Download Print this page
Oregon Scientific BAR800A User Manual
Oregon Scientific BAR800A User Manual

Oregon Scientific BAR800A User Manual

Slim weather box
Hide thumbs Also See for BAR800A:

Advertisement

Quick Links

LOCATION
Clock / alarm area
Outdoor sensor area
Slim Weather Box
REMOTE SENSOR INSTALLATION
Model: BAR800 / BAR800A
1. Slide open the battery door.
2. Slide channel switch to channel 1.
USER MANUAL
3. Select EU/UK. (RTGN318D only)
4. Insert the battery, matching the polarities (+ / -).
EN
5. Press RESET after each battery change.
OVERVIEW
6. Close the battery door.
FRONT VIEW
The sensor reception icon shows the status:
ICONS
1
2
4
3
5
6
NOTE
If no sensor is found, press and hold
on the main unit.
NOTE
After every sensor initialisation, the main unit may
take up to 30 minutes to receive the time from the sensor.
7. Secure the sensor in the desired location using the
wall mount hole or double sided adhesive tape.
1.
Indicate outdoor sensor reception status
For best results:
2. Next 12 -24 hour weather forecast
Place the sensor within 30 m (100 ft) of the main unit.
3.
Radio controlled clock reception icon
Place the sensor out of direct sunlight and moisture.
4. Outdoor Temperature / Humidity
Position the sensor so that it faces the main unit,
5. Indoor Temperature / Humidity
minimizing obstructions such as doors, walls and
6. Clock with seconds / weekday and Calendar
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic / electronic objects.
BACK VIEW
Position the sensor close to the main unit during cold
1
2
34 5
6
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
TIP
The transmission range may vary depending on
many factors. You may need to experiment with various
locations to get the best results.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock
automatically with a clock signal received from provided
remote sensor.
To enable / disable signal reception:
Press and hold
reception.
1. Battery compartment
NOTE
Reception takes 2-10 minutes. If the signal is
2.
/
increase / decrease value of the setting;
weak, it can take up to 24 hours to get a valid signal.
enable / disable clock reception
3. Wall mount hole
Clock signal reception indicator:
4. RESET: Reset unit to default settings
STRONG SIGNAL
5. MODE: Change display; set clock
6. °C / °F: Select temperature unit
REMOTE SENSOR
NOTE Clock reception is dependent on the successful
FRONT VIEW
BACK VIEW
transmission of data from remote sensor.
displayed, press RESET on sensor and press
5
on the main unit and ensure sensor
successfully logged.
1
MANUALLY SET CLOCK
2
6
To set the clock manually, disable the clock signal
3
reception first.
4
1. Press and hold MODE.
2. Press
1. RESET: Reset unit to default settings
3. Press MODE to confirm.
2. EU / UK Switch (RTGN318D sensor only)
3. Channel Switch
The settings order is: time zone, 12/24 hr format, hour,
4. Double sided adhesive tape
minute, year, calendar mode (month – day / day – month),
5. Wall mount hole
month, day and language.
6. Battery compartment
Time zone offset sets the clock +/- 23 hours from the
received clock signal time.
GETTING STARTED
MAIN UNIT INSTALLATION
NOTE
If you enter + 1 in the time offset setting, this will
give you your local time plus one hour. If you are in the US
1. Remove the battery compartment cover.
(BAR800A) set the clock to:
2. Insert the batteries, matching the polarities.
0 for Pacific time
3. Press RESET after each battery change.
+2 for Central time
NOTE
Batteries should not be exposed to excessive heat
such as sunshine or fire.
NOTE
The language options are English (E), German
MEANING
(D), French (F), Italian (I), and Spanish (S).
Main unit batteries low
To select clock display mode:
Sensor batteries low
Press MODE to toggle between clock with seconds, clock
with weekday and calendar.
WEATHER FORECAST
This product forecasts the next 12-24 hours
within a 30-50 km (19-31 mile) radius.
Sunny
Partially Cloudy
MEANING
Cloudy
Main unit is searching for
