User Settings Menu

Setting Selection
fan
heat / cool (either heat
pump, gas or electric
heating is selected)
cool only (option only
appears if no heating
equipment is avail able or
configured)
humidity - Allows selection
of dehumidification. Option
only available if enabled in
installer settings.
Table 3. User Settings (General)
Function
Description
See "Fan Operation" on page 6.
normal
Heats home to desired tempera ture setting. Options are on or off.
If system is two-stage heating or cooling, then 2nd stage is locked in
comfort
until demand is satisfied.
Bypasses the first stage of heating (any stage[s] of heat pump heating)
emergency
and goes directly to the heat stage used for maximum heating to more
heat
quickly warm a very cold house.
Heating limit with a default of 0°F. Range is 45°F to 90°F
set point
range
Cooling limit with a default of 45°F. Range is 45°F to 99°F
set point
Cooling limit with a default of 45°F. Range is 45°F to 99°F
range
Options are ON and OFF. Allows dehumidify adjustment setting
dehumidify
between 45% to 60%. Default is 50%.