MARKING OF STRIKE POSITION
P/n
Mark Centre of latch on
the door frame
• Ensure any rebate strips or door stops are fitted before proceeding.
To enable the Electric strike to be located in the door frame, first
mark the position of the Door Latch front face on the door frame with the
door in the closed position.
• Mark where centre of latch meets door frame:
- For new installations, mark frame where front of latch touches
the door frame at the midpoint of the latch bolt.
- For retrofit installations, remove existing strike plate and ensure that
latch fits into and is centred in existing hole.
4mm
• Using the markout as a guide, neatly chisel out the recess for the strike .
MORTICING REBATE
92mm
ES150 SERIES ELECTRIC STRIKE
INSTALLATION INSTRUCTIONS
33
Align the centre hole on the strike over the
marked line on the door frame.
• Centrally locate the strike in the marked position, lining up both the
centre hole on the strike and the marked frame.
Position the strike hard up against the door frame.
• Hold the strike firmly in place and mark around the edge .
• Making sure the drill is perpendicular to the frame, drill three pilot holes
using the strike as a template.
CHANGING MODE OF LOCK OPERATION
Long Pin
Short Pins
Power to Open
(Fail-Secure)
Fig 1
To change electric strike's mode of lock operation, remove brass screw
from top of strike body.
Invert strike and carefully release the small spring and 3 locking pins
(2 x Short pin, 1 x Long pin).
Re-insert pins in the manner shown for the desired mode of lock
operation (Power to Open / fail Secure): see Fig. 1; (Power to Lock / fail safe):
see Fig. 2, followed by replacing the spring. Screw in the brass screw to
strike body. This will secure the spring and locking pins.
POSITIONING OF STRIKE
Small End of
Spring
Power to Lock
(Fail-Safe)
Fig 2
Short Pins
Long Pin