This manual first describes the appearance, hardware structure, and board cards of MyPower S12800 router; secondly, describes the installation preparations of the device and how to install it to the cabinet; at last, describes the basic using methods and daily maintenance of the device from the aspects of powering on and running the router, troubleshooting and device maintenance.
Page 3
Obtaining Documentation You can access the most up-to-date Maipu product documentation on the World Wide Web at www.maipu.cn. Maipu Confidential & Proprietary Information Page 3...
Page 4
S12800 Routing Switch Installa tion Manual V1.0 Technical Support Technical supporting hotline: 400-886-8669 Fax: (+8628)85148948 Documentation Feedback You can feed back your opinions and suggestions by: Email: techsupport@maipu.com Technical hotline: 400-886-8669 We appreciate your comments. Revision Records...
1.1 Device Appearance and Hardware MyPower S12800 series routing switch contains one product model: SM12800-12-MF (V1). S12800 routing switch contains four slot types, that is, MPU, SFU, LPU, and SAIC. The four slots should be inserted with MPU card, SFU card, LPU card, and SAIC card respectively.
Page 10
S12800 Routing Switch Installa tion Manual V1.0 SM12800-12-MF (V1) is as shown in Figure 1-1 and the back appearance diagram is as shown in Figure 1-2. Figure 1-1 The front appearance diagram of SM12800-12-MF (V1) 1.Head 2. System indicator 3. Slot 0 0 of LPU card 4.
MPU: Main Processing Unit control card The MPU card is the most important and mandatory card in S12800 routing switch. It serves as the control center of the device. Each shelf can support two MPU cards at the same time, realizing the 1:1 backup work mode.
SFU: Switching Fabric Unit switch card The SFU card is the switch network unit of S12800 routing switch, bearing the switching function of the service data between the LPU cards. S12800 supports four SFU cards at most, realizing the 1+n backup function.
S12800 Routing Switch Installa tion Manual V1.0 1.4 Introduction to LPU card LPU: Line Processing Unit subscriber line interface card. It provides various interface shapes for the user to select, meeting various application scenario requirements. The appearance diagram of the LPU card is as follows: Figure 1-5 The appearance diagram of the LPU card 1.
5. Power elastic snap 1.7 Fan Module and Device Air Passage The fan module of S12800 routing switch is the important part of ensuring the normal running of the device system (mandatory module), providing the air flow for the system dissipation. It...
5. Fan handle 1.7.2 Device Air Passage The inlet and outlet air passages of S12800 routing switch chassis: The air flow comes in from the front and goes out from the back. The diagram is as follows: Maipu Confidential & Proprietary Information...
Page 16
S12800 Routing Switch Installa tion Manual V1.0 Figure 1-9 The air passage diagram of S12800 routing switch chassis Keep the device air passage unblocked during operation. The noise 25℃ environment of the whole device ≤75dBA. Maipu Confidential & Proprietary Information...
When the device is delivered, there is the packing list. Please confirm whether the accessories are complete and good according to the items in the packing list. If there is damaged or loss, please contact Maipu technical staff to replace. 2.1 Check Device Running Environment 2.1.1 Check Equipment Room Conditions...
Manual V1.0 2.1.2 Check Power Supply System The good power supply system is the basis of the device power-on starting and stable running. To meet the power supply requirement of S12800 routing switch, please complete the following steps: Step 1: Estimate the whole power consumption of the device.
S12800 Routing Switch Installa tion Manual V1.0 2.2.2 Electrical Safety Please check whether there are potential dangers. For example, the power is not grounded, power supply grounding is not reliable, and the ground is wet. Before installation, get to know the location of the emergency power switch in the room;...
Figure 2-1 Using method diagram of anti-static wrist 2.2.4 Handling Safety S12800 routing switch is large and heavy. When moving it, please pay attention to the following requirements: Before handling or moving the device, unplug all external cables (including power cable).
2.4 Wooden Box Open-package The shelf of S12800 routing switch adopts the wooden packaging. The packaging of one shelf comprises the wooden box, plastic bags, protection EPE and other packaging materials. Before opening the box, move the packing box to the equipment room or near to the equipment room (if the space permits), so as to avoid damaging the shelf when moving.
