7 Recommendations of Lubricants (for all manufactures)

7.1.2 Application temperature from -50 to +100 C

Lubricating oil DIN 51 502 CLP-HC
i.e. fully synthetic high-performance industrial gear oil based on poly alpha olefins (PAOs):
Viscosity class:
Pour point:
Compatibility with conventional coatings and sealants

7.1.3 Application temperature from -60 to +100 C

Lubricating oil DIN 51 502 CLP-HC
i.e. fully synthetic high-performance industrial gear oil based on poly alpha olefins (PAOs):
Viscosity class:
Pour point:
Compatibility with conventional coatings and sealants

7.2 Spur Gears (actuator size AB8 - AB80)

Lubricating grease DIN 51826 - KPF -1/2 G-20
i.e. High-graphite, bitumen-free permanent lubricant with outstanding EP properties:
Work penetration 0.1mm:
Observe operating temperature range!

7.3 Output Drive Type A and Spindle Drive (Linear Actuators)

Lubricating grease DIN 51862- G 1 -G
i.e. Water-resistant complex grease on Al soap basis, highly resistant to acids and alkalines:
work penetration 0.1 mm
Dripping temperature:
NLGI grade:
Acid-free, not or only marginally reacting with water
Observe operating temperature range!

7.4 Precision Components

Lubricating grease (or spray) DIN 58396- S1
i.e. High-creeping, water-displacing, low-viscosity grease chemically neutral to copper and plastics:
Work penetration 0.1mm:
Dripping temperature:
Evaporation loss:
Water resistance:
Observe operating temperature range!

7.5 Basic Lubricant Service Interval

On actuator maintenance, the old grease must be removed completely and replaced by a new one.
The service interval for Schiebel actuators is 10 years from the date of delivery
by Fa. SCHIEBEL Antriebstechnik Gesellschaft m.b.H, A-1230 Vienna
The functionality and operating life of the lubricants is, however, dependent upon operational
conditions. It may be necessary to take reduction factors into account.
14
ISO VG 68
<-55 C
min ISO VG 32
<-60 C
between 265 and 340.
around 265
about 260 C
1
175 to 385
over 150 C
max. 1%
Evaluation grade DIN
51807-1-40
Operating instructions for actuators type AB