4. Preparations for use
(1) Insert the Coupler plug (diameter R 1/4) to the compressed air supply (R joint).
(Refer to page 8 for details). (The coupler and joint are not provided.)
(2) An air filter, regulator and lubricator should be fitted in the air line between the
compressor and the tool, within 3m of the tool.
(3) Adjust the supply pressure and the drip volume of the lubricator oil.
-Compressed air pressure: 0.5~0.6MPa.
-Oil drip volume from the lubricator: 1~2 drops/ 10∼20 nuts fastened
【Note】Use a lubricate oil endorsed by a lubricator manufacturer.
【Note】When the length of air hose between lubricator and tool is over 3m, lubricate
to coupler plug after every 500pcs. fastening of POP Nuts.
*Refer to P.21 for detail to lubricate to coupler.
【Reference】
Frequency of lubrication depends on a supply of lubricates or operating conditions.
Table 4−1 is a reference data.
Table 4−1
Supply of lubricate oil
20cc
50cc
130cc
1,000cc
WARNING!
According to the actual operating temperature, use an air hose able to withstand
0.7MPa at the maximum pressure in ordinary operating. Also make sure the hose
material is suitable for the operating environment (e.g. oilproof wear and abrasion
resistance etc.).
*For details, refer to a hose manufacturer's catalog.
Frequency (reference data)
After every 12,500pcs. fastening
After every 25,000pcs. fastening
After every 65,000pcs. fastening
After every 500,000pcs. fastening