Page 22
S12800 Routing Switch Installa tion Manual V1.0 The opener is at one top corner of the wooden box top surface. Find the opener and removes it. Figure 2-2 The diagram of removing the opener Step 4: Open the alligator clips at the sides of the wooden box.
Page 23
S12800 Routing Switch Installa tion Manual V1.0 Figure 2-4 The effect drawing after opening the box After opening the box, confirm whether the accessories are complete according to the packing list. Keep the accessories in the box for installation.
3.4 Check after Installation 3.1 Install Device to Cabinet This section describes how to install the S12800 routing switch to the 19-inch standard cabinet. 3.1.1 Installation Preparations The user customized cabinet should be 19-inch standard cabinet, and the cabinet depth ...
S12800 Routing Switch Installa tion Manual V1.0 3.1.2 Adjust Cabinet To ensure that the device can be installed to the cabinet normally, it is required that the depth of the cabinet front pillar and square hole column is larger than 120mm and the width of the square hole column at the two sides of the cabinet is 450mm.
Page 26
Before installing the pallet, confirm whether the load-bearing capability of the used pallet meets the weight requirement of S12800 chassis and inside inserted cards. For the weights of the components, refer to Appendix A Entire Device and Common Module...
S12800 Routing Switch Installa tion Manual V1.0 For the dimension of SM12800-12-MF (V1), refer to 1.1 Device Appearance and Hardware Step 2: Maintain the level of the tray, the tray is installed to the marked position, and lock the fixing screw.
S12800 Routing Switch Installa tion Manual V1.0 Step 2: Install the floating nuts at the marked position (Each installation hole on the mounting ear should be installed with one floating nut), as shown in Figure 3-5. Figure 3-5 Install the floating nut 1.
Page 29
S12800 Routing Switch Installa tion Manual V1.0 Step 2: Lift the host and place on the bearing pallet and push the chassis into the cabinet until the mounting ears at the two sides of the chassis fit the square hole post, as shown in Figure 3-7.
S12800 Routing Switch Installa tion Manual V1.0 Figure 3-8 Fix the chassis The mounting ears do not bear the weight. Do not bear the device only using the mounting ears without installing the pallet. 3.1.6 Install Cabling Rack The cabling rack includes two kinds: one has three slots and the other has two slots. Each kind is also divided to L-direction and R-direction.
Page 31
S12800 Routing Switch Installa tion Manual V1.0 Figure 3-9 The diagram of the cabling rack 1. Cabling rack direction mark 2. Slot mark 3. Installation hole When installing the cabling rack, insert the two installation holes on the cabling rack to the stub on the mounting ears of the chassis, and then use the configured screws to lock, as shown in Figure 3-10.
S12800 Routing Switch Installa tion Manual V1.0 Figure 3-11 The order diagram for installing the cabling rack 3.1.7 Install Power Module Install in order according to the number of the purchased power modules. The power is packed in the separate packing box, but not in the chassis packaging...
S12800 Routing Switch Installa tion Manual V1.0 Step 3: Push the power module until the snap locks with the chassis. 3.1.8 Arrange Cables After the service modules on the slots are connected with the cables, the cables go out from the corresponding cabling rack of the slot, as shown in Figure 3-13.
S12800 Routing Switch Installa tion Manual V1.0 3.1.9 Install Nose and Power Dust-proof Net Take out the nose from the packing box, aim the nose at the pins at the upper part of the host shelf, and push it until being buckled. The diagram of installing the nose is shown in Figure 3-...
S12800 Routing Switch Installa tion Manual V1.0 3.2 Device Grounding For the device and human security, the device must be grounded well. The resistance between the device chassis and the ground should be less than1 ohm. Generally, there is the grounding bar on the cabinet and we can connect the ground cable of the device to the grounding bar.
S12800 Routing Switch Installa tion Manual V1.0 If there is no appropriate grounding point on the cabinet, we also can connect the grounding cable of the router to other grounding bar of the installation place. Fire hose and lightning rod grounding of the building are not the proper grounding location;...
S12800 Routing Switch Installa tion Manual V1.0 When using the power SPD, ensure the PE terminal is grounded. Insert the AC power plug of the router into the socket of the power SPD (surge protection connector bar). When only the green indicator indicating the running power SPD is always on without red indicator alarms, the SPD function works.
