Error Items And Diagnostic Codes; Alignment And Adjustments - Samsung DV338 Technical Information

Clothes dryer
Table of Contents

Advertisement

ALIGNMENT AND ADJUSTMENTS

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer
before servicing, unless testing requires power.

ERROR ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5sec and con
tinuously show one of the Error Displays from the following errors.
Error Display
LED
LCD
tS
tO
dO
dF
bE
od
hE
Et
FE
Technical_information-02365B.ind2 2
WARNING
Trigger
The Thermistor
resistance is very low or
high.
Running the dryer with
door open
Invalid state for more
than 256 milliseconds
Invalid state of key
circuit short for 75secs
Invalid Dry time in
excess Dry time
Invalid heating Temp in
running the dryer
Invalid state of Eeprom
communication
Invalid power source
Frequency
2
Action Taken
Check for :
- Clogged lint screen
- Restricted vent system.
- Check Thermistor resistance.
Check for :
- Close the door, and run the
dryer
- Loose or open wire terminals
in Door sense circuit.
Check for :
- Loose or open wire terminals
in Door
sense circuit.
Check for :
- Display PCB key circuit short
or not
Check for :
- Sensor bar Open
- Using Adjust time Up exces-
sively
Check for :
- Restricted vent system.
- Check Thermistor resistance.
Check for :
- PCB on Eeprom circuit
Check for :
- Not using regular power
source frequency
- Invalid power frequency sense
circuit
2008-06-25 ¿ÀÈÄ 5:24:23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv438Dv448Dv438aer

Table of Contents