Maipu SM6600-08-MF Installation Manual

Routing switch, mypower s6600 series

Advertisement

Quick Links

MyPower
MyPower
MyPower
MyPower S6600
Maipu Communication Technology Co., Ltd
No. 16, Jiuxing Avenue
Hi-tech Park
Chengdu, Sichuan Province
People's Republic of China - 610041
Tel:
Tel:
Tel:
Tel: (86) 28-85148850, 85148041
Fax:
Fax:
Fax: (86) 28-85148948, 85148139
Fax:
URL:
URL:
URL: http: //
URL:
www.maipu.com
Email:
overseas@maipu.com
overseas@maipu.com
overseas@maipu.com
overseas@maipu.com
S6600
S6600
Series
Series
S6600 Series
Series Routing
Routing
Routing
Routing Switch
Installation
Installation
Installation
Installation Manual
Switch
Switch
Switch
Manual
Manual
Manual
V1.0

Advertisement

Table of Contents
loading

Summary of Contents for Maipu SM6600-08-MF

  • Page 1 Routing Switch Switch Installation Manual Installation Manual Installation Installation Manual Manual V1.0 Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People’s Republic of China - 610041 Tel: Tel: Tel: Tel: (86) 28-85148850, 85148041 Fax:...
  • Page 2 The information in this document is subject to change without notice. In no event shall Maipu be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however...
  • Page 3 � Commissioning engineers � Field maintenance engineers � System maintenance engineers Conventions Conventions Conventions Conventions Conventions of screen output format: Format Format Format Format Description Description Description Description Screen Represents the output information of the screen print copyright©2015 Maipu All rights reserved.
  • Page 4 { x | y | ... } Asterisk marked braces enclose a set of required syntax choices separated by vertical bars, from which you select at least one. copyright©2015 Maipu All rights reserved.
  • Page 5 Routing Switch Configuration Manual Obtaining Obtaining Obtaining Obtaining Documentation Documentation Documentation Documentation You can access the most up-to-date Maipu product documentation on the World Wide Web at www.maipu.com. Technical Technical Support Support Technical Technical Support Support � Technical supporting hotline: 400-886-8669 �...
  • Page 6 We appreciate your comments. Revision Revision Revision Revision Records Records Records Records Version Version Version Version Revision Revision Revision Revision Date Date Date Date Revised Revised Revised Revised Content Content Content Content V1.0 2015-01-08 First formal release copyright©2015 Maipu All rights reserved.
  • Page 7 ······························································································································ 2-4 ANDLING AFETY 2.2.5 L ·····································································································································2-5 ASER AFETY 2.3 O O O O -P -P -P -P I I I I ········································································································ ········································································································ ········································································································ ········································································································2-5 ACKAGE ACKAGE NSPECTION NSPECTION ACKAGE ACKAGE AND NSPECTION NSPECTION copyright©2015 Maipu All rights reserved.
  • Page 8 IBER 4.2.4 A ·························································································· 4-15 CCESS ETWORK VIA TANDBY ABLE 4.3 H H H H M M M M ················································································································· ················································································································· 4-16 4-16 ················································································································· ·················································································································4-16 4-16 ARDWARE ARDWARE ANAGEMENT ANAGEMENT ARDWARE ARDWARE ANAGEMENT ANAGEMENT viii copyright©2015 Maipu All rights reserved.
  • Page 9 ············································································································6-12 HANGE HASSIS ILTER 6.2 D D D D M M M M D D D D ································································································ ································································································ 6-14 6-14 ································································································ ································································································6-14 6-14 AINTENANCE AINTENANCE AINTENANCE AINTENANCE OF OF THE EVICE EVICE EVICE EVICE copyright©2015 Maipu All rights reserved.
  • Page 10 B Specifications of General Interfaces······································································································ B-17 B1 Console Port Attribute··························································································································B-17 B2 10Base-T/100Base-TX/1000Base-T-RJ45 Electrical Port Attributes·················································· B-17 B3 10Base-T/100Base-TX/1000Base-T RJ45 POE+ Interface Attributes················································ B-18 B4 1000Base-X-SFP Optical Port Attributes·····························································································B-18 B5 10GBase-SR/LR SFP+ Optical Port Attributes····················································································B-19 B6 40GBase-SR4 QSFP+ Optical Port Attributes·····················································································B-19 copyright©2015 Maipu All rights reserved.
  • Page 11 D2 Requirements for Power Supply············································································································D-4 D2.1 AC Power Supply Requirement········································································································· D-4 D2.2 AC Power Supply Suggestions···········································································································D-5 D2.3 DC Power Supply Requirement········································································································· D-6 D2.4 DC Power Supply Suggestions···········································································································D-6 E Device Grounding Specification and Protection······················································································ E-1 E1 Device Grounding Specifications···········································································································E-1 copyright©2015 Maipu All rights reserved.
  • Page 12 E2.1 General Requirement of Lightning Protection Wires·········································································· E-4 E2.2 Installation Method of Cable Wiring··································································································· E-5 E2.3 Equipotential Connection Requirement and Method·········································································· E-7 F Wiring Recommendation·························································································································· F-1 F1 Wiring Recommendation during Installation··························································································F-1 F2 Cable Binding Recommendation············································································································ F-2 G Environmental Substance Statement······································································································· G-1 copyright©2015 Maipu All rights reserved.
  • Page 13 MPU: Main Processing Unit control card. For the specifications, refer to Specifications of MPU Card. � SFU: Switching Fabric Unit switch card. For the specifications, refer to Specifications of SFU Card. � LPU: Line Processing Unit user network interface card. For the specifications, copyright©2015 Maipu All rights reserved.
  • Page 14: Sm6600-04-Mf···································································································································1-2