S12800 Routing Switch Installa tion Manual V1.0 Avoid the installation direction of the port lightning protector is connected reversely. The external cable is connected to the IN end and the device network port is connected to the OUT end.
4.1.1 Connect Configuration Cable S12800 routing switch provides two serial ports (EIA/TIA-232) and (Micro USB 2.0). With the two interfaces, the user can adopt the PC (or laptop) with the RS-232 serial port (or USB interface) to configure the switch.
Page 40
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-1 Connect the switch and PC via RS-232 serial port Figure 4-2 Connect the switch and PC via USB serial port The configuration cable used by RS-232 serial port (delivered with the device) is one eight- ...
S12800 Routing Switch Installa tion Manual V1.0 4.1.2 Set PC HyperTerminal Parameters The following takes running Windows XP HyperTerminal on the PC (or laptop) as an example to describe the setting of the serial interface parameters of the PC (or laptop).
Page 42
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-5 HyperTerminal connection description interface Step 4: Display the following Connect to interface, select the serial interface used by the connection in the Connect using, and click OK. Figure 4-6 The setting of the serial interface used by connecting HyperTerminal...
Page 43
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-7 Serial interface parameter setting Step 6: Display the following test-HyperTerminal interface, and click Properties. Figure 4-8 “test-HyperTerminal” interface Step 7: Display the following “test properties” interface, click Setting, select VT100 in Terminal emulation, and click OK.
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-9 “Test properties” interface Step 8: Display the following test-HyperTerminal interface, press Enter at the blank place, and the serial port displays the print information. The setting of the HyperTerminal is complete.
Page 45
Control the power-on via the switch of the power strip. S12800 power module has no power switch. When inserting the power module to the shelf for the first time, and the connecting the power supply cable, the device automatically powers on.
After the switch is powered on and starts, the configuration terminal will display some basic manufacturing information of the switch, such as: MyPower (R) Operating System Software MyPower S12800 system image file (yflash0: /yflash/sp9b-g-8.1.0(1)-dbg.pck), version 8.1.0(1), Compiled on Aug 28 2015, 03:57:29 Copyright (C) 2015 Maipu Communication Technology Co.,Ltd.All Rights Reserved.
S12800 Routing Switch Installa tion Manual V1.0 Connection steps: Step 1: Insert one side of the Ethernet twisted pair to the Ethernet electrical interface of the switch (RJ-45 port). Step 2: Insert the other side of the Ethernet twisted pair to the RJ-45 port of the device connected to the network.
Page 48
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-14 Pull out the dust plug Figure 4-15 SFP module Figure 4-16 Install the SFP module Before installing the fiber, do not pull out the dust plug on the SFP module. ...
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-17 Remove the dust cap of the fiber Remove the dust plug of the SFP module, as shown in Figure 4-18. Step 3: Figure 4-18 Remove the dust plug of the SFP module...
Page 50
S12800 Routing Switch Installa tion Manual V1.0 the fiber connector to the optical module. The appearance of the general MPO fiber connector is as shown in the following figure: Figure 4-20 MPO fiber connector I n s t a l l O p t i c a l M o d u l e The installation steps of the MPO QSFP+ module are as follows: ...
Page 51
S12800 Routing Switch Installa tion Manual V1.0 Figure 4-22 Install the QSFP+ module Before installing the fiber, do not pull out the dust plug on the QSFP+ module. It is recommended not to insert the QSFP+ module with the fiber into the interface slot ...
This section describes various hardware management functions of the S12800 routing switch. With the function interfaces, the user can conveniently view the software and hardware version information of the S12800 routing switch, as well as the work status information of the hardware modules.
For example: switch#show version MyPower (R) Operating System Software MyPower S12800 system image file (dc0: sp9b-g-8.1.0.6(R).pck), version 8.1.0.6(R), Compiled on Sep 18 2015, 07:55:53 Copyright (C) 2015 Maipu Communication Technology Co.,Ltd.All Rights Reserved. MyPower S12800 Version Information...
You can use the show system fan command to view the information of the fan module used on S12800, including the fan location information, fan speed, fan work status, fan module serial number, fan rotating speed, plugging times of the fan module, error plugging times, and other information.
