ENGLISH
New functions in firmware version 2.00
The following new function has been added in firmware version 2.00.
0 Ambisonic mode added
0 Menu Screen operation added
0 Support for 4-channel poly files added
Ambisonic mode added
The unit must be set to ambisonic mode when using an ambisonic mic to
record.
Ambisonic mode settings
Make ambisonic mode settings on the new
AMBISONICS
page.
REC MODE
This sets the ambisonic recording mode.
options:
OFF
A FORMAT
B FORMAT
,
,
B FORMAT
This sets the recording format, when the REC MODE is set to B FORMAT.
FuMa
AmbiX
options:
,
POSITION
This sets the orientation of the ambisonic mic.
Option
Meaning
UPRIGHT
Use when recording with the mic pointed up
UPSIDEDOWN
Use when recording with the mic pointed down
ENDFIRE
Use when recording with the mic pointed forward
UPRIGHT
UPSIDEDOWN
ENDFIRE
Menu screen changes when ambisonic mode is on
A FORMAT
B FORMAT
When ambisonic mode is set to
or
, the menu screens
shown will change as follows.
0 Menu items shown
Page name
Page name
1
INPUT
9
TIME CODE
2
AMBISONICS MODE
10
SLATE TONE
LEVEL CONTROL
HDMI AUDIO ASSIGN
3
11
OUTPUT LEVEL
METER / TRIM
4
12
5
RECORD
13
POWER MANAGEMENT
6
REC SETTING
14
REMOTE
FILE
SYSTEM
7
15
MEDIA
8
0 Menu items not shown
SEL
item on
INPUT
page
i
IN 1-2
IN 3-4
INPUT is fixed to
and
.
MIXER
page
i
The mixer function is disabled.
PHASE/DELAY
page
i
The mic distance delay compensation and input phase reversal functions
are disabled.
AUTO
item on
LEVEL CONTROL
page
i
The automatic level control function is disabled.
TRIM GANG
page
i
When ambisonic mode is set to
A FORMAT
or
B FORMAT
, operating knob
1 will affect the TRIM values of all inputs (1–4).
i MIC POWER page
PHAN
and
VOLTAGE
phantom power settings from the
MIC POWER
INPUT
are shown on the
page, and the plug-in power function is disabled.
D01334100B
NOTE
i On the following pages, using knob 1 will operate all channels. (There are no
settings for individual channels.)
GAIN
item on
INPUT
page
i
LEVEL CONTROL
LIM
page When the
. item is set to
i
four channels linked.
REC SETTING
SAMPLE
i The
page
item cannot be set to
i If recording is conducted when the
REC SETTING
page
BWF 16bit
BWF 24bit
AMBISONIC
or
, the
page settings will be recorded in XRI
format in the BWF file with the recording data.
REC SETTING
FILE TYPE
i The
page
item options become
(
STEREO
cannot be selected). The default value will be changed from
to
POLY
.
Names of files recorded in ambisonic mode
Files recorded in ambisonic mode will be named in the following manner.
0 When recorded with B Format set to FuMa
TASCAM_FuMaB_0001.wav
Monitoring changes when ambisonic mode is on
When ambisonic mode is set to A FORMAT or B FORMAT, the monitoring that
can be selected will change as follows.
Option
Meaning
Sound in the 45° range in front of the ambisonic mic is
STEREO MIX
converted to stereo for monitoring.
Input sound is monitored from the front/upper left (Front Left
FLU
Up) mic capsules (as seen in UPRIGHT orientation).
Input sound is monitored from the front/lower right (Front Right
FRD
Down) mic capsules (as seen in UPRIGHT orientation).
Input sound is monitored from the back/lower left (Back Left
BLD
Down) mic capsules (as seen in UPRIGHT orientation).
Input sound is monitored from the back/upper right (Back Right
BRU
Up) mic capsules (as seen in UPRIGHT orientation).
W
The B format W audio is monitored.
X
The B format X audio is monitored.
Y
The B format Y audio is monitored.
Z
The B format Z audio is monitored.
CAMERA IN
The CAMERA IN jack signal is monitored.
The input FLU sound is monitored in the left channel and the
FLU+FRD
input FRD sound is monitored in the right channel.