    D I A G R A M 1.Device outlet 2. Mounting ear 3.Power module slots (0-3) 4. Anti-static wrist socket 5. LPU card slots ( 0-3) 6.SFU card slots (0-1) 7.MPU card slots (0-1) 8. Device head copyright©2015 Maipu All rights reserved.
  • Page 15 SM6600-08-MF 1.1.2 1.1.2 SM6600-08-MF SM6600-08-MF The dimension of SM6600-08-MF is 444mm×465mm×711mm (W×D×H). The front appearance diagram of SM6600-08-MF is as shown in Figure 1-3 and the back appearance diagram is as shown in Figure 1-4. copyright©2015 Maipu All rights reserved.
  • Page 16 D I A G R A M 1.Device outlet 2. Mounting ear 3.Power module slots (0-3) 4. Anti-static wrist socket 5. LPU card slots ( 0-7) 6.SFU card slots (0-1) 7.MPU card slots (0-1) 8. Device head or SIU card slot copyright©2015 Maipu All rights reserved.
  • Page 17 Fan module slot Power module fan outlet Grounding screw Card Card 1.2 MPU MPU Card Card MPU: Main Processing Unit control card The MPU card is the mandatory card in the SM6600 series routing switch and it copyright©2015 Maipu All rights reserved.
  • Page 18 Card Card SFU: Switching Fabric Unit switching card The SFU card is the switching network unit of the S6600 series routing switching, realizing the switching function of the service data between the LPU cards. When copyright©2015 Maipu All rights reserved.
  • Page 19 A P P E A R A N C E D I A G R A M D I A G R A M O F O F T H E T H E C A R D C A R D Captive screw Card extractor Status indicator Function port copyright©2015 Maipu All rights reserved.
  • Page 20 Card SIU: System Interface Unit system interface card The SIU card is used for SM6600-08-MF and one is optional. With the LCD panel and buttons, the user can query the product working status and indicate the system working status via the LED indicator.
  • Page 21 P O W E R M O D U L E M O D U L E M O D U L E M O D U L E Power switch Power status indicator DC power socket Installation handle copyright©2015 Maipu All rights reserved.
  • Page 22 � Support hot-swap: Replace the fan module without interrupting the switching running. � SM6600-04-MF and SM6600-08-MF use different models of fan modules respectively and cannot be in mixed use. 1.7.1 1.7.1...
  • Page 23 Module FAN-13A-01 fan module is the mandatory module of SM6600-08-MF and supports hot-swap. Each SM6600-08-MF has one FAN slot and should be installed with one FAN-13A-01 fan module so that the system can run normally. The diagram of the fan module is as follows:...
  • Page 24 S W I T C H S W I T C H C H A S S I S C H A S S I S C H A S S I S C H A S S I S copyright©2015 Maipu All rights reserved.
  • Page 25 Installation Preparations MyPower S6600 Series Routing Switch Installation Manual � Please keep the device air vent unblocked when the device runs. copyright©2015 Maipu All rights reserved.
  • Page 27: Installation Installation Installation Installation Preparations

    When the device is delivered, there is the packing list. Please confirm whether the accessories are complete and good according to the items in the packing list. If there is damaged or loss, please contact Maipu technical staff to change.
  • Page 28 For details, refer to D2 Requirements for Power Supply. � For the power consumption data of the switch, refer to A1 Specifications of Whole Device and Common Modules. copyright©2015 Maipu All rights reserved.
  • Page 29: Safety Precautions