You can use the show system power command to view the information of the power module used on S12800, including the online information of the power module, work status of the power module, swapping times of the power module and the error swapping times. For...
Page 56
S12800 Routing Switch Installa tion Manual V1.0 System Power Information(Power 1 - ONLINE) ---------------------------------------------------------------- Status: Normal Last-Alarm: Normal Description: N/A ---------------------------------------------------------------- STATISTICS: 1 IN, 0 OUT, 0 IERR, 0 OERR System Power Information(Power 2 - ONLINE) ---------------------------------------------------------------- Status: Normal Last-Alarm: Normal...
4.3.5 View Backplane Status Information You can use the show system chassis command to view the information of the backplane used on S12800, including the backplane online information, shelf type, backplane serial number, the MAC address stored on the backplane storage chip. For example:...
You can use the show system mpu command to view the information of the MPU card on S12800, including card online information, card name, card status information, the hardware and software version information of the card, the card storage space status information, and so on.
Page 60
S12800 Routing Switch Installa tion Manual V1.0 Field Description Card-SubSlot-Num The number of the MPU card sub slots: MPU card does not have sub slot, so it is 0 by default. Power-INTF-Status MPU card power status, such as Normal Power-Card-Status...
Page 61
S12800 Routing Switch Installa tion Manual V1.0 Field Description Core-State CPU core status information Core-Idx-00 CPU core serial number, such as Core-Idx-00 Core-Status CPU core status, such as 0000 Core-Utilization CPU core utilization, such as 0% Temperature CPU temperature Temperature-State...
You can use the show system sfu <slot number> command to view the information of the SFU card on S12800, including card online information, card name, card status information, the hardware and software version information of the card, the card storage space status information, and so on.
Page 64
S12800 Routing Switch Installa tion Manual V1.0 Field Description Serial No SFU card serial number Card-Name SFU card name, such as SM128-SFUB(V1) Description The description information field, configured by the user Power-RT-Infomation SFU card power real-time information Voltage-In The internal voltage of the SFU card, such as 3.38...
Page 65
S12800 Routing Switch Installa tion Manual V1.0 Field Description Core-Utilization CPU core utilization, such as 0% Temperature CPU temperature Temperature-State CPU temperature status Temperature = CPU temperature, such as 35℃ Last-Alarm = CPU temperature alarm, such as: Normal: CPU temperature has no alarm...
You can use the show system lpu <slot number> command to view the information of the LPU card on S12800, including card online information, card name, card status information, the hardware and software version information of the card, the card storage space status information, and so on.
Page 67
S12800 Routing Switch Installa tion Manual V1.0 Field Description System Card Information LPU card status, such as Lpu 2 - ONLINE Type LPU card type, such as: SM128-16QXGE-DA(V1) [0x8586200a] Status LPU card status, such as Start ok Start ok: LPU card is started successfully ...
Page 68
S12800 Routing Switch Installa tion Manual V1.0 Field Description Temperature-Information The temperature information of the LPU card Temperature-State LPU card temperature status Temperature = LPU card PCB temperature, such as 65℃ Last-Alarm = The PCB temperature alarm information of the LPU...
OERR: The physical error pull-out times, such as 0 4.3.9 View Swappable Optical Module Information You can use the show optical all command to view the work parameters of all optical modules used on S12800 routing switch. switch#show optical all Name...
Page 70
Besides, you can use the following commands to view the details of the inserted optical module on one specified port of S12800, including the optical module name, interface type, supplier name, optical module model, optical module serial number, the production date of the optical module, the sending power of the optical module and so on.
Page 71
S12800 Routing Switch Installa tion Manual V1.0 Field Description Transmit Distance The transmission distance of the optical module, such as 5m cable Vendor OUI The supplier ID Vendor Name The supplier name Part Number The optical module model Revision Number...
S12800 Routing Switch Installa tion Manual V1.0 5 Troubleshooting This chapter describes how to exclude the installation failure of S12800, including: 5.1 Troubleshooting of Configuration System 5.2 Troubleshooting about Power Fault 5.3 Fan Troubleshooting 5.4 Troubleshooting of MPU Card 5.5 Troubleshooting of SFU Card 5.6 Troubleshooting of LPU Card...
