4
Indoor passive infrared detector
Product code
2CSYD0102B
Technical specifications
APPLICATION SCOPE
Security
COMMUNICATION
Transmission in FM 868.3 MHz
TECHNOLOGY
RANGE IN FREE AIR
300 m
POWER SUPPLY
Lithium battery 3 V – 1.4 Ah lasting 4
years.
Operation is guaranteed for 30 days from
the low battery notification
DETECTION ELEMENTS
1 IR sensor with Fresnel lens
PROGRAMMING ELEMENTS
1 jumper for test
1 jumper for pulse counting
SIGNAL ELEMENTS
1 red LED
Low battery in the control unit
ANTI-TAMPERING PROTECTION Tamper
Additional data provided by the manufacturer
USAGE TEMPERATURE
-5 ... + 45 °C
USAGE RELATIVE HUMIDITY
Max 95% max (non-condensing)
USAGE ENVIRONMENT
Indoor (sheltered and dry places)
INSTALLATION
Free
SIZES (L x H x W)
70 x 114 x 76 mm
WARNING! Installation must be carried out only by a
qualified electrician
Package contents
no. 1 Indoor passive infrared detector
no. 1 Lithium battery 3 V – 1.4 Ah
no. 2 Self-tapping cross-recessed screws 2.9 x 27 mm
no. 2 Screw anchors ∅ 5 mm
no. 1 Manual
EC Declaration of Conformity
ABB S.p.A., with registered office in Milan - via Vittor Pisani 16,
declares under its own responsibility that the device with product
code
2CSYD0102B
meets
the
essential
electromagnetic
compatibility and security requirements contained in the Directive
R&TTE 1999/5/EC and in the EC Low Voltage Directive
2006/95/CE, as it was designed and manufactured in compliance
with the following harmonized standards: EN 300 220, EN 50130-
4, EN 50131-1, EN 50131-2-2, EN 50131-5-3.
ABB S.p.A. reserve the right to
change the product described in
this manual at any time and
without any advance notice.
ABB S.p.A. - ABB SACE Division
For
further
information:
Viale dell'Industria, 18
http://bol.it.abb.com,
20010 Vittuone (MI) – Italy
DomusTech section or call the
free-phone
Phone: 02.9034.1
Telefax: 02.9034.7609
Printed in Italy
Manual code 2CSM600503D0201 rev 00
2CSYD0102B
Indoor passive infrared
EN
Installation manual
Installation
The installation procedure encompasses the following steps:
1) Device fixing.
2) Operation
settings
(wide
coverage and standard/corridor for \).
3) Power supply and programming.
4) Completion and test.
1. Device fixing
INSTRUCTIONS RELEVANT TO POSITIONING
The device shall be installed:
•
at a height of 240 cm above the ground or at a height of 90
cm in order to create a corridor for pets (standard heights can
be changed);
•
far from heat sources and from direct sunlight;
•
far from electromagnetic sources (e.g. electricity meters,
electric engines);
•
at a distance of at least 1.5 meters from fluorescent lights;
•
by avoiding to direct the detector towards moving objects
(e.g. curtains);
•
by avoiding to direct the detector towards reflecting objects
that could change the coverage area.
at
Figure 1 shows the IR coverage diagrams in flat view and in
number
height view (standard settings and corridor settings for pets)
when the detector is adjusted for a wide coverage angle.
Figure 2 shows similar coverage diagrams related to the detector
adjusted for a long-distance coverage.
General description
detector
The indoor passive infrared detector detects the presence of
intruders in the controlled area.
The detector can be configured in order to provide a wide
coverage angle or a long-distance coverage by keeping the same
sensitivity.
The sensor can operate also in presence of pets.
coverage
angle/long-distance
- 2 -
- 1 -
Figure 1
- 3 -