    When closing the power, ensure that the neutral line and live line are disconnected. 2.2.3 2.2.3 Static Static Safety Safety 2.2.3 2.2.3 Static Static Safety Safety To avoid the static from damaging the electronic parts of the switch, we need to take the anti-static measures. copyright©2015 Maipu All rights reserved.
  • Page 30 S T A T I C S T A T I C S T A T I C W R I S T W R I S T W R I S T W R I S T copyright©2015 Maipu All rights reserved.
  • Page 31 Otherwise, the laser may damage your eyes. Open-Package Inspection 2.3 Open-Package Open-Package Open-Package and and Inspection Inspection Inspection S6600 series routing switch adopts the carton packaging. The packaging of one copyright©2015 Maipu All rights reserved.
  • Page 32 In the independent board packing box, only the packing box of the MPU card contains the memory. � Keep the accessories and memory in the accessory box and do not lose. � The MPU card can be used normally only when being installed with the copyright©2015 Maipu All rights reserved.
  • Page 33 S T R A I G H T E N I N G T H E T H E T H E T H E T O N G U E T O N G U E T O N G U E T O N G U E copyright©2015 Maipu All rights reserved.
  • Page 34 O P E N I N G T H E T H E B O X B O X Step 5: Straightening the tongues under the box coaming and remove the box coaming, as shown in the following figure. copyright©2015 Maipu All rights reserved.
  • Page 35 C O A M I N G C O A M I N G C O A M I N G Step 6: Remove the protection EPE and packing bag around the device, and then you can take out the device. copyright©2015 Maipu All rights reserved.
  • Page 37 Installation Preparations Preparations Preparations � SM6600-04-MF is 1U high, SM6600-08-MF is 16U high, and reserve enough installation space before installing the device. � When installing S6600 series routing switch, check the maximum load capacity of the cabinet and bracket, the machine room floor in advance (for...
  • Page 38 C A B I N E T C A B I N E T C A B I N E T C A B I N E T Square hole column Column in front of the cabinet copyright©2015 Maipu All rights reserved.
  • Page 39 R A I L R A I L The following takes the 19-inch standard cabinet as an example to describe the installation process of the guide rail. The installation steps of the guide rail are as follows: copyright©2015 Maipu All rights reserved.
  • Page 40 The content of this section is just for reference. Please subject to the actuality. � To install multiple devices on the cabinet, please install the heavy device under the cabinet. copyright©2015 Maipu All rights reserved.
  • Page 41 Step 2: Install the floating nuts at the marked location (each installation hole on the mounting ears is installed with one floating nut correspondingly). copyright©2015 Maipu All rights reserved.
  • Page 42 The guide rail or tray plays a role in load-bearing. The diagram of installing the switch to the 19-inch standard cabinet is as follows: copyright©2015 Maipu All rights reserved.
  • Page 43 � The mounting ears cannot play a role in load-bearing. Prohibit not installing guide rail or tray, but just using the mounting ears to bear the switch. copyright©2015 Maipu All rights reserved.
  • Page 44 3.2 Device Device Grounding Grounding � To ensure the safety of the personnel and equipment, the device should be well-grounded and the resistance between the device chassis and the ground should be smaller than 1Ω. copyright©2015 Maipu All rights reserved.
  • Page 45 � Fire hose and lightning rod grounding of the building are not the proper grounding location; the grounding wire of the switch should be connected to copyright©2015 Maipu All rights reserved.
  • Page 46 Overload auto protector Automatically reset after overload closed, load recovers Standard socket Connect to the machine room power via the power cable � The power surge protector is not provided with the device and the user can copyright©2015 Maipu All rights reserved.
  • Page 47 IN end and connect the transit cable connected to the switch to the OUT end). Meanwhile, check whether the display of the board indicator is normal. Step 4: Use the cable tie to bind up the cables. copyright©2015 Maipu All rights reserved.
  • Page 48 AC power of the switch reaches the better lightening protection effect via the external lightening equipment. � Before connecting the power cable, confirm that the power switch is OFF (only for the pluggable power). copyright©2015 Maipu All rights reserved.
  • Page 49 Step 3: Connect 0V, -48V, and grounding terminals on one side of the DC power cable respectively to the corresponding terminals on the power strip. Then, tighten the fixed screw and cover copyright©2015 Maipu All rights reserved.
  • Page 50 Installation � Before checking whether the installation is correct, please confirm that the power is closed, avoiding that the connection error damages the body or component. � Confirm that the ground wire is connected correctly. copyright©2015 Maipu All rights reserved.
  • Page 51 Installation Preparations MyPower S6600 Series Routing Switch Installation Manual � Confirm that the power module is installed. � Confirm that the MPU card, SFU card, LPU card, and power module are installed tightly. copyright©2015 Maipu All rights reserved.
  • Page 53 Insert the RJ45 of the console cable to the configuration serial port of the switch. Insert the other side DB-9 (hole) of the console cable to the 9-pin serial port socket of the PC (or laptop). The diagram of connecting the switch and PC via the console cable is as follows: copyright©2015 Maipu All rights reserved.
  • Page 54 HperTerminal, HperTerminal, HperTerminal, HperTerminal, the system displays the “Location Location Location Location information information information information” interface as shown in Figure 4-2. Fill in according to the red indication in the figure and click copyright©2015 Maipu All rights reserved.
  • Page 55 I N T E R F A C E I N T E R F A C E Step 3: On the Connection Connection Connection Connection Description Description Description Description interface, input the “Name Name Name Name”, such as test, and click OK copyright©2015 Maipu All rights reserved.
  • Page 56 Display the following “COM1 COM1 Properties Properties” interface, set the baud rate as 9600, data bit as 8, parity check as none, stop bit as 1, and data flow control as none, and click OK copyright©2015 Maipu All rights reserved.
  • Page 57 I N T E R F A C E test-Properties Setting Step 7: Display the following“test-Properties test-Properties test-Properties” interface, click Setting Setting Setting in the property window, select E E E E mulation mulation mulation mulation as VT100, and then click OK copyright©2015 Maipu All rights reserved.
  • Page 58 Power-on Power-on Power-on Check the switch before power-on: � The interface cables, power cables, and ground wires are connected correctly. � Power supply voltage meets the power requirement of the device. For details, copyright©2015 Maipu All rights reserved.
  • Page 59 **************************************************************************** MyPower (R) Operating System Software MyPower S6600 system image file (dc0: sp5b-g-6.6.5.1.4(28)-dbg.pck), version 6.6.5.1.4(28)(integrity), Compiled on Oct 31 2014, 04:04:05 Copyright (C) 2009 Maipu Communication Technology Co., Ltd. All Rights Reserved. MyPower S6600 Version Information System ID : 00017a43fe2a...
  • Page 60 Off: The MPU card works in the standby mode; Flash: The MPU card is the active card in all stacking devices. POWER (green) On: The power of the MPU card is normal; Off: The power of the MPU card copyright©2015 Maipu All rights reserved.
  • Page 61 On: The port data is set up; Flash: The port has data received and sent. SIU card status indicator SYSTEM (green) Flash: system works normally; Off/on: system works abnormally. ALARM (red and Red: The system has Critical copyright©2015 Maipu All rights reserved.
  • Page 62 Insert one side of the Ethernet twisted pair to the Ethernet RJ45 port of the switch. Step 2: Insert the other side of the Ethernet twisted pair to the RJ45 port of the device connected to the network. copyright©2015 Maipu All rights reserved.
  • Page 63: G Eneral

    Figure 4-11. Use the hands to hold the two sides of the SFP module and push it into the interface slot of the switch horizontally until the SFP module is close-contact with the slot (you can feel that the shrapnel at the top and bottom of the SFP module stuck the interface copyright©2015 Maipu All rights reserved.
  • Page 64: Sfp Module

