Summary of Contents for Maipu MyPower S2300-28TC-AC
Page 1
MyPower S2300-28TC-AC Switch Installation Manual Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People's Republic of China - 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http: // www.maipu.com Email: overseas@maipu.com...
Page 2
The information in this document is subject to change without notice. In no event shall Maipu be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however...
Page 3
MyPower S2300-28TC-AC Switch Installation Manual Preface Version Description This manual is applicable to the SM2300-28TC-AC L2 intelligent access switch. Manual Introduction This manual mainly describes how to install the SM2300-28TC-AC switch: Product Introduction: introduces the SM2300-28TC-AC switch, system feature ...
MyPower S2300-28TC-AC Switch Installation Manual Format Description An alert that contains additional or supplementary information. An alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software.
MyPower S2300-28TC-AC Switch Installation Manual Contents 1 Product Introduction ........................6 1.1 Overview ............................6 1.2 Physical Features ........................7 1.3 Product Appearance ........................8 1.3.1 Front Panel of SM2300-28TC-AC ..................8 1.3.2 Back Panel of SM2300-28TC-AC ..................8 1.3.3 LED Indicators .......................... 9 1.3.4 Port on Front Panel .......................
Maipu newly launched switch not only emphasize on the green, environmental, and energy-saving, but also has excellent performance and operability. This series switch adopts the new technologies such as RTCT, UDLD, Attack Prevention, and MAC address learning restriction.
MyPower S2300-28TC-AC Switch Installation Manual Link backup FlexLink and dynamic link aggregation LACP 2. Comprehensive network security 512 L2-L4 basic/extended/self-defined ACLs 802.1x and MAC user authentication, tetrad user binding DHCP snooping and IP Source Guard User-based dynamic ARP detection and protection 3.
MyPower S2300-28TC-AC Switch Installation Manual Item Description Input voltage AC: 90–264V, 47–67Hz Temperature -20℃ to 50℃ Related humidity 10-90% (non-condensing) Max power consumption < 24W Mean time between failures (MTBF) 80,000 hours 1.3 Product Appearance 1.3.1 Front Panel of SM2300-28TC-AC Front panel of SM2300-28TC-AC switch has 24*10/100/1000Base-T ports, 4*GE Combo ports, 1*Console port, and 30*LED indicators.
MyPower S2300-28TC-AC Switch Installation Manual 1.3.3 LED Indicators The indicators on the front panel of SM2300-28TC-AC have port indicators and system status indicators, with the same meanings of indicator status, as below: 1.3.3.1 Port Indicator 1 - 4 D S M 2 3 0 0 - 2 8 T C - A C...
Page 13
MyPower S2300-28TC-AC Switch Installation Manual Service Realization Provide 512 L2 multicast address tables. Support GMRP. Multicast Support IGMP-Snooping. The number of broadcast packets can be Broadcast storm suppression configured. Support IEEE 802.1d/1s/1w spanning tree protocol. Port aggregation Support 8 aggregation groups...
Page 14
MyPower S2300-28TC-AC Switch Installation Manual Service Realization Support Xmodem, FTP and TFTP protocol to Upgrading realize upgrading. Support MP.Link. Support network management system. Support command-line interface (CLI) configuration on the serial port. Management Support Telnet remote configuration. Supports SNMP management.
MyPower S2300-28TC-AC Switch Installation Manual Installation Preparations 2.1 Security Suggestions To avoid device damage and bodily injury caused by accident, please follow the following precautions: Keep the switch free from damp and heat. Ground the switch properly. Please wear the ESD wrist strap during the installation and ...
MyPower S2300-28TC-AC Switch Installation Manual Do not locate switch on unstable box or desk. Falling may cause severe damage to switch. Keep the ventilation of the room and the switch. Switch can work normally under proper power pressure. Please check ...
MyPower S2300-28TC-AC Switch Installation Manual 2 - 1 T A B L E H E T E M P E R A T U R E A N D H U M I D I T Y R E Q U I R E M E N T S I N E Q U I P M E N T R O O M...