sensor(s)
Rainy
A sensor channel has been
found and logged on.
Snowy
No sensor found
TEMPERATURE
To toggle temperature unit: Press °C / °F.
and
RESET
Press RESET to return to the default settings.
SPECIFICATIONS
MAIN UNIT
TYPE
DESCRIPTION
142 x 10 x 125mm
L x W x H
(5.59 x 0.39 x 4.92 in)
150 g (5.29 oz)
Weight
without battery
Power
2 x CR2032 batteries
REMOTE RF CLOCK THERMO HYGRO SENSOR
TYPE
DESCRIPTION
64 x 25 x 98 mm
L x W x H
(2.52 x 0.98 x 3.86 in)
80 g (2.8 oz)
Weight
without battery
-30°C to 70°C
Temperature range
(-22°F to 158°F)
Resolution
0.1°C (0.2°F)
Weather Forecast
75%
Accuracy
to enable or
to disable signal
Signal frequency
433 MHz
Transmission range
30 m (100 ft) unobstructed
No. of channels
5
Power
1 x UM-3 (AA) 1.5 V batteries
WEAK / NO SIGNAL
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
If
is
it, dry it immediately with a soft, lint-free cloth.
and
Do not clean the unit with abrasive or corrosive materials.
has been
Do not tamper with the unit's internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the actual
display.
When disposing of this product, ensure it is collected
separately for special treatment.
/
to change the settings.
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before first use.
NOTE
The technical specifications for this product and
+1 for Mountain time
the contents of the user manual are subject to change
+3 for Eastern time
without notice.
NOTE
Features and accessories will not be available in
all countries. For more information, please contact your
local retailer.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products.
If you're in the US and would like to contact our Customer
Care department directly, please visit:
of weather
www2.oregonscientific.com/service/support.asp
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp.
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Slim Weather
Box (model: BAR800 / BAR800A) is in compliance with
the essential requirements and other relevant provisions
of Directive 1999/5/EC. A copy of the signed and dated
Declaration of Conformity is available on request via our
Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland
CH
and Norway
N
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
WARNING
Changes or modifications not expressly
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE
This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician
for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact
for support or sales. Please visit our website at www2.
oregonscientific.com/service for all enquiries.
We
Name:
Oregon Scientific, Inc.
Address:
19861 SW 95
th
Ave.,Tualatin,
Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
BAR800 / BAR800A
Product Name:
Slim Weather Box
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung
Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: 1) This device may
not cause harmful interference. 2) This device must accept
any interference received, including interference that may
cause undesired operation.
Station Météo Format CD
REMARQUE
excessive comme les rayons du soleil et le feu.
Modèle: BAR800 / BAR800A
EMPLACEMENT
MANUEL DE L'UTILISATEUR
Zone horloge / alarme
FR
Zone de la sonde
VUE D'ENSEMBLE
extérieure
FACE AVANT
INSTALLATION DE LA SONDE SANS FIL
1. Ouvrez le couvercle du compartiment des piles.
1
2. Positionnez l'interrupteur de canal sur le canal 1.
3.
Sélectionnez EU/UK (modèle RTGN318D uniquement).
2
4. Insérez la pile, en respectant les polarités (+/-).
4
5. Appuyez sur RESET après chaque changement de
3
piles.
5
6. Fermez le couvercle du compartiment des piles.
6
L'icône de réception de la sonde vous indique le statut
de la transmission:
ICONES
1.
Indique l'état de réception de la sonde extérieure
2. Prévision météo des 12-24 prochaines heures
3.
Icône de réception de l'horloge radio-pilotée
4. Température/Humidité extérieure
5. Température/Humidité intérieure
REMARQUE
Horloge avec affichage des secondes / jours de la
6.
et maintenez la touche