    F I B E R F I B E R D U S T D U S T D U S T D U S T C A P C A P C A P C A P copyright©2015 Maipu All rights reserved.
  • Page 65 Before connecting fiber, first install the optical module to the switch and then insert the fiber connector to the optical module. The appearance of the general MPO fiber connector is as shown in the following figure. copyright©2015 Maipu All rights reserved.
  • Page 66 I G U R E I G U R E M O D U L E M O D U L E D I A G R A M D I A G R A M copyright©2015 Maipu All rights reserved.
  • Page 67 F I B E R D U S T D U S T D U S T C A P C A P C A P Step 3: Remove the dust cap of the QSFP+ module. copyright©2015 Maipu All rights reserved.
  • Page 68 DB-9 plug is connected to the DB-9 socket of the Modem. The connection steps are as follows: Step 1: Insert the RJ45 terminal of the console cable into the AUX port of the switch. copyright©2015 Maipu All rights reserved.
  • Page 69: Hardware Management

    The section contains the following contents: 4.3.1 View Software and Hardware Version Information of Switch 4.3.2 View System Environment Temperature Information 4.3.3 View Fan Status Information 4.3.4 View Power Module Status Information 4.3.5 View Backplane Status Information copyright©2015 Maipu All rights reserved.
  • Page 70: Version Information

