544 200
M 12 x 1
Galvanic separated, relay contact (normally open), max 200 mA
Dimension table
„A"
M 12 x 1
G 1/4"
G 1/2"
=
lowest sensitive
=
highest sensitivity
1 - 300 cm / s (H
1 %
Adjustable
SW-600-G1/4"/28-S
544 220
G 1/4"
24 V AC / DC ± 10 %
Typ. 60 mA
Typ. 2 s
Typ. 4 K / s
200 bar
0...+70 °C
LED red / green (red < limit value ,green > limit value)
IP 67
Plug-in connector M 12 x 1, 4 pole
Stainless steel no. 1.4571 (VA)
Stainless steel no. 1.4504 (VA)
PA 6.6
Yes
Yes
„B"
„C"
28
12
28
12
29,6
13,6
O: 150 cm / s)
2
SW-600-G1/2"/28-S
544 240
G 1/2"
Dimension fig. 4
11

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Sw-600-g1/2/28-sSw-600-g1/4/28-s