Parameters. 5.2 Troubleshooting about Power Fault The module power of S12800 routing switch is AD1600-1D005M AC module power. There is one status indicator on the panel of the module power, used to indicate the work status of one power module. The definition is as follows:...
5.3 Fan Troubleshooting The configured fan module of S12800 is FAN-19A-01. FAN-19A-01 fan module is the mandatory module of SM12800-12-MF (V1) and supports hot-swap. SM12800-12-MF (V1) has four fan modules and should be installed with four FAN-19A-01 modules so that the system can run normally.
5.4 Troubleshooting of MPU Card S12800 routing switch supports two MPU card (control card) slots. If two MPU cards are inserted, one is active and the other is standby. In the normal working state, the SYS indicator on the MPU card panel is in the flashing state.
S12800 Routing Switch Installa tion Manual V1.0 If the fault still cannot be located by the preceding steps, please contact the agent or local technical service engineers. 5.6 Troubleshooting of LPU Card On the panel of each LPU card, there is one STA dual-color status indicator. In the normal state, STA flashes (it indicates that the card is loaded successfully and in the normal working state).
Page 77
S12800 Routing Switch Installa tion Manual V1.0 Maintenance agreement or warranty card Simple description of the fault problem Simple introduction of the taken troubleshooting steps You can contact the customer service via the customer service hotline and you can also search for help via the website or email.
C h a n g i n g S t e p s The chassis of S12800 routing switch only supports the AC power module. The steps of changing the AC power module are as follows: Step 1: Wear an antistatic wrist strap, and make sure anti-static wrist strap is well grounded.
Page 79
S12800 Routing Switch Installa tion Manual V1.0 Step 2: Remove the power dustproof cap according to the arrow direction in the following figure: Figure 6-1 Remove the power dust proof cap Step 3: Pull out the power cable plug according to the following figure. If the bundle is tight, you can first loosen the bundle.
Figure 6-6 Install the dustproof cap of the power module 6.1.2 Change MPU/LPU Card The MPU card and LPU card of S12800 routing switch both support hot-swapping. The following takes changing the MPU card as an example. Changing the LPU card is similar and will be not described any more.
Page 81
S12800 Routing Switch Installa tion Manual V1.0 P r e p a r a t i o n s b e f o r e C h a n g i n g Step 1: Wear an antistatic wrist, and make sure anti-static wrist is well grounded.
Page 82
S12800 Routing Switch Installa tion Manual V1.0 Step 3: Slide along the guide rail smoothly to pull out the card. Place the un-installed card on the anti-static mat or the initial packing box. Figure 6-10 Insert the MPU card Step 4: Rotate outward the pullers at the two sides of the card to be installed and keep opened.
Manual V1.0 6.1.3 Change SFU Card In S12800, SM12800-12-MF (V1) supports four SFU cards. All SFU cards support hot-swap. The following takes changing the SFU card as an example to describe. P r e p a r a t i o n s b e f o r e C h a n g i n g Step 1: Wear an antistatic wrist, and make sure anti-static wrist is well grounded.
Page 84
S12800 Routing Switch Installa tion Manual V1.0 Step 3: Use two hands to hold the pullers on the card, and turn out the puller to make the card break away from the chassis backplane. Figure 6-15 Open the card puller Step 4: Slide along the guide rail smoothly to pull out the card.
(it is suggested that the whole changing process does not exceed 2minutes) to ensure normal switch working. The fan module changing process of S12800 routing switch chassis is similar. The following takes SM12800-12-MF (V1) as an example to describe how to change the fan module. The...
S12800 Routing Switch Installa tion Manual V1.0 Figure 6-18 Un-install the fan module Step 3: Push the fan module to be installed along the guide rail stably into the fan module slot to enable the fan module to closely contact the chassis backplane.
Page 87
S12800 Routing Switch Installa tion Manual V1.0 Figure 6-20 The diagram of the SD card slot 1.SD card slot 2. SD card status indicator The SD card is optional and supports hot-swap, installed on the MPU card of the switch. When the capacity of the SD card is insufficient or damaged, it is necessary to change.
