Digital Fiber Sensor Amplifier FX-305(P)
Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet standards, such as OSHA, ANSI or IEC etc.,
WARNING
for personnel protection applicable in each region or country.
For further details on the fiber sensor amplifier, please refer to 'Panasonic
Industrial Devices SUNX website' or contact our office.
1

SPECIFICATIONS

Type
NPN output
Item
Model No.
FX-305
Supply voltage
12 to 24V DC 10% Ripple P-P 10% or less
Power consumption
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
(Note 2)
ECO mode: 600mW or less (current consumption 25mA or less at 24V supply voltage)
NPN open-collector transistor
Maximum sink current: each 50mA (Note 1)
Output
Applied voltage: 30V DC or less
(Output 1, Output 2)
(between output and 0V)
Residual voltage: 1.5V or less
[at each 50mA (Note 1) sink current]
Output operation
Light-ON or Dark-ON, selectable with jog switch
Short-circuit protection
H-SP: 65 s or less, FAST: 150 s or less, STD: 250 s or less
Response time
STDF: 700 s or less, LONG: 2.5ms or less, U-LG: 4.5ms or less
selectable with jog switch
Display
2-level teaching / Limit teaching / Full-auto teaching / Max. sensitivity teaching
Normal mode
/ Manual adjustment
Window comparator
Teaching (1-level / 2-level / 3-level) / Manual adjustment
mode
Fine sensitivity
adjustment function
Incorporated with variable ON-delay / OFF-delay / ONE-SHOT / ON-
delay OFF-delay / ON-delay ONE-SHOT timer, switchable either
Timer function
effective or ineffective (Timer: approx. 0.5 to 9999ms)
Interference prevention
Incorporated [up to four fibers can be mounted adjacently (However,
function (Note 2) (Note 3)
U-LG mode is eight fibers, H-SP mode is two fibers.)]
-10 to +55
Ambient temperature
if 8 to 16 units are connected in cascade: -10 to +45 )
(No dew condensation or icing allowed), Storage: -20 to +70
Ambient humidity
Emitting element
Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Material
Press switches: Acrylic, Jog switch: Heat-resistant ABS
Weight
Accessory
Notes: 1)
50mA per output. 25mA if five, or more, amplifiers are connected in cascade.
2)
When the interference prevention function '
becomes double. Furthermore, take care that the response time also becomes double.
For the setting method, refer to '
3)
When the power supply is switched on, the light emission timing is automatically set for
interference prevention.
4)
The cable for amplifier connection is not supplied as an accessory. Make sure to use the
optional quick-connection cables given below.
Main cable (4-core): CN-74-C1 (cable length 1m), CN-74-C2 (cable length 2m)
CN-74-C5 (cable length 5m)
Sub cable (2-core): CN-72-C1 (cable length 1m), CN-72-C2 (cable length 2m)
CN-72-C5 (cable length 5m)
2
MOUNTING
How to mount the amplifier
Fit the rear part of the mounting section of the amplifier
on a 35mm width DIN rail.
Press down the rear part of the mounting section of the
unit on the 35mm width DIN rail and fit the front part of
the mounting section to the DIN rail.
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the amplifier to remove it.
Note:
Take care that if the front part is lifted without pushing the
amplifier forward, the hook on the rear portion of the mounting section is likely to break.
How to connect the fiber cables
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
Snap the fiber lock lever down.
Insert the fiber cables slowly into the inlets until they stop. (Note 1)
Return the fiber lock lever to the original position, till it stops.
Notes: 1)
In case the fiber cables are not inserted to a position where they
stop, the sensing range reduces. In case of a flexible fiber, take
care that it may bend inside the amplifier, during insertion.
2)
With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2,
insert the single-core fiber cable into the beam-emitting inlet and
the multi-core fiber cable into the beam-receiving inlet. If they are
inserted in reverse, the sensing accuracy will deteriorate.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
INSTRUCTION MANUAL
MJE-FX305 No.0034-49V
PNP output
FX-305P
PNP open-collector transistor
Maximum source current: each 50mA (Note 1)
Applied voltage: 30V DC or less
(between output and +V)
Residual voltage: 1.5V or less
[at each 50mA (Note 1) source current]
Incorporated
4 digit red LED display
Incorporated
(If 4 to 7 units are connected in cascade: -10 to +50 ,
35 to 85% RH, Storage: 35 to 85% RH
Red LED (modulated)
20g approx.
FX-MB1 (Amplifier protection seal): 1 set
' is set, the number of mountable fibers
13
PRO MODE PRO5 mode setting'.
35mm width DIN rail
Fiber
lock lever
3
CAUTIONS
This product has been developed / produced for industrial use only.
When the emission halt of the emitting power switching function is set from 'OFF' to 'ON', the
output may be unstable. Do not use the output control for 0.5 sec. after starting emission.
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the sensor may get burnt or damaged.
In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity
of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Make sure to use the optional quick-connection cable for the connection of the amplifier.
Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if 9 to 16 units are connected
in cascade: 20m) is possible with 0.3mm
wiring as short as possible. Furthermore, take care that cable extension increases the residual voltage.
This sensor is suitable for indoor use only.
Avoid dust, dirt, and steam.
Take care that the product does not come in contact with water, oil, grease, organ-
ic solvents, such as, thinner, etc., strong acid or alkaline.
This sensor cannot be used in an environment containing inflammable or explosive gases.
Never disassemble or modify the sensor.
4
CASCADING
Make sure that the power supply is off while adding or removing the amplifiers.
Make sure to check the allowable ambient temperature, as it depends on the
number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching condition or
the amplifiers are mounted close to each other in cascade, fit them between the
optional end plates (MS-DIN-E) mounted at the two ends.
When connecting amplifiers not close to each other in parallel, be sure to mount the option-
al end plate (MS-DIN-E) at both sides of each amplifier or affix the communication window
seal of the accessory amplifier protection seal (FX-MB1) to the communication window.
Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)
When connecting more than two amplifiers in cascade, use the sub cable (CN-72-C )
as the quick-connection cable for the second amplifier onwards.
The settings other than the interference prevention function cannot be transmitted
between this product and other digital fiber amplifiers. Therefore, in case both mod-
els of amplifiers are mounted in cascade, be sure to mount identical models togeth-
er. However, the interference prevention function is not incorporated in the
FX-301(P)-HS and FX-303(P). Take care when the sensors are mounted in cascade.
The communication function of this product and that of the FX-301(P)-F is differ-
ent. If these models are mounted in cascade, affix the accessory amplifier protec-
tion seal (FX-MB1) to the communication windows of the amplifiers.
For mounting and removing the amplifier, refer to '
Cascading method
Mount the amplifiers, one by one,
on the 35mm width DIN rail.
Slide the amplifiers next to each
other, and connect the quick-con-
nection cables.
Mount the optional end plates
(MS-DIN-E) at both the ends to hold
the amplifiers between their flat sides.
Tighten the screws to fix the end
plates.
Dismantling
Loosen the screws of the end plates.
Remove the end plates.
Slide the amplifiers and remove
them one by one.
5
I/O CIRCUIT DIAGRAMS
NPN output type
D
1
T
r1
T
r2
Internal circuit
PNP output type
Z
T
r3
T
r4
D
2
Internal circuit
Fiber
Notes: 1)
The quick-connection sub cable does not have +V (brown) and 0V
(blue). The power is supplied from the connector of the main cable.
2)
25mA max. if five, or more, amplifiers are connected in cascade.
Symbols...D
, D
1
2
Z
, Z
D1
T
, T
r1
r2
T
, T
r3
r4
2
, or more, cable. However, in order to reduce noise, make the
Main cable (CN-74-C )
(optional)
End plates (MS-DIN-E)
(optional)
Terminal No.
Color code of quick-connection cable
(Brown) +V (Note 1)
1
Load
(Black) Output 1
3
50mA max.
(White) Output 2
Z
D1
4
50mA max.
Z
D2
2
(Blue) 0V (Note 1)
Users' circuit
Terminal No.
Color code of quick-connection cable
(Brown) +V (Note 1)
1
50mA max.
D3
3
Z
(Black) Output 1
50mA max.
D4
4
(White) Output 2
Load
2
(Blue) 0V (Note 1)
Users' circuit
: Reverse supply polarity protection diode
, Z
, Z
: Surge absorption zener diode
D2
D3
D4
: NPN output transistor
: PNP output transistor
MOUNTING'.
2
Sub cable (CN-72-C )
(optional)
Slide
End plates (MS-DIN-E)
(optional)
Slide
Load
+
12 to 24V DC
(Note 2)
10%
-
(Note 2)
(Note 2)
+
12 to 24V DC
(Note 2)
10%
-
Load
Terminal arrangement
diagram
+V
Output 1
Output 2
0V

