Panphonics AA-160e / AA-160mm amplifier
Remote Control (for advanced users)
AA-160 series amplifier can be connected into the standard Local Area Network (LAN)
for controlling the parameters of the AA-160 series amplifier remotely. For handling
these features some networking experience is required. If you are connecting the
device into an already existing Network, please consult the Network administrator at
the first place.
The remote control from the Network makes it possible to adjust the volume or put
the amplifier into the standby mode or back into the operation. There are also a
great number of sophisticated commands for adjusting the Automatic Volume Control
–algorithm or chance the input sensitivity. The full command reference is at the end
of this manual.
Opening the Remote Connection
For TCP/IP control a telnet connection should be used. The default IP address of the
unit is 192.168.1.111. and network mask is '255.255.255.0' The default Telnet
password is 'passu'*. The device's IP address can be configured by using the following
commands.
*If Mac OS X terminal telnet client is used, the password might be asked twice because of the echoing defaults
ip
Print
current
IP
settings
Usage:
ip
Output:
IP
192.168.1.111
/
255.255.255.0
GW=192.168.1.1
ip
x.x.x.x
Change
current
IP
address,
use
IP
address
0.0.0.0
for
DHCP.
The
new
value
does
not
take
effect
until
"ip
update"
command
is
sent.
After
"ip
update"
a
new
connection
must
be
made
and
settings
saved
by
issuing
"save
setup".
If
the
new
settings
are
not
saved
after
"ip
update"
the
unit
will
reboot
after
about
5
minutes
and
return
back
to
the
old
settings.
Usage:
ip
192.168.1.111
Output:
OK
ip
mask
y.y.y.y
Change
current
subnet
mask
settings.
The
new
value
does
not
take
effect
until
"ip
update"
command
is
sent.
After
"ip
update"
a
new
connection
must
be
made
and
settings
saved
by
issuing
"save
setup".
If
the
new
settings
are
not
saved
after
"ip
update"
the
unit
will
reboot
after
about
5
minutes
and
return
back
to
the
old
settings.
Usage:
ip
mask
255.255.255.0
Output:
OK
ip
gw
z.z.z.z
Change
current
gateway
settings.
The
new
value
does
not
take
effect
until
"ip
update"
command
is
sent.
After
"ip
update"
a
new
connection
must
be
made
and
settings
saved
by
issuing
"save
setup".
If
the
new
settings
are
not
saved
after
"ip
update"
the
unit
will
reboot
after
about
5
minutes
and
return
back
to
the
old
settings.
Usage:
ip
gw
192.168.1.1
Output:
OK
Sound Shower AA-160e / AA-160mm Operation Manual v.2.0 26.3.2012 ©