S12800 Routing Switch Installa tion Manual V1.0 6.1.6 Change Swappable Optical Module The changing processes of the SFP module, SFP+ module, and QSFP+ module are similar. The following takes the SFP module as an example to describe. When installing or uninstalling the SFP module, do not use the hands to touch the gold- ...
Page 89
S12800 Routing Switch Installa tion Manual V1.0 Figure 6-24 Install the dust cap of the SFP module Step 4: Up-turn the handle of the installed SFP module to the vertical position to lock the buckle at the top of the module. Use the hands to hold the two sides of the...
It is suggested not to insert the SFP module with the fiber into the slot directly. Please first pull out the fiber and then install. 6.2 De-dust the Device This section describes how to de-dust S12800 routing switch. 6.2.1 De-dust Fan Module 6.2.2 De-dust Card 6.2.3 De-dust Optical Interface and Pigtail Connector...
S12800 Routing Switch Installa tion Manual V1.0 Step 1: De-dust the standby fan module as follows. After the maintenance personnel correctly wear the anti-static wrist or gloves, use cleaning tools, such as a clean cotton cloth, anti-static brush, and cleaner, to dedust the fan blade and control circuit board.
S12800 Routing Switch Installa tion Manual V1.0 at the same time. De-dusting using a vacuum cleaner is easy to operate and of low cost conserving. But this method cannot de-dust thoroughly and cannot effectively remove the noxious gas attached on the surface of the card.
Page 93
S12800 Routing Switch Installa tion Manual V1.0 The laser on sent by the laser maser on the optical interface is invisible infrared light. When the laser directly radiates the human eyes, it may cause permanent injury for the human eyes.
S12800 Routing Switch Installa tion Manual V1.0 Appendix A. Entire Device and Common Module Specifications Power Consumption/Dimension/Weight Appendix table A-1 Power consumption/dimension Model Power Consumption Dimension SM12800-12-MF (V1) Single power 1600W 442mm×645mm×840.5mm (W×D×H) (When the device is fully loaded with the cards, it is suggested to...
SM128-SAIC MPU Card Specifications The MPU card is the most important and mandatory card in S12800 routing switch. It serves as the control center of the device. Each shelf can support two MPU cards at the same time, realizing the 1:1 backup work mode.
Page 96
S12800 Routing Switch Installa tion Manual V1.0 SM128-MPUB is the full-width MPU card, used by SM12800-12-MF (V1). A . 2 . 1 S M 1 2 8 - M P U B The diagram of SM128-MPUB card panel: Appendix figure A-1 The diagram of SM128-MPUB card panel...
Page 97
MPU card to set up the stacking system, the GE1/2 port is used to set up the stacking management link. The current software version only supports the LPU card to set up the stacking system. For details, consult Maipu technical supporting personnel.
Flashing: The stacking GE port is linked, and has data receiving and sending SFU Card Specifications The SFU card is the switch network unit of S12800 routing switch, bearing the switching function of the service data between the LPU cards. The specifications of the SFU card:...
S12800 Routing Switch Installa tion Manual V1.0 SM128-SFUB card is only used by SM12800-12-MF (V1). The meaning of the indicators on SM128-SFUB card is shown in the following table: Appendix table A-6 The meaning of the indicators on SM128-SFUB card...
Page 100
S12800 Routing Switch Installa tion Manual V1.0 Specification Overview SM128-44GET4GE-SA 44port gigabit electrical port + 4-port gigabit combo interface card A . 4 . 1 S M 1 2 8 - 5 2 X G E F - D A SM128-52XGEF-DA interface card is 10G Ethernet optical signal interface card and supports 52 10GBase-SR/LR/ER SFP+ optical interfaces.
Page 101
S12800 Routing Switch Installa tion Manual V1.0 Name Indicator Color Status description receiving The port indicators include ▲ and ▼ forms. ▲ indicates the status of the upper 2, 4, 6……and other even ports. ▼ indicates the status of the lower 1, 3, 5……and other odd ports.
Page 102
S12800 Routing Switch Installa tion Manual V1.0 Name Indicator Color Status description service and cannot recover automatically. The card is not powered on, or the card is powered on, but is not loaded normally Off: 40G port is not linked...