    4.3.7 View SFU Card Status Information 4.3.8 View LPU Card Status Information 4.3.9 View Swappable Optical Module Information � This section takes SM6600-08-MF as an example to describe the viewing method. � The print information mentioned in the description of this section is just for reference.
  • Page 71 For example: switch#show environment Mpu 0 CPU temperature is 62°C Mpu 0 mainboard temperature is 32°C Mpu 1 CPU temperature is 64°C Mpu 1 mainboard temperature is 32°C Lpu 2 chip temperature is 58°C copyright©2015 Maipu All rights reserved.
  • Page 72 S H O W S Y S T E M S Y S T E M S Y S T E M S Y S T E M F A N F A N F A N F A N copyright©2015 Maipu All rights reserved.
  • Page 73 IN: The physically inserting times, such as 1 IERR: The physically error inserting times of the fan, such as: 0 OUT: The physically pull-out times, such as 0 OERR: The physically error pull-out times, such as 0 copyright©2015 Maipu All rights reserved.
  • Page 74 System Power Information (Power 1 - The power online information, such as: ONLINE) Power 0 - ONLINE Status The working status of the power module, such as Normal � Normal: The power module works normally copyright©2015 Maipu All rights reserved.
  • Page 75 MAC address information stored by the storage chip of the backplane, and other information. For example: switch#show system chassis System Chassis Information Device:0 (ONLINE) ---------------------------------------------------------------- Chassis Type: SM6600-08-MF(V2) Serial No.: 4424132181700001 Chassis-MAC-Group-0: 00017a43fe2a 00017a43fe2b 00017a43fe2c 00017a43fe2d copyright©2015 Maipu All rights reserved.
  • Page 76 MAC addresses; by default, they are: 000000000000 000000000000 000000000000 000000000000 000000000000 STATISTICS The swapping times of the backplane and the error swapping times, such as 1 IN, IERR, 0 OUT, 0 OERR indicates that the copyright©2015 Maipu All rights reserved.
  • Page 77 System Card Information(Mpu 0 - ONLINE) ---------------------------------------------------------------- Type: SM66-MPUB[0x35832001] Status: Start Ok Last-Alarm: Normal Card-Port-Num: Card-SubSlot-Num: Power-INTF-Status: Normal Power-Card-Status: Serial No.: 9983145380900026 Card-Name: SM66-MPUB Description: Power-RT-Infomation: Voltage-In: 5.11 V Hardware-Information: HW-State: 0 PCB-Version: 2 copyright©2015 Maipu All rights reserved.
  • Page 78 BytesAlloc = 207951144 bytes BlocksFree = 40 blocks BlocksAlloc = 11921 blocks MaxBlockSizeFree = 266338304 bytes SizeTotal = 1067749296 bytes DISK-On-Card-Information: DISK-Idx: 00 Type: Flash Status: Online DISK-State: SizeTotal = 32438272 bytes SizeFree = 7657472 bytes copyright©2015 Maipu All rights reserved.
  • Page 79 Power-INTF-Status The power status of the MPU card, such as Normal Power-Card-Status The power-on status of the MPU card, such as On Serial No MPU card serial number, provided by the device supplier, such 9983145380900026 copyright©2015 Maipu All rights reserved.
  • Page 80 CPU-On-Card-Information The CPU information on the MPU card CPU-Idx CPU serial number, such as: 00 Status CPU status, such as: Normal Core-Num CPU core quantity, such as: 0002 Core-State CPU core status information copyright©2015 Maipu All rights reserved.
  • Page 81 The total size of the memory, such as: 1067749296 bytes DISK-On-Card-Information The storage device information on the MPU card DISK-Idx The serial number of the storage device, such as: 00 Type The type of the storage device, such as: Flash copyright©2015 Maipu All rights reserved.
  • Page 82 For example: switch#show system sfu System Card Information(Sfu 0 - ONLINE) ---------------------------------------------------------------- copyright©2015 Maipu All rights reserved.
  • Page 83 Last-Alarm = Normal. CPU-On-Card-Information: < 1 CPUs> CPU-Idx: 00 Status: Normal Core-Num: 0001 Core-State: Core-Idx-00 Core-Status: 0000 Core-Utilization: 7% Temperature: Temperature-State: Temperature = 88.C Last-Alarm = Normal. MEM-On-Card-Information: <1 MEMs> MEM-Idx: 00 MEM-State: BytesFree = 33485652 bytes copyright©2015 Maipu All rights reserved.
  • Page 84 The port quantity of the SFU card; by default, it is 0. Card-SubSlot-Num The subslot quantity of the SFU card: The SFU card does not have the sub slot, so it is 0 by default. copyright©2015 Maipu All rights reserved.
  • Page 85 The PCB temperature alarm information of the SFU card, such as: Normal: The PCB temperature of the SFU card has no alarm CPU-On-Card-Information The CPU information on the SFU card CPU-Idx CPU serial number, such as: 00 copyright©2015 Maipu All rights reserved.
  • Page 86 The maximum idle block size, such as: 14660064 bytes SizeTotal The total size of the memory, such as: 133626592 bytes CMM-Information The CMM information on the SFU card Hardware-Type CMM hardware model; by default, it is 0000 copyright©2015 Maipu All rights reserved.
  • Page 87 For example: switch# show system lpu 2 System Card Information(Lpu 2 - ONLINE) ---------------------------------------------------------------- Type: SM66-48GET(V2)[0x2541a030] Status: Start Ok Last-Alarm: Normal Card-Port-Num: Card-SubSlot-Num: Power-INTF-Status: Normal Power-Card-Status: Serial No.: 4694124280100011 Card-Name: SM66-48GET(V2) Description: copyright©2015 Maipu All rights reserved.
  • Page 88 BytesAlloc = 128518556 bytes BlocksFree = 16 blocks BlocksAlloc = 2696 blocks MaxBlockSizeFree = 102760448 bytes SizeTotal = 267065072 bytes CMM-Information: Hardware-Type: 0000 Monitor-Version: 1.0.11 Software-Version: 2.0.139 ---------------------------------------------------------------- STATISTICS: 1 IN, 0 OUT, 0 IERR, 0 OERR copyright©2015 Maipu All rights reserved.
  • Page 89 LPU card name, such as: SM66-48GET(V2) Description The fields of the description information, configured by the user Power-RT-Infomation The realtime information of the LPU card power Voltage-In LPU card voltage, such as: 5.15V Hardware-Information LPU card hardware information copyright©2015 Maipu All rights reserved.
  • Page 90 Core-Idx-00 Core-Status CPU core status, such as: 0000 Core-Utilization CPU core utilization, such as2% Temperature CPU temperature Temperature-State CPU temperature status Temperature = CPU temperature, such as42.C Last-Alarm = CPU temperature alarm information, such copyright©2015 Maipu All rights reserved.
  • Page 91 IERR: The physically error inserting times of the LPU card, such as: 0 OUT: The physically pull-out times of the LPU card, such as 0 OERR: The physically error pull-out times of the LPU card, such as 0 copyright©2015 Maipu All rights reserved.
  • Page 92 DDMI function), such as -1.880231dBm RxPower(dBm) The receiving power of the optical module (only for the optical module supporting the DDMI function), such as -2.297373dBm Besides, you can use the following commands to view the details of the inserted copyright©2015 Maipu All rights reserved.
  • Page 93 Warning-Low(T/S) ----------------------------------------------------------------------------------------------------------- Temperature(C) 50.355469 90.000000(N) -10.000000(N) 85.000000(N) -5.000000(N) Voltage(V) 3.261800 3.600000(N) 3.000000(N) 3.500000(N) 3.050000(N) Tx Bias(mA) 6.578000 50.000000(N) 1.000000(N) 40.000000(N) 2.000000(N) Rx Power(dBm) -2.300322 0.999912(N) -13.098040(N) 0.000000(N) -12.097148(N) Tx Power(dBm) -1.879561 0.999912(N) -9.299622(N) 0.000000(N) -8.300319(N) copyright©2015 Maipu All rights reserved.
  • Page 94 Monitor parameters (only for the optical module supporting the DDMI function) � Temperature/Alarm-High/Alarm-low/Warning-High/ Warning-Low Temperature/alarm upper threshold/alarm lower threshold/warning upper threshold/warning lower threshold � Voltage/Alarm-High/Alarm-low/Warning-High/Warning-Low Voltage/alarm upper threshold/alarm lower threshold/warning upper threshold/warning lower threshold � Tx Bias/Alarm-High/Alarm-low/Warning-High/Warning-Low bias current/alarm upper threshold/alarm lower copyright©2015 Maipu All rights reserved.
  • Page 95 Field Field Description Description threshold/warning upper threshold/warning lower threshold � RxPower /Alarm-High/Alarm-low/Warning-High/Warning-Low optical power/alarm upper threshold/alarm lower threshold/warning upper threshold/warning lower threshold � TxPower /Alarm-High/Alarm-low/Warning-High/Warning-Low optical power/alarm upper threshold/alarm lower threshold/warning upper threshold/warning lower threshold copyright©2015 Maipu All rights reserved.
  • Page 97: Configuration System

