DTC 217-ECT Higher Than Expected Stage 2
Diagnostic Aids
• If the "ECT High Voltage" fault is also present, follow the troubleshooting procedures for that fault as it may have
caused "ECT Higher Than Expected 2".
• If the cooling system utilizes an air-to-water heat exchanger (radiator) and fan:
–
Check that the radiator has a proper amount of ethylene glycol/water and that the radiator is not leaking
–
Ensure that there is no trapped air in the cooling path
–
Inspect the cooling system (radiator and hoses) for cracks and ensure connections are leak free
–
Check that the fan is operating properly
–
Check that the thermostat is not stuck closed
• If the cooling system utilizes a water-to-water heat exchanger:
–
Check that the heat exchanger has a proper amount of ethylene glycol/water and that the heat exchanger is
not leaking
–
Ensure that there is no trapped air in the cooling path
–
Inspect the cooling system (radiator and hoses) for cracks and ensure connections are leak free
–
Check that the raw water pickup is not blocked/restricted by debris and that the hose is tightly connected
–
Check that the thermostat is not stuck closed
–
Check that the raw water pump/impeller is tact and that it is not