  • Page 1 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: overseas@maipu.com Maipu Confidential &...
  • Page 2 Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes.
  • Page 3 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Maipu Feedback Form Your opinion helps us improve the quality of our product documentation and offer better services. Please fax your comments and suggestions to (86) 28-85148948, 85148139 or email to overseas@maipu.com.
  • Page 4: Table Of Contents

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Contents Product Introduction...................5 Overview........................5 Product Features ........................6 Appearance......................7 Front Panel ..........................7 Back Panel..........................8 LEDs ............................8 Installation Notice ..................12 Installation Guide....................12 Environment..........................12 Installation Instructions ......................15 Security Warnings ........................15 Device Installation..................17 Installation Preparation..................17 Check Packing List........................17...
  • Page 5: Product Introduction

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Product Introduction Overview MyPower S4152F-POE-AC V2 diagram: MyPower S4152F-POE-AC V2 routing switch MyPower S4152F-POE-AC V2: 10/100/1000M auto-sensing Ethernet 1000M SFP CONSOLE Model port (RJ-45 port) port Port MyPower S4152F-POE- AC V2 One SFP port and the RJ-45 port form one Combo port, that is, only one of the two ports that form the Combo port can be used at one moment.
  • Page 6: Product Features

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Product Features Rich interface types MyPower S4152F-POE-AC V2 routing switch provides 44 fixed RJ-45 ports, four Combo ports (SFP/ RJ-45) and two 10G extended slots. Secure Power Supply MyPower S4152F-POE-AC V2 routing switch supports 220V AC input, 12V DC input or 220V AC/12V DC input simultaneously.
  • Page 7: Appearance

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 MyPower S4100 series switch fully supports DiffServ module. Each port provides eight priority queues. User specifies a queue bandwidth on each port. It supports WRR/SP/SWRR scheduling. Users deploy trusted CoS, DSCP, IP priority and port priority. Users modify packet values of DSCP and COS.
  • Page 8: Back Panel

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 The front panel of MyPower S4152F routing switch is as follows: Console port description MyPower S4152F-POE-AC V2 routing switch provides one RJ-45 serial console port. With the interface, the user can complete the local or remote configuration for the switch.
  • Page 9 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 No power or error The redundancy power unit accepts Green light energy. Redundancy power indicator The redundancy power unit is closed or error Flashing System auto diagnosis detection is green light...
  • Page 10: Power System

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Power System power range rated voltage range: 100V~240V; frequency Input requirement: 50/60Hz (+/-3Hz); DC power range: - ~-60V (rated -48V) POE module Max. power Supported Model DC input Protocol standard supported by...
  • Page 11 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 -40°C 70°C Storage temperature 10% 90%, no condensing Relative humidity MTBF Lowest 120, 000 hours MTBF Maipu Confidential & Proprietary Information Page 11 of 23...
  • Page 12: Installation Notice

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Installation Notice Installation Guide To ensure the security of you and others and the normal running of the switch when installing and using MyPower S4152F-POE-AC V2 routing switch, read the following instructions.
  • Page 13 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 (particles/m³) Environmental Requirements: Dust The switch will get damaged if the air comprises salt, acid and sulfide contents. Such harmful gases speed up metal corrosion and aging of some parts. The site should avoid harmful gases such as .
  • Page 14: Power Supply

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Power Supply The switch adopts modular power supply. Before switching on, ensure proper grounding of the power supply system. The input source for the switch should be reliable and secure. Use a voltage adaptor, if necessary.
  • Page 15: Installation Instructions

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Keep away from high power radio transmitters, radar transmitters, and high frequency strong circuit devices Provide electromagnetic shielding Rack Configuration The dimensions of the switch are designed to be mounted on a standard 19’’...
  • Page 16 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Do not install, remove, or disassemble switch and modules with power on to avoid injuring yourself or damaging the equipment. Do not open the switch without permission. Please resort to the manufacturer for help if any problem occurs, to prevent physical injuries and device damages.
  • Page 17: Device Installation

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Device Installation Installation Preparation Check Packing List Unpack and check the equipment inside as per the packing list. Tools & Utilities Required tools and utilities are as follows: Cross point screwdriver...
  • Page 18: Connect Console Cable

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Installing S4152F-POE-AC V2 on the rack Install the switch according to the following steps: Attach the brackets on both sides of the switch with screws provided in the accessory kit. Put the bracket-mounted switch onto a standard 19’’ rack. Fasten it at a proper location with the screws provided, leaving enough space around the switch for good air circulation.
  • Page 19: Install Sfp Transceiver

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Find the console cable provided in the accessory kit. Attach one connector of the cable to switch console port. Connect the other side of the console cable to a character terminal (PC).
  • Page 20: Connect Cable/Fiber

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Push the XFP transceiver until connecting the 10G module closely. XFP 10G fiber transceiver is hot-swappable. % Caution Do not look directly at the two-fiber bore in XFP 10G fiber transceiver when the switch is in operation.
  • Page 21: Connect Power Supply

    MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Caution: Verify sign on the interface to ensure using other ports. Connecting to wrong ports may damage the transceiver or other ports. When connecting other devices via a fiber to the switch, the output power of the fiber cable cannot exceed the maximum received power of the modules.
  • Page 22 The input voltage should be within the required range, or switch can be damaged or cannot work normally. If the power indicator is not blinking even after power on or self-check is abnormal, contact the dealer or Maipu Customer Service Center. Do not open the switch shell without permission.
  • Page 23 MyPower S4100 Series Switch Install Manual (S4152F-POE-AC V2) V1.0 Step 4: Insert the AC input cable to the AC input socket at the power back panel; Step 5: After confirming that all cables are connected well, close the AC input switch at the back panel and open the external POE power PCR01- 48/20 V3;...