semaine et calendrier
REMARQUE
VUE ARRIÈRE
l'appareil principal peut prendre jusqu'à 30 minutes pour
1
2
34 5
6
recevoir l'heure depuis la sonde.
7. Sécurisez la sonde à l'emplacement choisi, en utilisant
la fixation murale ou le ruban adhésif double face.
Pour obtenir de meilleurs résultats :
Positionnez la sonde à 30 m maximum (100 pieds) de
l'appareil principal.
Ne placez pas la sonde directement face aux rayons
du soleil ou en contact avec des matières humides.
Positionnez la sonde pour qu'elle soit face à l'appareil
principal, en minimisant les obstacles tels que porte,
murs et meubles.
Dirigez la sonde directement vers le ciel, éloignée des
objets métalliques / électroniques.
Positionnez la sonde à proximité de l'appareil
principal pendant les mois d'hiver puisque le gel
peut endommager le fonctionnement des piles et la
transmission du signal.
1. Compartiment des piles
2.
/
Augmente / diminue les valeurs d'un
ASTUCE
réglage ; active / désactive la réception de l'horloge
fonction de nombreux facteurs. Il peut être nécessaire
3. Trou de fixation murale
d'essayer plusieurs emplacements pour obtenir les
meilleurs résultats.
4. RESET (REINITIALISER) : Réinitialise l'appareil aux
réglages par défaut
5. MODE: Permet de modifier l'affichage de l'horloge et
HORLOGE
de régler l'horloge
RECEPTION DE L'HORLOGE
6. °C / °F: Permet de sélectionner l'unité de mesure de la
température
Ce produit est conçu pour synchroniser automatiquement
l'horloge avec le signal radio reçu de la sonde sans fil
fournie.
SONDE SANS FIL
FACE AVANT
FACE ARRIERE
Activer / désactiver la réception du signal :
Maintenez le bouton
pour désactiver la réception du signal.
5
REMARQUE
1
signal est faible, cela peut prendre jusqu'à 24 heures pour
obtenir un signal valable.
2
6
Indicateur de réception du signal de l'Horloge :
3
4
SIGNAL FORT
1. RESET (REINITIALISER) : Réinitialise l'appareil aux
réglages par défaut
REMARQUE
2. Bouton EU / UK (capteur RTGN318D)
bonne transmission des données émises depuis la sonde
3. Interrupteur de canal
sans fil.
Si
4. Ruban adhésif double face
sonde et sur
5. Trou de fixation murale
vous que la sonde extérieure
6. Compartiment des piles
REGLER MANUELLEMENT L'HORLOGE
POUR COMMENCER
Pour régler manuellement l'horloge, vous devez, tout
INSTALLATION DE L'APPAREIL PRINCIPAL
d'abord, désactiver la réception du signal.
1. Retirez le couvercle du compartiment des piles.
1. Appuyez et maintenez la touche MODE.
2. Insérez les piles, en respectant les polarités.
2. Appuyez sur
3. Appuyez sur RESET après chaque changement de
3. Appuyez sur MODE pour confirmer.
piles.
N'exposez pas les piles à une chaleur
SIGNIFICATION
Piles faibles (Appareil
principal)
Piles du capteur faibles
SIGNIFICATION
L'appareil principal est à la
recherche de la/des sonde(s)
Un canal de la sonde a été
trouvé et est enregistré
Aucune sonde n'est trouvée
Si aucune sonde n'est trouvée, appuyez
et
de l'appareil principal.
A chaque initialisation de la sonde,
La portée de transmission peut varier en
pour activer, ou le bouton
La réception prend 2-10 minutes. Si le
SIGNAL FAIBLE / AUCUN
SIGNAL
La réception de l'horloge dépend de la
s'affiche, appuyez sur la touche RESET de la
et
de l'appareil principal puis assurez-
ait bien été enregistrée.
/
pour modifier les réglages.

Advertisement

loading

Summary of Contents for Oregon Scientific BAR800A

  • Page 1 Hereby, Oregon Scientific, declares that this Slim Weather ICONS MEANING Cloudy piles. Box (model: BAR800 / BAR800A) is in compliance with Main unit is searching for 6. Fermez le couvercle du compartiment des piles. the essential requirements and other relevant provisions sensor(s) Rainy of Directive 1999/5/EC.
  • Page 2 Si está en los EEUU sans la permission du fabriquant. fabricante para obtener más información. 2. Deslice el Interruptor al canal 1. (sólo BAR800A) configure el reloj tal y como se indica a • Ne pas jeter les piles usagées dans les containers •...

This manual is also suitable for:

Bar800