AEMC MiniFlex MF 300-6-2-10 User Manual

Flexible ac current sensor

Advertisement

Quick Links

FLEXIBLE
AC CURRENT SENSOR
E N G L I S H
Shop for Data Logging products online at:
User Manual
DataLoggerStore
www.
MiniFlex
MF 300-6-2-10
MF 3000-10-2-1
®
1.800.561.81
.ca

Advertisement

Table of Contents
loading

Summary of Contents for AEMC MiniFlex MF 300-6-2-10

  • Page 1 MiniFlex ® FLEXIBLE  MF 300-6-2-10 AC CURRENT SENSOR MF 3000-10-2-1 E N G L I S H User Manual DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 2 Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications.
  • Page 3: Table Of Contents

    Table of Contents 1. INTRODUCTION ................2 1.1 International Electrical Symbols ..........3 1.2 Definition of Measurement Categories ........3 1.3 Receiving Your Shipment ............4 1.4 Ordering Information ..............4 2. PRODUCT FEATURES ................ 5 2.1 Description ................5 2.2 Features ..................6 2.3 Control Features ...............7 3. SPECIFICATIONS ................8 3.1 Typical Frequency Response Curves ........10 3.1.1 Amplitude Error - Model MF 300-6-2-10 .....10 3.1.2 Amplitude Error - Model MF 3000-10-2-1 ....
  • Page 4: Introduction

    CHAPTER 1 INTRODUCTION WARNING These safety warnings are provided to ensure the safety of person- nel and proper operation of the instrument. • Read this instruction manual completely and follow all the safety information before attempting to use or service this instrument. • Safety is the responsibility of the operator. The MiniFlex must ® be used only by qualified personnel using applicable safety precautions. • Wear protective clothing and gloves as required. • Use caution on any circuit: potentially high voltages and currents may be present and may pose a shock hazard. • Read the safety specifications section prior to using the current probe. Never exceed the maximum voltage ratings given. • ALWAYS de-energize the circuit before wrapping the MiniFlex ® around bare conductors, bus bars, or near live parts. Do not wrap on live conductors.
  • Page 5: International Electrical Symbols

    International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation. This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result.
  • Page 6: Receiving Your Shipment

    Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the car- rier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. Ordering Information MiniFlex Model MF 300-6-2-1 ..........Cat. #2126.81 ® Model MF 3000-10-2-1 ........Cat. #2126.82 MiniFlex ® Both models include a BNC (female)/Banana (male) adapter, 9V battery and a user manual. 1.4.1 Accessories and Replacement Parts Adapter - BNC (female) / 4mm Banana (male) ....
  • Page 7: Product Features

    CHAPTER 2 PRODUCT FEATURES Description The MiniFlex is a compact flexible AC current transformer composed of ® a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes could not be used. In particular, it can be installed in confined spaces, places where access is difficult, or even wrapped around irregular shapes. The MiniFlex is lightweight. It does not use magnetic cores like standard ® transformers. The transformation principle is based on an air core. It pres- ents virtually no load to the system under test, has a low phase shift and excellent frequency response, and cannot be damaged by overloads. The sensor assembly is insulated for 1000V CAT III; 600V CAT IV. The Mini- Flex meets EN 61010 and is CE marked. ® The MiniFlex has an mV output proportional to the current measured ®...
  • Page 8: Features

    Features • Measures from 0.5Arms to 3000Arms (model dependent) • Accuracy 1% of Reading ± 0.25A • TRMS measurements when connected to a TRMS instrument • No core saturation or damage if overloaded • Overrange LED for measurement circuitry • EN 61010; 1000V CAT III; 600V CAT IV; CE Mark • 9V battery for typical 140 hour continuous operation • 20kHz frequency response • Low phase shift for power measurements • Insensitive to DC, measures only AC component on DC + AC signals • Excellent linearity • Lightweight • Sensor is resistant to oils and aliphatic hydrocarbons MiniFlex Flexible AC Current Probe ® DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 9: Control Features

    Control Features Figure 1 1. Flexible sensor 5mm Ø 2. Sensor opening device 3. Shielded cord 4. BNC output connector 5. Red OL (overload) indicator 6. Green ON/OFF indicator 7. Range selection switch: - Model MF 300-6-2-10 (30 / 300A) - Model MF 3000-10-2-1 (300 / 3000A) 8. BNC (female) / Banana (male) connector MiniFlex Flexible AC Current Probe ® DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 10: Specifications

