Mount the reducer to the body of the vehicle in the engine compartment, never on the engine!
Mount the reducer so that it is easy to adjust the pressure.
Install the supplied 8 mm threaded end in the back cover of the reducer.
Mount the reducer as shown in the drawing.
Mount the reducer on a bracket and bolt on with a M8x1 nut.
The LPG lock-off valve can be installed in different positions. Do not damage the O-rings when
rotating the lock-off valve. See picture for torque moment.
The reducer is connected to the heating system circuit by couplings between the coolant fluid
hoses: dependant on the converted vehicle the reducer is placed in series or in parallel with the
heating system.
Overpressure 5mm relief hose : connect to the intake manifold.
No component of the LPG-system shall be located within 100 mm of the exhaust or similar heat
source, unless such components are adequately shielded against heat.
The pressure can be adjusted with the adjusting screw (Allan screw) in the front cover.
Seal the adjusting screw, with the sticker, in the front cover of the reducer after adjusting the
pressure.
Standard reducer, 6 mm LPG pipe, used for engines with a HP up to 135 kW ( 180 HP ).
High Output reducer, 8 mm LPG pipe, used for engines with a HP over 135 kW ( 180 HP ).
Use a High Output MAP reducer on blown engines ( turbo / compressor )

The Prins LPG reducer

mounting positions
NO
threat locking compound allowed !!
Copyright ©
Prins Autogassystemen B.V.
2013