Advertisement

loading

Summary of Contents for Panasonic FX-305

  • Page 1: Specifications

    MJE-FX305 No.0034-49V Verify that the supply voltage variation is within the rating. Thank you very much for purchasing Panasonic products. Please read this Instruction Take care that if a voltage exceeding the rated range is applied, or if an AC power Manual carefully and thoroughly for the correct and optimum use of this product.
  • Page 2: Operation Procedure

    PART DESCRIPTION TEACHING MODE MODE indicator / L/D ON (Yellow) Output 1 operation indicator Output 2 operation In case of teaching in the window comparator mode, set the detailed settings in (Orange) indicator (Orange) MODE indicator / TIMER (Yellow) PRO6 beforehand. For the settings, refer to ' PRO MODE PRO6 mode setting'.
  • Page 3 Press Jog switch in the object present condition. If the For details of the settings and the setting procedure of the PRO mode, refer to teaching is accepted, the read incident light intensity blinks in 'Panasonic Industrial Devices SUNX website' or contact our office. the digital display. Press PRO settings can be done when MODE indicator / PRO Press Jog switch in the object present condition.
  • Page 4 PRO5 mode setting The 0-ADJ setting function in this product was removed from production starting May, 2005. Turn Hysteresis: Small Press Hysteresis: Standard Press Press Press Press Hysteresis: Large Turn (Blinking) Turn (Note 1) Press Press Turn Amount of shift: 15% approx. Turn Select the desired code : Confirmed...

This manual is also suitable for:

Fx-305p