Page 2
FireGenie Remote Control is tested safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation. FireGenie Remote Control is carefully engineered and MUST be installed only as specified. If you modify it or any of its components, you may possibly cause a fire hazard.
TABLE OF CONTENTS Remote Control Keypad ......................4 Remote Control Screen Display (LCD) ................... 4 Remote Control - Basic Functions ................... 5 Switching the Remote ON and OFF .................. 5 Setting Time & Day ......................5 Receiver Operation ......................... 5 Manual Mode .........................
The FireGenie is a custom designed Remote Control system with the following features: * Thermostatic Control; * An Automatic & Manual Mode for controlling unit ON and OFF; * A Program Mode for programming 2 time periods per day for all days of the week.
When “OFF” Mode is selected, the flame will turn OFF. However, the unit can be turned ON or OFF with the standard ON/OFF switch. Remote: When Remote Mode is selected, the Receiver will turn the flame ON or OFF depending on the setting of the Remote Control. FPI FireGenie Remote Control Manual...
“+” and “-” buttons. The LCD will show the following when either the “+” or “-” button is pressed: Room Temperature Temperature Auto Mode normal When “+” or “-” display button is pressed FPI FireGenie Remote Control Manual...
To exit this mode wait approximately 20 seconds after the last button is released or press the ON/OFF button twice to return to the last operating mode. If the Time Periods have not been programmed in the Remote, the display will show the following: Programs have not been set. FPI FireGenie Remote Control Manual...
The On-Time for Time Period 1 will also flash. The “+” and “-” buttons can be used to adjust this time setting. The LCD will show the current setting in Time Period 1 for Monday: Programming of Time Period 1 Time Period 1 On-Time FPI FireGenie Remote Control Manual...
Page 9
Programming the Set Temperature of Time Period 1 Press and release the PROG button again to program the Set Temperature. Use the “+” and “-” buttons to adjust the temperature setting. Time Period 1 Set Temperature Programming of Time Period 1 FPI FireGenie Remote Control Manual...
Page 10
Press and release the PROG button again to program the Off-Time of Time Period 2. Use the “+” and “-” buttons to adjust this time setting. The LCD will show the following: Programming of Time Period 2 Time Period 2 Off-Time FPI FireGenie Remote Control Manual...
Page 11
7b) Alternatively, Copy Programs Over to the Other Days Pressing and holding the PROG button for 2 seconds or longer will initiate the copying process. The next Day of Week flashes Time Period 1 Setting of Monday FPI FireGenie Remote Control Manual...
Page 12
There are 2 ways to exit Program Mode; 1) The Remote will automatically exit the Program mode 20 seconds after the last button is released or 2) By pressing the ON/OFF button twice, the remote will return to the last operating mode. FPI FireGenie Remote Control Manual...
Refer to the unit instruction manual for wiring details. Installing the Receiver to a Wall Mount a. Secure the Receiver to the wall receptacle box. b. Use the screws provided to secure the face plate to the Receiver. FPI FireGenie Remote Control Manual...
Page 14
6) Re-install battery pack and control switch by reversing steps 2 and 1 only. Receiver Bracket NOTE: After this step, installation of the E21 differs from the rest of the units. Please follow steps specified for the E21. FPI FireGenie Remote Control Manual...
Page 15
7) Secure heat shield with 2 screws as shown below. 5) Place remote receiver under firebox. Remote Firebox Receiver 8) Ensure wires do not touch base of firebox. 6) Place heat shield over receiver. 9) Re-install bottom glass trim. Heat Shield Remote Receiver FPI FireGenie Remote Control Manual...
2:00 pm whereas Time Period 2 is programmed to commence at 1:00 pm, the following will occur: Time Period 1 On-Time Off-Time 8:00 am 2:00 pm 1:00 pm 4:00 pm On-Time Off-Time Time Period 2 Operates in Time Period 1 Setting Operates in Time Period 2 Setting FPI FireGenie Remote Control Manual...
“LC” momentarily indicating the ID codes have been transmitted. 5. Release both the PROG and PRESET buttons. 6. The screen display will revert back to the normal off mode display. NOTE: This must only be performed by a qualified installer. FPI FireGenie Remote Control Manual...