IDEAL SUPER PLUS 200/S Installation And Servicing page 4

Hide thumbs Also See for SUPER PLUS 200/S:
Table of Contents

Advertisement

Boiler Model No.
No. of Modules
Heat Output
Heat Input
Gas Rate
(Note 1)
Flue Gas Volume
at 100
C, 8.5% CO
o
2
Required Water Flow Rate
(+/-10%)
Hydraulic Resistance
Min. Static Head (Note 2)
Max. Static Head
Electricity Supply
Max. Running Power
Min. Gas Supply
Pressure ( Note 3)
Boiler Height - overall
Boiler Width - overall
Boiler Depth - overall
Weight of casing
Weight of Each Module
Weight of Water Header
Weight of Gas Header
Water Content
(excluding header)
Weight of Dry Boiler
Weight of Wet Boiler
Flow and Return
Connection (Note 4)
Gas Connection
Flue Pipe Size
(nominal bore)
Flue Socket Size
(Note 5)
Burner Injector Size
Main Burner Pressure
Fan Motor
Gas Type
Notes:
1. Flue gas volumes and gas rates are calculated using a C.V. of
1031 Btu/ft
(at 15
C & 1013.25 mb)
3
o
2. For further information on head requirements see page 6.
3. The minimum gas supply pressure is with all modules firing.
4. Flange size: refer to BS.4504 Pt.1
4
GENERAL
200/S
2
kW
200
Btu/h x 10
682.4
3
kW
235
Btu/h x 10
802.9
3
m
/h
22.1
3
ft
/h
778.8
3
l/s
109
ft
/min
231
3
l/s
4.3
gal/min
56.8
mb (in.w.g)
98 (39)
m (ft)
1.6 (5)
m (ft)
60 (197)
60 (197)
Nominal 230 V, 50 Hz, Single Phase. Max start current 1.9 A per module
W
400
mb
14.6
in. w.g
5.8
mm
1800
in
71
mm
910
in
35.8
mm (in)
990 (39)
990 (39)
kg
134
lb
296
kg
69.2
lb
152.5
kg
16.3
lb
36
kg
3.5
lb
7.7
l
19.8
gal
4.4
kg
308.5
lb
681.2
kg
328.3
lb
724.9
mm
65
in
2.5
Rc (in. BSP)
40 (1.5)
mm
250
in
10
mm
288
in
11.3
mm
12.0
in
0.47
mbar (in.w.g)
2.7 (1.1)
2.7 (1.1)
Type BCP 1506E : 230 V, 50 Hz, Single Phase, 75W, '06' rating
300/3
400/4
300/3
Alternative Alternative
3
4
3
300
400
300
1023.6
1364.8
1023.6
353
471
353
1204.4
1607.0
1204.4
33.1
44.2
33.1
1168.0
1558.7
1168.0
164
218
164
397
463
347
6.5
8.6
6.5
85.2
113.6
85.2
98 (39)
98 (39)
98 (39)
1.6 (5)
1.6 (5)
1.6 (5)
60 (197)
60 (197)
600
800
600
14.8
15.1
14.8
5.8
6.1
5.9
1900
1900
1900
74.8
74.8
74.8
1510
1510
2115
59.5
59.5
83.25
990 (39)
990 (39)
144
144
208
318
318
459
69.2
69.2
69.2
152.5
152.5
152.5
38.2
38.2
49.8
84.2
84.2
109.8
9.4
9.4
12.6
20.7
20.7
27.7
29.7
39.6
29.7
6.5
8.7
6.5
437.4
506.6
437.4
964.3
1116.9
1964.3
466.9
546.1
466.9
1029.3
1203.9
1029.3
125
125
125
5
5
5
350
350
450
14
14
18
401
401
500
15.8
15.8
19.7
12.0
12.0
12.0
0.47
0.47
0.47
2.7 (1.1)
2.7 (1.1)
I
2H
5. Flues to BS.835 will fit directly onto the 300/3 Alternative,
400/4 Alternative, 500/5 and 600/6 boilers. For all boilers
single skin and metal flues may need a suitable adapter.
Further advice may be obtained from Ideal Boilers.
Super Plus -
400/4
500/5
4
5
400
500
1364.8
1706.0
2047.2
471
588
1607.0
2006.2
2408.8
44.2
55.1
1558.7
1945.8
2336.4
218
273
463
578
8.6
10.8
113.6
142.0
98 (39)
98 (39)
98 (39)
1.6 (5)
1.6 (5)
60 (197)
60 (197)
60 (197)
800
1000
15.1
15.5
6.1
6.2
1900
1900
74.8
74.8
2115
2115
83.25
83.25
990 (39)
990 (39)
990 (39)
208
208
459
459
69.2
69.2
152.5
152.5
49.8
49.8
109.8
109.8
12.6
12.6
27.7
27.7
39.6
49.5
8.7
10.9
506.6
666.2
1116.9
1468.7
1621.3
546.1
715.6
1203.9
1577.7
1752.3
125
125
5
5
2 (2)
450
450
18
18
500
500
19.7
19.7
12.0
12.0
0.47
0.47
2.7 (1.1)
2.7 (1.1)
2.7 (1.1)
Installation and Servicing
600/6
6
600
706
66.2
327
694
12.9
170.4
1.6 (5)
1200
16.0
6.4
1900
74.8
2115
83.25
208
459
69.2
152.5
49.8
109.8
12.6
27.7
59.4
13.1
735.4
794.6
125
5
450
18
500
19.7
12.0
0.47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super plus 400/4Super plus 300/3Super plus 500/5Super plus 600/6Super plus 300/3 alternativeSuper plus 400/4 alternative

Table of Contents