Page 103
S12800 Routing Switch Installa tion Manual V1.0 Interface Name Description XGE: 49~52 10GBase-SR/LR/ER SFP+ optical interface The meaning of the indicators on SM128-48GET4XGEF-DA interface daughter card is shown in the following table: Appendix table A-12 The meaning of the indicators on SM128-48GET4XGEF-DA interface...
Page 104
S12800 Routing Switch Installa tion Manual V1.0 A . 4 . 4 S M 1 2 8 - 1 6 X G E F 4 Q X G E - S A SM128-16XGEF4QXGE-SA interface card is the interface card formed by 10G Ethernet optical signal and 40G Ethernet optical signal.
Page 105
S12800 Routing Switch Installa tion Manual V1.0 Name Indicator Color Status description (QSFP+ own LED) sending and receiving Flashing: 40G port is linked and has data sending and receiving. When the 40G port works in the 4x10G mode: Off: 10G port is not linked...
Page 106
S12800 Routing Switch Installa tion Manual V1.0 Appendix table A-16 The meaning of the indicators on SM128-48GEF2XGEF-SA interface daughter card Name Indicator Color Status description Slow-flashing: The card is in the normal running state. 0.5Hz Green Fast-flashing: The card is in the IOS loading state, Fast-flashing: The monitor is starting.
Page 107
S12800 Routing Switch Installa tion Manual V1.0 The description of the interfaces on SM128-44GET4GE-SA interface daughter card is shown in the following table: Appendix table A-17 Introduction the interfaces on SM128-44GET4GE-SA interface daughter card Interface Name Description RJ45: 1~48 10Base-T/100Base-TX/1000Base-T RJ45 interface...
S12800 Routing Switch Installa tion Manual V1.0 ports. SAIC Card Specifications The SAIC card is used by SM12800-12-MF (V1) and one is mandatory, indicating the system working status via the LED. The specification of the SAIC card: Specification Overview SM128-SAIC System alarm card A .
The device is powered on. green green/slow-flashing 0.2Hz: The device is in the standby state. Power Module Specification S12800 route switch supports the AC power supply mode. The power module has the following specification: Specification Overview Maipu Confidential & Proprietary Information...
Page 110
S12800 Routing Switch Installa tion Manual V1.0 Specification Overview AD1600-1D005M AC power module, 1600W When the power module is inserted on the shelf, but does not provide the AC power input, the system regards that the power module is faulty and the system alarms.
S12800 Routing Switch Installa tion Manual V1.0 Project Data Max. input voltage range 90V -264V AC 47~63Hz Output voltage 54V, 12V AC 220V: 8A Max. input current AC 110V: 11A Max. output power AC 220V: 1600W AC 110V: 1200W When using the 110V dual-fire wire input, the maximum output power of AD1600-1D005M ...
S12800 Routing Switch Installa tion Manual V1.0 The meaning of the indicators on the FAN-19A-01 card is shown in the following table: Appendix table A-22 The meaning of the indicators on the FAN-19A-01 card Name Indicator Color Status description Red and green...
Manual V1.0 USB Console Port Attribute S12800 provides one USB Console port complying with USB2.0 specifications. With the interface, the user can complete the local configuration for the switch. For the attributes of Console port, refer to the appendix table A-2:...
S12800 Routing Switch Installa tion Manual V1.0 SM128-48GET4XGEF-DA card does not support the 100M half-duplex/full-duplex mode. 1000Base-X SFP Optical Port Attributes Appendix table B-4 1000Base-X SFP Optical Port Attributes Attribute Description Interface standard IEEE 802.3z Connector type Work mode...
Console Cable Connected to the nine-core serial interface socket of the PC, the console cable of S12800 is an eight-core unshielded cable. The one side of the cable is the crimping RJ-45 crystal plug and the other side is a DB9 (hole). The view of the console cable is shown in the following figure.
The adapter cable of USB Console port is the universal standard USB-Micro USB adapter cable. Ethernet Electrical Port Cables It is recommended that the Ethernet interface cable of S12800 is eight-core un-shielded category-5 or above straight-through twisted pair. Appendix table C-2 Connection relation table of RJ45 cable (category-5 twisted pair)
Page 118
S12800 Routing Switch Installa tion Manual V1.0 Relationship of 1000Base-X SFP Gigabit Optical Module and Corresponding Interface Cable Appendix table C-3 The relationship of 1000Base-X SFP gigabit optical module model and the corresponding interface cable Optical Center User Interface Cable Max.
