When connecting or disconnecting electrical wiring, always switch off the power supply by disconnecting the vehicle's battery. Assembly of ValveCare-DI device with non-original parts, which have not been checked and recommended by Prins, is not allowed and may cause material damages for which Prins cannot be held liable.
For maintenance instructions and filter registration also see the Driver’s Guide. Prins Autogassystemen is not responsible for any damages to people or objects as a result of changes to Prins products. Power and fuses: ...
General manual ValveCare-DI Introduction Despite the name ValveCare-di suggests that the system can only be installed with VSI-DI, it can certainly also be combined with VSI-2.0 MPI and Direct LiquiMax Gen3. The ValveCare-DI system is a full electronic sequential regulated additive dosing system suitable for direct injected and port gas injected engines.
The consumption of the additive has a ratio of 1 litre additive on 1000 litre LPG. After 100l gas the injected additive should be 100ml. In case the additive reservoir is empty, the Prins switch will indicate a blue exclamation mark (blinking), and the engine can run another 4 hours on LPG.
Wiring loom The wiring loom has 3 super seal connectors for connecting the dosing unit and additive reservoir. The other ends should be connected (soldered) to the Prins wiring loom/car wiring, according to the electrical diagram. Add the extra 1K8 resistor for the VSI-2.0 MPI systems, like described in the wiring diagram.
Page 11
In case of a 3 or 5 cylinder engine, outlet 4 and 6 should not be used. In the ValveCare-DI software, the right settings should be made. Prins advises to use a small piece of 4mm PA hose, melted together, to plug of the unused Remark! outlet.
Supported software ValveCare-DI is supported from Application software number 1055. Check this version before installing the ValveCare-DI system. When the software number does not match, flash the AFC with the latest online firmware. Contact your importer / distributer when the Application software number still does not match.
PAGE 13 General manual ValveCare-DI 12.3 Advanced Calibration parameters Check and set the ValveCare-DI parameters like described in the table below Remark Name ValveCare ValveCare-DI Unit 25764 System AdditiveDosingUnitT ype ValveCare ValveCare DI Only VSI-2.0 MPI AD 4 Sensor Selection...
Load the latest online firmware into the AFC. Check Application software number. (≥1055). Download the import file (ppcf) from the members Area – Diagnostic Software – ValveCare. Use the Prins AFC Software v2 to import the file into the AFC. Set Advanced Calibration Parameters...
Load the latest online firmware into the AFC. Check Application software number. (≥1055). Download the import file (ppcf) from the members Area – Diagnostic Software – ValveCare. Use the Prins AFC Software v2 to import the file into the AFC. Set Advanced Calibration Parameters...
PAGE 16 General manual ValveCare-DI 12.7 VSI-2.0 DI – AFC V2.x 12.7.1 Additional parts No additional parts needed to install the ValveCare-DI system 12.7.2 Wiring diagram 12.7.3 Connections ValveCare-DI Connection to AFC ValveCare-DI Remark Wiring Wire Color Orange +12V Tank off valve...
PAGE 17 General manual ValveCare-DI 12.8 VSI-3 DI – AFC 3.0 DI 12.8.1 Additional parts No additional parts needed to install the ValveCare-DI system 12.8.2 Wiring diagram 12.8.3 Connections ValveCare-DI ValveCare-DI Connection to AFC Remark Wiring Wire Color Orange...
PAGE 18 General manual ValveCare-DI 12.9 Direct LiquiMax Gen3 12.9.1 Additional parts No additional parts needed to install the ValveCare-DI system 12.9.2 Wiring diagram 12.9.3 Connections ValveCare-DI Connection to AFC ValveCare-DI Remark Wiring Wire Color Orange +12V FMU SUPPLY...
Check if the RPM is stable; input connection Positive Change this value to get a stable RPM 12.10.5 Prins AFC Software V2 setting Online Firmware Load the latest online firmware into the AFC. Check Application software number. (≥1055) Set Advanced Calibration Parameters Name...
PAGE 20 General manual ValveCare-DI ValveCare-DI software and settings All ValveCare-DI modules purchased from Prins have default Prins settings and a special Prins communication software. Please follow the steps to make the system suitable for the Prins system 13.1 ValveCare-DI Software download Download ValveCare-DI configuration tool.
PAGE 22 General manual ValveCare-DI 13.4 Set ValveCare-DI parameters [Configuration] Only the discussed parameters/settings have to be changed. Remark! All other parameters/settings should stay “default” Set the common parameters: Number of cilinders Injector flow fate Turbo charger Only DLM ...
In case of air bubbles, use the ventilation function in the software. Start the engine and switch over to LPG to activate the ValveCare-DI system Manual ventilation function In case the system does not measure pressure built up during operation, the Remark! system automatically start the bleeding process.
Parameters and values are shown at the left side of the “Live data”. At the right the parameters are shown in graph. 1) Indication if the ValveCare-DI unit is active (green = active) 2) Indication if the additive level is okay or low (green = additive level okay) 3) Injection time LPG injector (sanity check) 4) Pump activity ->...
Refill the reservoir The additive reservoir can be re-filled at all times. Only refill with the original blue ValveCare-DI additive. If any other additive is used, Prins can no longer guarantee a proper operation and warranty shall expire directly. The additive can damage rubber or plastic parts. Immediately rinse with plenty Attention! of water in case off any additive is spilled.
4823 ValveCare Communication ValveCare-DI module to the AFC 15.2.2 Read out the diagnostic trouble codes with the Prins AFC Software v2. The AFC3.0 DI monitors the DTC via spare input 3 or AD4. Description Possible solution ValveCare bottle Critical Refill the additive container.