RGS011110-2 Rev. 0
10.
Table 3�
Cylinder Size (In)
Figure 9
1
3
1
3
5
5
3
7
3
5
11
3
7
9
Maintenance
Secure the end cap with the tie rod hex nuts you removed in step two.
Hand tighten, and then torque the hex nuts to half and then full values
according to the table below using the pattern designated.
6
8
10
12
16
20
24
4
4 Bolt
Pattern
2
6
6 Bolt
4
Pattern
2
1
8
4
8 Bolt
Pattern
6
7
2
9
1
6
10 Bolt
4
Pattern
8
10
2
6
1
10
8
12 Bolt
Pattern
4
12
5
2
Section 4: Maintenance
Ft-Lbs
15
35
35
35
56
58
87
April 2016
Nm
20
48
48
48
76
79
118