Technical Specifications - Lincoln Electric Vantage 500 Operator's Manual

Hide thumbs Also See for Vantage 500:
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS - VANTAGE® 500 (K2686 -1, K2686-2, K2686-3, K2686-4)
VANTAGE
®
500
Make/Model
Description
4 cylinder
43 HP
PERKINS
1850 RPM
404D-22T
Turbo Charged
water cooled
Diesel Engine
Welding Process
DC Constant Current
DC Pipe Current
Touch-Start™TIG
DC Constant Voltage
Arc Gouging
13,000 Watts Peak / 12,000 Watts Continuous, 60 Hz 120/240 Volts Single Phase
22,000 Watts Peak / 20,000 Watts Continuous, 60 Hz 240 Volts 3 Phase
K2686-1
K2686-2 Tier 4 Interim
K2686-3
K2686-4 Tier 4 Final
INPUT - DIESEL ENGINE
Speed (RPM)
High Idle 1850
Full Load 1850
Low Idle 1400
RATED OUTPUT @ 104° F (40° C) - WELDER
Welding Output
Current/Voltage/Duty Cycle
500A / 40V / 100%
525A / 38V / 60%
300A / 32V / 100%
250A / 30V / 100%
500A / 40V / 100%
525A / 38V / 60%
500A / 40V / 100%
RATED OUTPUT @ 40° C (104° F)
Auxiliary Power
Displacement
cu. in. (ltrs.)
135.6(2.2)
Bore x Stroke inch (mm) (Group 34; 650 Oil: 8.45Qts. (8L)
3.43 X 3.64
(87.1 x 92.5mm)
Output Range
30 TO 525 AMPS
40 TO 300 AMPS
20 TO 250 AMPS
14 TO 40 VOLTS
90 TO 500 AMPS
- GENERATOR
.
(1)
ENGINE
Mechanical Fuel Pump, Auto air bleed
system, Electric shutoff solenoid, Indirect
fuel injection.
A-1
INSTALLATION
Starting
Capacities
System
12VDC Battery &
Fuel: 20 gal.
starter
cold crank amps)
Radiator Coolant:
65 Amp Alternator
11.5 Qts. (10.9L)
W / Built in Regulator
Max. Weld OCV
@Rated Load RPM
60 Volts
60 Volts
(75.7 L)
(2)