    Check whether the board card is inserted correctly and whether the MPU card (control card) is damaged. Step 3: Check whether the configuration cable is connected to Console port of the MPU card (control card). copyright©2015 Maipu All rights reserved.
  • Page 98 Check whether the switch of the faulty power module is opened, at “ON”. Step 3: Check the connection of the power cable on the faulty power module; re-swap the power cable to confirm whether the power cable is loose. copyright©2015 Maipu All rights reserved.
  • Page 99 SM6600-04-MF has one fan slot. One FAN-7A-01 fan module should be installed so that the system can work normally. FAN-13A-01 fan module is the mandatory module of SM6600-08-MF and supports hot-swap. SM6600-08-MF has one fan slot. One FAN-13A-01 fan module should be installed so that the system can work normally.
  • Page 100 Connect the console port. View the specific boot information via the configuration terminal to locate the fault. If the fault cannot be removed via the above steps, please contact the agent or local technical engineers. copyright©2015 Maipu All rights reserved.
  • Page 101 Check whether the connection of the interface cable is correct. If the interface is RJ45 Ethernet port, refer to 4.2.1 Access Network via Ethernet Twisted Pair. If the interface is the optical interface, refer to 4.2.2 Access Network via LC Fiber 4.2.3 Access Network via copyright©2015 Maipu All rights reserved.
  • Page 102 6. Simple introduction of the taken troubleshooting steps You can contact the customer service via the customer service hotline and you can also search for help via the website or email. Customer service: 400-886-8669 Website: http://www.maipu.com E-mail: techsupport@maipu.com copyright©2015 Maipu All rights reserved.
  • Page 103 Installation Preparations MyPower S6600 Series Routing Switch Installation Manual copyright©2015 Maipu All rights reserved.
  • Page 105 When moving the power module, use the hands to support the bottom of the module parts. Do not hold the handles of the module to move. � The power module supports hot-swap and you can change the power when copyright©2015 Maipu All rights reserved.
  • Page 106 T H E P O W E R P O W E R M O D U L E M O D U L E Step 3: Put the removed power module on the anti-static mat or the packing box. copyright©2015 Maipu All rights reserved.
  • Page 107 Step 1: Wear the anti-static wrist and confirm that the anti-static wrist is well-grounded. Step 2: If there is the air baffle at the location for installing the board, please uninstall the air baffle first. copyright©2015 Maipu All rights reserved.
  • Page 108 I N S T A L L I N G T H E T H E T H E T H E C A R D C A R D C A R D C A R D copyright©2015 Maipu All rights reserved.
  • Page 109 Meanwhile, considering that the fan may be still running, do not out the hands into the fan module, preventing from being damaged. � Before changing, prepare the new fan module. After un-installing the fan copyright©2015 Maipu All rights reserved.
  • Page 110 The changing process of the fan module of S6600 series routing switch chassis is similar. The following takes SM6600-08-MF as an example. The changing steps are as follows: Step 1: Wear the anti-static wrists, use the cross screwdriver to loosen the captive screws on the fan module.
  • Page 111 C A R D C A R D S L O T S L O T S L O T S L O T CF card slot CF card extractor button CF card status indicator copyright©2015 Maipu All rights reserved.
  • Page 112 When the switch starts or the CF card indicator flashes, do not pull out the CF card, preventing the file system damage on the hardware or CF card. � When installing the CF card, pay attention to the inserting direction of the CF card. copyright©2015 Maipu All rights reserved.
  • Page 113 Fit the removed SFP module with the dust cap and put it in the anti-static bag or packing box. The diagram of installing the dust cap for the SFP module is as shown in the following figure: copyright©2015 Maipu All rights reserved.
  • Page 114 M O D U L E M O D U L E Step 6: Insert the fibers into the SFP ports in order. The diagram of connecting the SFP to the fiber is as shown in the following figure: copyright©2015 Maipu All rights reserved.
  • Page 115 Step 5: Use the hand to hold the two corners of the memory, locate according to the alignment gap of the memory, insert the memory according to the arrow direction into the card socket. The copyright©2015 Maipu All rights reserved.
  • Page 116 I N S T A L L A T I O N 6.1.7 6.1.7 Change Change Chassis Chassis Filter Filter 6.1.7 6.1.7 Change Change Chassis Chassis Air Air Filter Filter � When the device is running, you can take down the air filter, but should install copyright©2015 Maipu All rights reserved.
  • Page 117 The changing mode of the air filter of S6600 series routing switch is similar. The following takes SM6600-08-MF as an example. The other devices are similar and the manual will not describe any more. The steps for changing the air filter are as...
  • Page 118: Installation Preparations

