Emerson Bettis RGS F Series Installation, Operation And Maintenance Manual page 9

Double-acting actuators
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
RGS011110-2 Rev. 0
Piping Guidelines:
Figure 4
P1
P1
Installation
Both end cap pressure ports (P1 and P2) and both base plate pressure ports
(P3 and P4) must be utilized for proper operation.
P1 and P2 are typically connected and powered by a single air pathway.
P3 and P4 are typically connected and powered by a single air pathway.
P5 is a breather port that should be fitted with a filter or strainer.
On double-acting models, P5 may also be plugged without affecting
actuator operation.
P3
P3
P4
P5 (2)
P4
P5 (2)
Section 2: Installation
April 2016
P2
P2
6

Advertisement

Table of Contents
loading

Table of Contents