13.

SAFETY DEVICES

Current fuse (Main PCB)
Current fuse (Main PCB)
Circuit protection
Current fuse (Main PCB)
Protector (Filter PCB)
Fan motor protection
Thermal protector
Thermal protection program
(Compressor temp.)
Compressor
protection
Thermal protection program
(Discharge temp.)
Thermal protection program
(Heat exchanger temp.)
High pressure
protection
Pressure sensor
Low pressure
Pressure sensor
protection
Protection form
Cooling
Heating
Cooling
- (02 - 16) -
Model
AO
G60LATT
250V 5A
250V 3.15A
250V 10A
500V 15A
OFF:150±15°C
ON:120±15°C
OFF:110°C
ON:80°C
OFF : 115°C
ON : After 7 minutes
OFF : 68°C
ON : 63°C
OFF:4.1MPa
ON : After 3 minutes
OFF:0.12MPa or less (for 5 minutes)
ON : After 7 minutes