MAINTENANCE
Drive Shaft
1.
Loosen screws (B) and remove
center locating screw (C). Pull
gear box and shield from drive
shaft housing.
2.
Pull flexible cable from the drive
shaft housing, wipe clean and re-
coat with 15 ml (0.5 oz.) of
grease.
3.
Slide the flexible cable back in
the drive housing. DO NOT get
dirt on the flex cable.
4.
Install the gear housing and shield assembly. Align locating screw hole
with hole in drive shaft housing.
5.
Tighten screws securely.

Edger Blade Replacement

Level 1.
Parts required: Blade, new split pin.
Note: Replace blade when it is bent, damaged, or worn shorter than
152.4 mm (6 in.).
1.
Remove split pin (A).
2.
Align hole in inner blade
adapter (B) with notch in gear
housing, and insert locking tool
(G) to prevent PTO shaft (C)
from rotating.
3.
Remove L.H. blade nut (D) by
turning clockwise. Remove
outer blade adapter (E), and
blade (F).
34
B
B
A
© 06/2018 ECHO Inc.
PE-2620/S
G
B
X7502350201