Installation Instructions Original Instructions ControlLogix DeviceNet Scanner Module Catalog Numbers 1756-DNB, 1756-DNBK Topic Page About the Module Determine Module Slot Location Change Module Settings Install the Module in the Chassis Specifications Additional Resources ControlLogix® DeviceNet scanners are devices that are used with various programmable controllers on the DeviceNet network.
Page 2
ControlLogix DeviceNet Scanner Module ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Page 3
ControlLogix DeviceNet Scanner Module North American Hazardous Location Approval The following information applies when operating this equipment in hazardous Informations sur l’utilisation de cet équipement en environnements dangereux. locations. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en Products marked "CL I, DIV 2, GP A, B, C, D"...
Page 4
ControlLogix DeviceNet Scanner Module Prevent Electrostatic Discharge WARNING: Special Conditions for Safe Use: ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. • This equipment shall be mounted in an ATEX Zone 2 certified...
ControlLogix DeviceNet Scanner Module About the Module Use this figure to identify the external features of the module. Top View Front View Backplane Connector Front Panel USB Port DeviceNet Port Side View 31713-M Determine Module Slot Location Install the module in any slot in the ControlLogix chassis. You can install multiple 1756-DNB scanners in the same chassis.
Page 6
ControlLogix DeviceNet Scanner Module Set the Rotary Switch Set the Communication Rate The 1756-DNB scanner supports the following DeviceNet network Use the communication (data) rate rotary switch to change the communication rates: communication rate. • 125 Kbps IMPORTANT For ease of access, remove the module from the chassis before •...
ControlLogix DeviceNet Scanner Module Switch Settings Restore the Factory Default Settings The out-of-box reset clears the scanlist (including ADR configuration recovery files) and return all software setting attributes to their default Front of Top of Module values. Module Follow this procedure to restore the factory default communication rate and node address.
Page 8
ControlLogix DeviceNet Scanner Module Connect the Module to the DeviceNet Network Attach the connector to the module DeviceNet port as shown. IMPORTANT For detailed DeviceNet connection information, see the Tighten the screws on the connector as needed. DeviceNet Media Design and Installation Guide, publication DNET-UM072.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Automation, ControlLogix, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400...