16A power cable specification. C.10 16mm² Grounding Wire The diagram for the standard 16mm²grounding wire of S12800 is shown in the following figure: Appendix figure C-3 The grounding wire diagram The specification information of the grounding wire is shown in the following table:...
Page 121
S12800 Routing Switch Installa tion Manual V1.0 grounding. We can use the current limiting resistor and connection line to connect with the grounding device. The resistance of the current limiting resistor is 1MΩ. D . 1 . 2 T e m p e r a t u r e R e q u i r e m e n t To ensure that the device can work normally, it is recommended to maintain certain temperature in the equipment room.
Page 122
S12800 Routing Switch Installa tion Manual V1.0 Measuring points of the working temperature and humidity of S12800 in the equipment room mean the values measured from the floor above 1.5 m and 0.4 m from the front of the rack when there are no protection boards.
Page 123
S12800 Routing Switch Installa tion Manual V1.0 Max. Diameter (μm) Max. density (tablets/m 1.4×10 7×10 2.4×10 1.3×10 If there is no visible dust on the desk within three days, it meets the cleanliness requirement. Apart from dust, the switch equipment room has the strict requirements for salts, acids, and sulfides contained in the air, because these harmful gases speed up the eroding of metals and the aging of some components.
S12800 Routing Switch Installa tion Manual V1.0 D . 1 . 8 G r o u n d i n g R e q u i r e m e n t The well grounding system is the basis for the switch to run stably and reliably, and the important guarantee for anti-lightning, anti-jamming, and anti-static of the switch.
S12800 Routing Switch Installa tion Manual V1.0 If the AC directly provides power for the device, the power supply voltage exceeds –10% to 5% of the rated voltage, or exceeds the permitted voltage range of the device. We should adopt the voltage regulator to meet the requirement.
Page 126
S12800 Routing Switch Installa tion Manual V1.0 E . 1 . 3 D e v i c e G r o u n d i n g S p e c i f i c a t i o n s...
S12800 Routing Switch Installa tion Manual V1.0 Description protection ground bar of the same equipment room. AC power port should be added with lightning protection circuit. E . 1 . 5 L a y i n g S p e c i f i c a t i o n s o f G r o u n d W i r e s...
Page 128
S12800 Routing Switch Installa tion Manual V1.0 The general requirements for the wiring of the indoor cables: The cable installation is required to be done by category, avoiding that the cables of different categories are bundled with each other.
Page 129
S12800 Routing Switch Installa tion Manual V1.0 optical connector and the fiber type conform to the used optical port type. Before connecting the fiber, first confirm that the optical power of the receiving end does not exceed the upper threshold of the receiving optical power of the optical module.
Recommended Wiring Recommended Wiring in Installation When S12800 routing switch is connected with the cables, go leftward or rightward as desired, that is, pass through the cabling rack at the two sides. The cabling mode is shown in the following figure: Maipu Confidential &...
Page 131
S12800 Routing Switch Installa tion Manual V1.0 Appendix figure F-1 The diagram of S12800 wiring The wiring principle is that the interface cables are separate from the power cables. With the reasonable wiring, you can un-install or install the switch fan module, power module and other components, improving the efficiency.
S12800 Routing Switch Installa tion Manual V1.0 Recommended Line Bundling The bundling of the power cables Appendix figure F-2 Cable bundling After being bundled in the cabinet, the cables should be straight and neat, and there is no ...
Page 133
S12800 Routing Switch Installa tion Manual V1.0 When the cables need to bend, bundle before the cables bend, but the cable tie cannot be bundled to the bent area, so as to avoid greater stress in the cable, leaving the cable core rupture, as shown in the following figure.
S12800 Routing Switch Installa tion Manual V1.0 Cable Bundle Diameter (mm) Bundling Distance (mm) 80~150 10~30 150~200 200~300 Any cabling or bundling cannot tangle. For the wiring terminal block of the crimp cold terminal (such as air switch), the metal part ...
Page 135
For the use conditions of the product in the environmental protection use period, refer to the requirements for the use environment in the product manuals. In the statement, list all components that may be configured in Maipu products. For the ...