    A I R A I R A I R A I R F I L T E R F I L T E R F I L T E R F I L T E R copyright©2015 Maipu All rights reserved.
  • Page 119 Wear the anti-static wrists and use the cross screwdriver to loosen the captive screws on the air filter. Step 3: Take down the air filter from the chassis. Step 4: Pull out the black dustproof cushion embedded in the air filter. copyright©2015 Maipu All rights reserved.
  • Page 120 Otherwise, the chassis temperature will be too high, seriously threatening the security and stable running of the device. Step 3: The replaced and cleaned fan module will serve as the standby fan module. copyright©2015 Maipu All rights reserved.
  • Page 121 � When using the cleaner to remove the dust, use the private cleaner of the dry, non-corrosive, non-conductive, and highly-volatile circuit board to remove the copyright©2015 Maipu All rights reserved.
  • Page 122 � For the large-power laser interface, use the cleaning tools and materials to clean. � For the small-power optical interface, if there are no private cleaning tools or copyright©2015 Maipu All rights reserved.
  • Page 123 � Do not use the cleaning tools and materials that are not proved to be applicable to clean the optical interface and pigtail connector. copyright©2015 Maipu All rights reserved.
  • Page 125 B O A R D W E I G H T W E I G H T Model Weight (kg) Model Model Model Weight Weight Weight (kg) (kg) (kg) SM6600-04-MF frame (containing fan) SM6600-08-MF frame (containing fan) 38.5 AD1000-1S007Z DD1000-5S007Z SM66-MPUA SM66-MPUB SM66-SFUA SM66-SFUB copyright©2015 Maipu All rights reserved.
  • Page 126 C A R D S C A R D S Model Model Power Power consumption consumption Model Model Power Power consumption consumption (W) SM66-MPUA SM66-MPUB SM66-SIU SM66-SFUA SM66-SFUB SM66-8XGEF2QXGE 54.1 SM66-24GET24GEF 46.4 SM66-48GET SM66-48GEF 56.6 SM66-48GETP 63.5 copyright©2015 Maipu All rights reserved.
  • Page 127 Description SM66-MPUA The device core management/control SM66-MPUB The device core management/control � SM66-MPUA is the half-width MPU card, used by SM6600-04-MF. � SM66-MPUB is the full-width MPU card, used by SM6600-08-MF. A2.1 A2.1 A2.1 A2.1 SM66-MPUA SM66-MPUA SM66-MPUA SM66-MPUA The diagram of SM66-MPUA card panel is as follows:...
  • Page 128 On: DC0 interface is negotiated as 100M DC0 ACT Single-color Off: DC0 interface is down green On: DC0 interface links. But has no data sent and received Flash: DC0 interface has data sent and received copyright©2015 Maipu All rights reserved.
  • Page 129 C A R D Name Name Name Name Indicator Indicator Indicator Indicator Color Color Color Color Status Status Status Status Description Description Description Description Single-color Flash: The MOU card works normally green Off/on: The MPU card works abnormally copyright©2015 Maipu All rights reserved.
  • Page 130 The SFU card has the switching network unit of S6600 series routing switch, realizing the switching function of the service data between the LPU cards. If inserting two cards, realize the 1+1 backup function. SFU has the following specifications: Specification Specification Specification Specification Description Description Description Description copyright©2015 Maipu All rights reserved.
  • Page 131 LPU 0~3 Single-color Off: The uplink data link of the LPU slot is down green On: The uplink data link of the LPU slot is up Flash: The uplink data link of the LPU slot has copyright©2015 Maipu All rights reserved.
  • Page 132 C A R D C A R D P A N E L P A N E L � The SM66-SFUB card is only used by SM6600-08-MF. � The indicators on the SM66-SFUB panel indicate the working status of each LPU card respectively.
  • Page 133 S M 6 6 - 8 X G E F 2 Q X G E S U B S U B S U B S U B C A R D C A R D C A R D C A R D copyright©2015 Maipu All rights reserved.
  • Page 134 I N T E R F A C E S I N T E R F A C E S Interface Interface Name Name Description Description Interface Interface Name Name Description Description 0~23 10Base-T/100Base-TX/1000Base-T RJ45 interface 24~47 1000Base-x SFP optical interface copyright©2015 Maipu All rights reserved.
  • Page 135 C A R D I N T E R F A C E S I N T E R F A C E S Interface Interface Interface Interface Name Name Name Name Description Description Description Description copyright©2015 Maipu All rights reserved.
  • Page 136 N T R O D U C T I O N T O S U B S U B C A R D C A R D I N T E R F A C E S I N T E R F A C E S copyright©2015 Maipu All rights reserved.
  • Page 137 D I A G R A M O F P A N E L P A N E L P A N E L P A N E L The description of SM66-48GETP sub card interfaces is as follows: copyright©2015 Maipu All rights reserved.
  • Page 138 SIU Card Card Card The SIU card is used by SM6600-08-MF. One is optional. With the LCD panel and button, the user can query the product work status and indicate the system working status via the LED light. The SIU card has the following specification:...
  • Page 139 Installation Preparations MyPower S6600 Series Routing Switch Installation Manual � The SIU card is only used by SM6600-08-MF and it is optional. The diagram of the SM66-SIU panel is as follows: A A A A A A A A 1 0 T T T T...
  • Page 140 P O W E R M O D U L E M O D U L E M O D U L E M O D U L E Item Item Item Item Data Data Data Data Rated input voltage range 100V ~240V AC 50/60Hz copyright©2015 Maipu All rights reserved.
  • Page 141 P O W E R M O D U L E M O D U L E Item Item Item Item Data Data Data Data Rated input voltage range -40V - -57V DC Max. input voltage range -36V - -72V DC copyright©2015 Maipu All rights reserved.
  • Page 142 A T T R I B U T E S Attribute Attribute Attribute Attribute Description Description Description Description Interface standard IEEE 802.3, IEEE802.3u, IEEE802.3ab Connector type RJ45 Work mode 10Mbps/100Mbps/1000Mbps Half-duplex/full-duplex/auto-negotiation Maximum transmission 100m distance copyright©2015 Maipu All rights reserved.
  • Page 143: Port Attributes

    A T T R I B U T E S Attribute Attribute Attribute Attribute Description Description Description Description Interface standard IEEE 802.3ab Connector type Work mode 1000Mbpsfull-duplex Supported SFP interface Support 1000Base-X Connection cable Single-mode fiber or multi-mode fiber copyright©2015 Maipu All rights reserved.
  • Page 144 I N T E R F A C E A T T R I B U T E S A T T R I B U T E S Attribute Attribute Attribute Attribute Description Description Description Description Interface standard CompactFlash Specification Version 4.1 Complaint Interface type copyright©2015 Maipu All rights reserved.
  • Page 145 Installation Preparations MyPower S6600 Series Routing Switch Installation Manual Attribute Attribute Description Description Attribute Attribute Description Description Work mode Support hot plugging Cable None copyright©2015 Maipu All rights reserved.
  • Page 147 C C C C Cable Cable Cable Cable � It is recommended to use the related modules of Maipu on the device. � The following information is only for your reference. For details, please contact Maipu market personnel or technical personnel.
  • Page 148: Port Cable