MyPower S2300-28TC-AC Switch Installation Manual some metal parts. The detailed limit value for the harmful gas such as SO S, NH and CL in the equipment room is as follows: 2 - 3 T A B L E H E L I M I T V A L U E O F H A R M F U L G A S I N T H E E Q U I P M E N T R O O M Maximum (mg/m 0.006...
MyPower S2300-28TC-AC Switch Installation Manual 2.2.4 Electromagnetic Requirement This jamming sources, no matter from device or exterior application system, exert influences on devices through capacitance coupling, inductance coupling, electromagnetic wave radiation, common impedance (including grounding system) and conducting wire (power wire, cable and output wire). Pay attention to the...
MyPower S2300-28TC-AC Switch Installation Manual 2.3 Check Device and Accessories When the installation environment is confirmed to meet the requirement, then you can open the package. Before the installation begins, you need to carefully check whether the device and accessories in the package are complete according to the packing list.
ESD wrist strap, configuration terminal (such as a PC), power line, Console cable, and RJ-45 connector network cable. 3.1.2 Check Cabinet Maipu devices can be normally installed and fixed in the cabinet. Before the installation, reserve enough empty slot space for the device. 3 - 1 H...
Page 22
MyPower S2300-28TC-AC Switch Installation Manual Use a ruler or tape to measure the horizontal installation hole central distance and horizontal direction installation net space. The dimension is shown in Figure 3-1. Check whether the support board or tray, floating nut, fixed screw, and blank panel on the cabinet are complete.
MyPower S2300-28TC-AC Switch Installation Manual 3.1.2 Check Device and Accessories When the installation environment is confirmed to meet the requirement, open the device packing box and check whether the devices and accessories in the packing box is complete according to the device packing list.
Page 24
MyPower S2300-28TC-AC Switch Installation Manual collision. The heavier or higher device should be operated with two people. Step 4: Push in the device simultaneously and cling the cabinet tray to the cabinet upright. Step 5: Use the fixed screwdriver to install the device to the cabinet upright, as shown in Figure 3-4.
MyPower S2300-28TC-AC Switch Installation Manual 3.3 Device Cable Connection This chapter describes how to connect the cable of the SM2300-28TC-AC switch to the network, including connecting the console port of the switch. 3.3.1 Switch Console Port Connection The SM2300-28TC-AC switch provides one EIA/TIA-232 asynchronous serial console port.
Page 26
MyPower S2300-28TC-AC Switch Installation Manual (that is PGND ground), which must connect the ground well. This can enable the induced electricity and leakage electricity to safely flow into the earth and improve overall EMI feature. For the external network connection, such as the E1 interface, PSTN and other cable series with the lightning voltage, ground can provide protection.
MyPower S2300-28TC-AC Switch Installation Manual 4 Cable Description 4.1 Ethernet Electrical Interface Cable The Ethernet interface cable of the SM2300-28TC-AC switch is 8-core unshielded twisted pair. 1 and 2 are tx ports and 3 and 6 are rx ports. 4 - 1 R J 4 5...
MyPower S2300-28TC-AC Switch Installation Manual RJ45 Signal Direction RJ45 Description Length <— Twisted pair 2 <— —> Twisted pair 3 —> <— Twisted pair 4 <— 4.2 Ethernet Optical Interface Cable The Ethernet optical interface cable of the SM2300-28TC-AC switch is SM or MM fiber of the LC interface.
Page 29
MyPower S2300-28TC-AC Switch Installation Manual 4 - 1 D D B 9 I G U R E I A G R A M O F S T A N D A R D I N T E R F A C E...
MyPower S2300-28TC-AC Switch Installation Manual 5 Troubleshooting 5.1 Power System Failure SM2300-28TC-AC Fast Ethernet Switch can judge whether the switch power system is faulty according to the power indicator on the front panel. When the power system works normally, the power indicator keeps always on; if it is off, please conduct the following examinations: Check whether the power line of the switch is correctly connected.
MyPower S2300-28TC-AC Switch Installation Manual Check whether the Console cable is correctly connected. If no problem is found in above examination, may be the configuration cable is faulty or the terminal (such as hyperterminal) parameter setting is incorrect. In such case, conduct the corresponding check.