Viking FXI-1A Product Manual page 6

Fxo / fxs / telecom smart paging interface interface your paging system with virtually any telecom or ip phone system
Table of Contents

Advertisement

A. DIP Switch Programming (* factory default setting)
Switch
5
5
4
4
3
3
2
2
1
1
B. POT Programming (Shown at factory default setting)
Page Time Out
(seconds)
20
10
40
5
60
Disabled
Silence Time Out
(seconds)
5
2.5
10
Disabled
NOTE: If both the Page Time Out POT and Silence Time Out POT are turned to the "Disabled" position, and if
the phone system does not provide a CPC or Busy Signal, the FXI-1A will appear as if it is locked up. In actuality,
the FXI-1A simply does not have anything to tell it the page has ended. When this happens, the only way to clear
the ongoing page is to power down the unit by disconnecting the power and/ or disconnecting it from the ringing
station. Be sure to move the Page and Silence Time Out POTS from the "Disabled" position before reconnecting.
C. Talk Battery Switch (FXS vs FXO)
1. FXS
An FXS port is an analog output RJ11 port just like a station port on a phone system or PABX extension. It
provides talk battery, dial tone and ring voltage. In the FXS mode, the FXI-1A is triggered by ring voltage to
seize the line, it is then powered by the talk battery being provided, so the supplied 12VDC power supply is
not needed.
2. FXO
An FXO port is an analog input RJ11 port just like a POTS trunk input on a PABX or key system. An FXO port
receives talk battery and ring voltage. In the FXO mode, the FXI-1A provides 30V talk battery to connect to
6
an FXO port, trunk input, or plain analog phone.
Position
Description
ON
Enables Page Port Operation
OFF*
Disables Page Port Operation
ON
Enables Vox Mode
OFF*
Disables Vox Mode
ON
Lower Vox Sensitivity
OFF*
Normal Vox Sensitivity
ON
Enables Busy Detection Disconnect
OFF*
Disables Busy Detection Disconnect
ON*
Enables the Pre-Page Alert Tone - a High tone before the page
OFF
Disables the Pre-Page Alert Tone
Internal View of the FXI-1A
Programming
Master Volume Control
ON
MIN
MAX
OFF
Note: DIP Switches shown
in factory default settings.
Enable Page Port Operation
Enable VOX Mode
VOX Sensitivity
Enable Busy Detect
Enable Pre-page Alert Tone
Talk Battery Switch
FXS
FXO