    F I G U R E F I G U R E H E D I A G R A M D I A G R A M D I A G R A M O F copyright©2015 Maipu All rights reserved.
  • Page 149 9/125μm single-mode fiber SFP-S2-L24P3 1310nm 20KM Support 9/125μm (E1) DDMI single-mode fiber SFP-S4-L24P3 1310nm 40KM ― 9/125μm single-mode fiber SFP-S4-L24P5 1550nm 40KM Support 9/125μm (V2) DDMI single-mode fiber SFP-S8-L24P5 1550nm 80KM ― 9/125μm single-mode fiber copyright©2015 Maipu All rights reserved.
  • Page 150 R E L A T I O N S H I P R E L A T I O N S H I P T A B L E T A B L E T A B L E T A B L E copyright©2015 Maipu All rights reserved.
  • Page 151 P A R A M E T E R P A R A M E T E R T A B L E T A B L E T A B L E T A B L E copyright©2015 Maipu All rights reserved.
  • Page 152 Black Core wire color Brown Connect to 0V Blue Connect to-48V Yellow and green Connect to PGND Cable length Core wire CSA Connector Inner 5.0mm–5.5mm parameter diameter Outer 8.0mm–10.0mm diameter Thickness 1.0mm Texture Red copper copyright©2015 Maipu All rights reserved.
  • Page 153 (such as drying and airing) before the device is powered on, so as to prevent the internal components of the device from short-circuit and being burned. copyright©2015 Maipu All rights reserved.
  • Page 154 For the weights of the switch components, refer to Appendix A Specifications for Whole Device and Common Modules. copyright©2015 Maipu All rights reserved.
  • Page 155: H Andling

    We should prevent the harmful gases, such as SO2, H2S, NO2, NH3 and Cl2, from entering the equipment room. The specific limited values are as shown in appendix table D-4: copyright©2015 Maipu All rights reserved.
  • Page 156 The user should provide the well grounding system for the device. The resistance between the switch chassis and the ground should be smaller than 1ohm. copyright©2015 Maipu All rights reserved.
  • Page 157 Power Power Supply Supply Suggestions Suggestions D2.2 D2.2 AC AC Power Power Supply Supply Suggestions Suggestions Suggestions for AC power supply: � If the AC directly provides power for the device, the power supply voltage copyright©2015 Maipu All rights reserved.
  • Page 158 Power Supply Supply Supply Supply Suggestions Suggestions Suggestions Suggestions Suggestions for DC power supply: � The decentralized power supply mode is recommended. Use multiple DC power supply systems and deploy power devices at multiple sites. copyright©2015 Maipu All rights reserved.
  • Page 159 Configure the number of rectifier modules in the redundancy mode. � Install the storage battery in two groups or multiple groups. The total capacity is determined by the time of the storage battery supplying power to the load independently. copyright©2015 Maipu All rights reserved.
  • Page 161 The grounding resistance of the integrated communication building should be no more than 1ohm; in the common communication site, it should be smaller than 5ohm (for the area with high soil resistivity, it can be raised to 10ohm). copyright©2015 Maipu All rights reserved.
  • Page 162 C O M M U N I C A T I O N C O M M U N I C A T I O N P O W E R P O W E R P O W E R P O W E R copyright©2015 Maipu All rights reserved.
  • Page 163 The protection ground wire should adopt the yellow and green plastic insulated copper wire. The neutral line of the AC power cable in the equipment room cannot be connected with the protection ground of the transmission and communication devices in the equipment room. copyright©2015 Maipu All rights reserved.
  • Page 164 � If the actual conditions cannot meet the indoor wiring, the outdoor cables should be laid and buried (introduced to the indoor from the underground). � If you cannot lay and bury all outdoor cables, the aerial cables should be copyright©2015 Maipu All rights reserved.
  • Page 165 If the optical port is not connected to the optical connector, please be sure to wear a protective cap. � If the optical port is not connected to the optical connector and the protective cap is opened, maybe some invisible rays emitted from the optical port, so copyright©2015 Maipu All rights reserved.
  • Page 166 Fiber itself does not belong to the conductor, and it does not sense or transduce the over-voltage, but the strengthen core of the fiber optic cable (the armored component installed to prevent the fiber from being affected by the environment event) can easily sense and transduce the lightning copyright©2015 Maipu All rights reserved.
  • Page 167 D E V I C E E Q U I P O T E N T I A L E Q U I P O T E N T I A L 1. Device ground terminal 2. Device equipotential connection line 3. Ground protection cable 4. Ground bar copyright©2015 Maipu All rights reserved.
  • Page 169 Do not put it outside the cabinet where are easy to be touched. � The power cable is wired from the rear end of the cabinet. Arrange the wiring from top or from bottom according to the equipment room condition (power distribution cabinet, and terminal strip). copyright©2015 Maipu All rights reserved.
  • Page 170 � Bind the cable using cable ties and cut the unnecessary parts. The cut should be smooth and neat, without sharp corner, as shown in the following figure. The diagram of binding the cable is shown as follows: copyright©2015 Maipu All rights reserved.
  • Page 171 � Use the cable fixed by thread to connect the terminal. The screw or nut should be fixedly fastened and loose preventing measures should be adopted, as shown in the following figure, copyright©2015 Maipu All rights reserved.
  • Page 172 � No cable wiring or binding should be crossed with each other. � For the wiring terminal socket of the crimping cold-pressure terminal type (such as air switch), the metal part of the cold-pressure terminal cannot be exposed to the external terminal socket when assembling. copyright©2015 Maipu All rights reserved.
  • Page 173 The environmental protection use period of the Li battery of the product is 5 years; the environmental protection use period of the other components is 50 copyright©2015 Maipu All rights reserved.
  • Page 174 For the use conditions of the product in the environmental protection use period, refer to the requirements for the use environment in the product manuals. � In the statement, list all components that may be configured in Maipu products. For the actual components contained in each product, please prevail in kind.