EAPL EMS-10 V4.0 Instruction Manual

Power/ energy

Advertisement

Quick Links

EAPL
EMS-10 V4.0
Model
INSTRUCTION MANUAL
POWER/ ENERGY
www.eaplindia.com
DIMENSION
CONNECTIONS
Accessories:
EMS 10 unit with button flap in
place.
Panel
locking
Clamps
with
screws
(Qty: 2 nos each)
Instruction Manual
Page 3 of 3
FRONT VIEW
1.
Top Display
Window
2.
Bottom Display
Window
3.
Previous button
4.
Scroll/Hold button
5.
Next button
6.
Select button
7.
Advance button
REAR VIEW
1, 2, 3, 4 : R, Y, B, N
5 ,6
: No connection
A,B (RS 485Communication port)
7,8
:
9, 10
: S1, S2 (R Phase)
11,12
: S1, S2 (Y Phase)
13,14
: S1, S2 (B Phase)
: Auxilary Supply (
15,16
85- 270 VAC/ DC
FUNCTION
1.
Connect 3 phase 4 wire voltage and
current circuit as per the diagram
given in the connection diagram.
2.
Connect rated auxiliary supply at
terminals 15 and 16
3.
Moment voltage is applied on
auxiliary terminal, display starts
showing parameter one by one in auto
scaling mode.
Following are the parameters displayed.
PARAMETERS
R-PF
Y-PF
B-PF
T-PF (TOTAL-PF)
R-W (Active Power)
Y-W (Active Power)
B-W (Active Power)
T-W (Active Power- TOTAL)
R-VAr (Reactive Power)
Y-VAr (Reactive Power)
B-VAr (Reactive Power)
T-VAr (Reactive Power-TOTAL)
R-VA (Apparent Power)
Y-VA (Apparent Power)
B-VA (Apparent Power)
T-VA (Apparent Power-TOTAL)
Active Energy (KWh)
Reactive Energy Cap (KVArhC)
Reactive Energy Ind (KVArhI)
Apparent Energy (KVAh)
Load Hours (LH)
Old Active Energy (OKWh)
Old Reactive Energy Cap (OKVrhC)
Old Reactive Energy Ind (OKVrhI)
Old Apparent Energy (OKVAh)
Old Load hours (OL)
Device ID (Communication Status)
)
Parameters can be viewed in SCROLL/HOLD mode
using SCROLL/HOLD button.
Press NEXT/ PREVIOUS to view respective parameter
in Hold mode
Once there is a power failure, Energy, Load Hour and
Hold/ Scroll status will be saved.
Connect terminals 7,8 to the converter using
communication cables.(details of communication cable
wiring drawing is shown below).connect a resistor of
120 ohms at the end of daisy chain as shown in figure.
Provide unique Id for devices to identify individual
units
.
Communication status is displayed in Dev ID
parameter. 'T' for Transmit, 'R' for Receive & 'U' for
device id mismatch
Note: All terminal to be screwed tightly, else the reading
may not be accurate.
DATA COMMUNICATION CABLE:
Manufacturer name: BELDEN
22AWG (7x30) stranded tinned copper, dateline insulated,
twisted pairs. Overall standard tinned copper drain wire.
Overall 90% coverage tinned copper braid shield. Black UV
resistant PVC jacket.
DOC NO: OD RE YN 45001 0 Rev NO: 01 Dtd: 16/10/2013
Page 1 of 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the EMS-10 V4.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for EAPL EMS-10 V4.0

  • Page 1 EAPL FRONT VIEW FUNCTION EMS-10 V4.0 • Parameters can be viewed in SCROLL/HOLD mode Model Connect 3 phase 4 wire voltage and using SCROLL/HOLD button. current circuit as per the diagram given in the connection diagram. INSTRUCTION MANUAL • Press NEXT/ PREVIOUS to view respective parameter...
  • Page 2 BOTTOM COMMENTS/ BOTTOM COMMENTS/ AUTOSCALING PRESS DISPLAY DISPLAY RANGE/ DEFAULT PRESS DISPLAY DISPLAY RANGE/ DEFAULT X = KVAh SHOWS SHOWS VALUE SHOWS SHOWS VALUE Initially starts with .000 KVAh # Enter CT- 1. Enter Device ID If X is greater than 000.999 KVAh then next value will be 001.000 KVAh. SECONDARY VALUE 2.
  • Page 3 : +91-80-28567561/2 ,/42802345 Check for device ID and baud rate between input bus bars and unit match in software and in Unit. • Use EAPL make converter for RS485/232 Disable power save mode in Master. Email : info@eaplindiamail.com conversion. •...