Mitsubishi Electric MELSEC Q Series Programming Manual page 103

Structured. fundamentals
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Category
Character string
Application instruction
Application instructions such as DMOD, PCHK, INC(P)
in GX Works2
For details, refer to the following.
• QCPU (Q mode)/LCPU
 MELSEC-Q/L Programming Manual (Common
Instruction)
 MELSEC-Q/L Structured Programming Manual
(Common Instructions)
• FXCPU
 FXCPU Structured Programming Manual [Basic &
Applied Instruction]
 FXCPU Structured Programming Manual [Application
Functions]
SFC instruction
SFCP, SFCPEND, BLOCK, BEND, TRANL, TRANO,
TRANA, TRANC, TRANCA, TRANOA, SEND, TRANOC,
TRANOCA, TRANCO, TRANCOC, STEPN, STEPD,
STEPSC, STEPSE, STEPST, STEPR, STEPC, STEPG,
STEPI, STEPID, STEPISC, STEPISE, STEPIST, STEPIR,
TRANJ, TRANOJ, TRANOCJ, TRANCJ, TRANCOJ,
TRANCOCJ
ST code body
RETURN, IF, THEN, ELSE, ELSIF, END_IF, CASE, OF,
END_CASE, FOR, TO, BY, DO, END_FOR, WHILE,
END_WHILE, REPEAT, UNTIL, END_REPEAT, EXIT, TYPE,
END_TYPE, STRUCT, END_STRUCT, RETAIN,
VAR_ACCESS, END_VAR, FUNCTION, END_FUNCTION,
FUNCTION_BLOCK, END_FUNCTION_BLOCK, STEP,
INITIAL_STEP, END_STEP, TRANSITION,
END_TRANSITION, FROM, TO, UNTILWHILE
Function name in
Function names in application functions such as AND_E,
application function
NOT_E
Function block name
Function block names in application functions such as CTD,
in application function
CTU
Symbol
/, \, *, ?, <, >, |, ", :, [, ] , , , =, +, %, ', ~, @, {, }, &, ^, ., ', tab
character
;
!, #, $, `
Date and time literal
DATE, DATE_AND_TIME, DT, TIME, TIME_OF_DAY, TOD
Others
ACTION, END_ACTION, CONFIGURATION,
END_CONFIGURATION, CONSTANT, F_EDGE, R_EDGE,
AT, PROGRAM, WITH, END_PROGRAM, TRUE, FALSE,
READ_ONLY, READ_WRITE, RESOURCE,
END_RESOURCE, ON, TASK, EN, ENO, BODY_CCE,
BODY_FBD, BODY_IL, BODY_LD, BODY_SFC, BODY_ST,
END_BODY, END_PARAMETER_SECTION,
PARAM_FILE_PATH, PARAMETER_SECTION, SINGLE,
RETAIN, INTERVAL
String that starts with
Such as K1AAA
K1 to K8
Address
Such as %IX0
Statement in ladder
;FB BLK START, ;FB START, ;FB END, ;FB BLK END, ;FB
language
IN, ;FB OUT, ;FB_NAME;,INSTANCE_NAME, ;FB,
;INSTANCE
Common instruction
Such as MOV
Windows reserved
COM1, COM2, COM3, COM4, COM5, COM6, COM7,
word
COM8, COM9, LPT1, LPT2, LPT3, LPT4, LPT5, LPT6,
LPT7, LPT8, LPT9, AUX, CON, PRN, NUL
*1 Functions cannot be used.
*2 Whether to handle a device name indexed with ZZ device as a reserved word depends on the parameter setting.
When Z device is specified for 32-bit index setting: Not handled as a reserved word
When ZZ device is specified for 32-bit index setting: Handled as a reserved word
*3 Applicable for Simple projects without labels only.
(1)
Appendix 2 Character Strings That Cannot Be Used in Label Names and Data Names
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
*1
*1
A
*1
*3
APPX
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec f seriesMelsec l series

Table of Contents