    CHAPTER 3 SPECIFICATIONS REFERENCE CONDITIONS Quantity of influence Reference values Temperature 23 ± 5° C Relative humidity 20 to 75% RH Frequency of the signal measured 40 to 400Hz Type of signal sinusoidal External electric field < 1V/m External DC magnetic field (earth field) <...
  • Page 11 MODEL MF 300-6-2-10 MF 3000-10-2-1 MECHANICAL Module Output Coaxial cable terminated by an insulated female BNC connector Module Dimensions 4.0 x 2.5 x 1.1" (103 x 64 x 28mm) Module Weight 7 oz. (200g) 5mm Ø Sensor Diameter Sensor Length 6"...
  • Page 12: Typical Frequency Response Curves

    Typical Frequency Response Curves 3.1.1 Amplitude Error - Model MF 300-6-2-10 30A Range: 30 % 20 % 10 % -10 % 1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz 300A Range: 30 % 20 % 10 % -10 % 1000 10000 100000 MiniFlex Flexible AC Current Probe ®...
  • Page 13: Amplitude Error - Model Mf 3000-10-2-1

    3.1.2 Amplitude Error - Model MF 3000-10-2-1 300A Range: -1 % -2 % 1000 10000 100000 3000A Range: -1 % 1000 10000 100000 MiniFlex Flexible AC Current Probe ® DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 14: Phase Error - Model Mf 300-6-2-10

    3.1.3 Phase Error - Model MF 300-6-2-10 300A Range: 10 ° 0 ° -10 ° -20 ° -30 ° -40 ° -50 ° -60 ° 1000 10000 100000 3000A Range: 10 ° 0 ° -10 ° -20 ° -30 ° -40 °...
  • Page 15: Phase Error - Model Mf 3000-10-2-1

    3.1.4 Phase Error - Model MF 3000-10-2-1 300A Range: 10 ° 5 ° 0 ° -5 ° -10 ° -15 ° -20 ° -25 ° -30 ° 1000 10000 100000 3000A Range: 10 ° 5 ° 0 ° -5 ° -10 °...
  • Page 16: Frequency Limitation Versus Amplitude

    3.1.5 Frequency Limitation Versus Amplitude 3000A Range: 3500 A 3000 A 2500 A 2000 A 1500 A 1000 A 500 A 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz MiniFlex Flexible AC Current Probe ® DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 17: Operation

    CHAPTER 4 OPERATION Compatibility The MiniFlex is compatible with any multimeter, AC voltmeter, or other ® voltage measuring instrument with an input impedance greater than 1MW. To achieve the best overall accuracy, use the MiniFlex with an AC voltme- ® ter having an accuracy of 0.75% or better. Tips for Making Precise Measurements • When using the MiniFlex with a meter, it is important to select the ® range that provides the best resolution. Failure to do this may result in measurement errors.
  • Page 18: Making Measurements

    Making Measurements • Connect the electronic module to the AC Volt range of a multimeter or measuring instrument. Select the highest range on the MiniFlex ® • Press the sensor’s yellow opening device to open the flexible coil. • Wrap the coil around the conductor to be tested. If possible, within range, select the lowest range to obtain the best resolution. • Do not exceed specified current range for the output. Do not use on selected range if overload LED goes on. • Read the displayed value on the multimeter and divide it by the range selected (i.e. if reading = 2.59V with the 10mV/A output range, the cur- rent flowing through the probe is 2590mV ÷ 10 = 259A).
  • Page 19: Maintenance

    CHAPTER 5 MAINTENANCE Maintenance Warning • For maintenance use only specified replacement parts. • To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so. • To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into the case. • Turn the instrument OFF and disconnect the unit from all the cir- cuits before opening the case. 5.1.1 Battery Replacement The battery must be replaced when the green indicator flashes or remains off when the instrument is switched on. • Disconnect everything connected to the instrument and set the switch to OFF. • Use a screwdriver to unscrew the two screws on the housing. • Replace the old battery with a new one (9V alkaline or lithium bat- tery of type 6LF22). • Close the housing, making sure that it is completely and correctly closed, then screw both screws back in. 5.1.2 Cleaning •...
  • Page 20 DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 21: Limited Warranty

    Instruments, not by the distributor from whom it was pur- ® chased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. ® Full warranty coverage and product registration is available on our website at www.aemc.com/warranty.html. Please print the online Warranty Coverage Information for your records. What AEMC Instruments will do: ® If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC...
  • Page 22 Notes: DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 23 DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...
  • Page 24 08/13 99-MAN 100345 v4 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® DataLoggerStore 1.800.561.81 www. Shop for Data Logging products online at:...

This manual is also suitable for:

Miniflex mf 3000-10-2-1

Table of Contents