Installation Instructions Original Instructions ControlLogix ControlNet Scanner Module Catalog Numbers 1756-CNB, 1756-CNBK, 1756-CNBR, 1756-CNBRK Topic Page Set the Module Network Address Determine Module Slot Location Install the Module Connect to the ControlNet Network Connect to the Network with a Tap...
Page 2
ControlLogix ControlNet Scanner Module ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Page 3
ControlLogix ControlNet Scanner Module Prevent Electrostatic Discharge ATTENTION: Read this document and the documents that are ATTENTION: This equipment is sensitive to electrostatic discharge, listed in the Additional Resources section about installation, which can cause internal damage and affect normal operation.
Page 4
ControlLogix ControlNet Scanner Module North American Hazardous Location Approval The following information applies when operating this equipment in hazardous Informations sur l’utilisation de cet équipement en environnements dangereux. locations. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en Products marked "CL I, DIV 2, GP A, B, C, D"...
ControlLogix ControlNet Scanner Module Set the Module Network Address Chassis Slot Numbering Slot 0 Slot 2 Use your fingers or a small screwdriver to set the network address Slot 1 Slot 3 switches for the module. For modules in a standalone chassis, you must specify a unique ControlNet network address;...
ControlLogix ControlNet Scanner Module Follow these steps to install the module. The figure shows an example ControlNet network using redundant media. 1. Align the circuit board with top and bottom guides in the chassis. ControlNet Network 1756-CNBR, 1756-CNBRK Module 2. Slide the module into the chassis.
Page 7
ControlLogix ControlNet Scanner Module 2. Connect the tap’s straight or right-angle connector to the 3. Apply power to the module and check module status. module BNC connector. Use the following flowchart as a guide. If Your Node Supports Connect The Tap’s Connector...
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Automation, ControlLogix, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400...