Terminal assignment supply voltage (operating voltage)
X 1
X 2
Terminal assignment low voltage (operating voltage)
X 1
X 2
Terminal assignment of the potential-free contact and of the external test
X 1
X 2
BEKOMAT® 32U
Power supply
X 3
 
X 1.1 L/+
X 1.2 N/-
L = Outer conductor
N = Neutral conductor
Power supply
X 3
 
X 1.1 L/+
X 1.2 N/-
Fault indication/potential-free contact:
X 3
 
X 2.1 n.o.
X 2.2 com.
X 2.3 n.c.
n.c. - com. closed in the event of malfunction or power failure
n.o. - com. closed during normal operation
(closed current principle)
The contacts X2.1 - 2.3 are potential-free.
External test / remote control:
X 3.1 external test (IN1)
X 3.2 GND
Contacts connected = test active = discharge
Contacts open = test inactive
The contacts X 3.1 -3.2 are not potential-free.
 