Table 4-2. Basic Maintenance Schedule—MLT6SK (Kubota
Check oil level
Check coolant level
Check fuel level
Check tire pressure
Inspect wheel bearings
Inspect all electrical connections
Inspect radiator fins for debris; clean as required
Inspect light tower winch for correct operation
Inspect fan belt for tightness
Inspect radiator hoses and clamp bands
Replace fan belt
Replace fuel filter element
Replace air filter element
Replace engine oil and oil filter
Lubricate leveling jacks
Remove sediment in fuel tank
Clean air filter element
Purge air from fuel system
Drain residual water from fuel filter
*
Replace the air cleaner element yearly, or after six cleanings, whichever occurs first.
**
Generac Mobile Products, LLC recommends that oil change intervals on the MLT6SK equipped with the Kubota
engine be extended to 750 hours after initial break-in. The engine comes from the factory with a larger sump that
holds 5.5 qts (5.2 L) of engine oil. After the initial 50 hour break-in and oil change, the sump, coupled with the larger
oil filter, allows the engine to operate up to 750 hours between routine oil changes. Hot, humid, or dusty conditions
can shorten engine oil service life, regardless of suggested oil change intervals. Always follow the recommendations
of the OEM engine manual that was shipped with the unit for specific operating instructions. If further technical
assistance is required, contact Generac Mobile Products Technical Service at 1-800-926-9768.