The input BLD sound is monitored in the left channel and the
BLD+BRU
input BRU sound is monitored in the right channel.
Meter display when Ambisonic mode is on
When Ambisonic mode is on, the meters correspond to the audio as shown in
the following table.
1
2
A format
FLU
FRD
B format (FuMa)
W
X
B format (AmbiX)
W
Y
Menu Screen operation added
When the Menu Screen is open, press and hold the MENU button again to return
INPUT
to the
page.
Support for 4-channel poly files added
The
REC SETTING
page
FILE TYPE
item
6ch
option has been changed to
When set to POLY
When the
RECORD
page
MIX
item is set to
OFF
, 4-channel poly files will be
created.
ON
When set to
, 6-channel poly files including the MIX will be created. When
4-channel poly files are created, "_4ch" will be added to the end of the file name
("_6ch" will be added to the end of 6-channel poly files).
page
取扱説明書・追補
ファームウェアV2.00の新機能
ファームウェアV2.00より、次の新機能を追加しました。
0 アンビソニックスモードの追加
0 メニュー画面表示中の操作の追加
0 4ch POLYファイル対応の追加
ON
, it will operate with
アンビソニックスモードの追加
アンビソニックスマイクを使って録音する場合に、アンビソニックスモードを設定す
る必要があります。
アンビソニックスモードの設定
アンビソニックスモードの設定は、追加された "AMBISONICS" ページで行います。
192kHz
.
FORMAT
item is set to
MONO
POLY
and
REC MODE
MONO
アンビソニックスモードの録音モードを設定します。
選択肢: "OFF" 、 "A FORMAT" 、 "B FORMAT"
B FORMAT
録音フォーマットを "B FORMAT" 時の録音フォーマットを設定します。
選択肢: "FuMa" 、 "AmbiX"
POSITION
アンビソニックスマイクの設置方向を設定します。
選択肢
内容
UPRIGHT
マイクを上向きに設定して録音する場合
UPSIDEDOWN
マイクを下向きに設定して録音する場合
ENDFIRE
マイクを前向きに設定して録音する場合
UPRIGHT
UPSIDEDOWN
アンビソニックスモードがオン時のメニュー画面変更
アンビソニックスモードが "A FORMAT" もしくは "B FORMAT" のとき、メニュー
画面の表示が以下のように変更されます。
0 表示されるメニュー項目
ページ名
1 INPUT
2 AMBISONICS MODE
3 LEVEL CONTROL
4 OUTPUT LEVEL
5 RECORD
3
4
6 REC SETTING
BLD
BRU
7 FILE
Y
Z
8 MEDIA
Z
X
0 表示されないメニュー項目
i "INPUT" ページの "SEL" 項目
INPUTは "IN1-2" と "IN3-4" で固定になります。
i "MIXER" ページ
ミキサー機能は、無効になります。
i "PHASE/DELAY" ページ
各マイクの距離の時間差補正機能と入力の位相反転機能は、無効になります。
POLY
.
i "LEVEL CONTROL" ページの "AUTO" 項目
オートレベルコントロール機能は、無効になります。
i "TRIM GANG" ページ
アンビソニックスモードが "A FORMAT" もしくは "B FORMAT" のときは、
つまみ1の操作で1~4全ての入力TRIMが操作されます。
i "MIC POWER" ページ
"MIC POWER" ページのファントム電源設定 "PHAN" 項目と "VOLTAGE" 項
目は "INPUT" ページに表示され、プラグインパワー機能は無効になります。
メモ
i 以下のページは、1つまみにて一括で全てのチャンネルの操作になります(各チャ
ンネルの設定がありません) 。
i "INPUT" ページの "GAIN" 項目
i "LEVEL CONTROL" ページ
"LIM." 項目は、 "ON" のとき4chリンク状態で動作します。
i "REC SETTING" ページの "SAMPLE" 項目にて、 "192kHz" は設定できません。
i "REC SETTING" ページの "FORMAT" 項目を "BWF 16bit" および "BWF 24bit"
にて録音した場合、録音データと一緒に "AMBISONIC" ページの設定がBWFファ
イルにXRI形式で記録されます。
i "REC SETTING" ページの "FILE TYPE" 項目は、 "MONO" か "POLY" の選択に
なります( "STEREO" が選べません) 。初期値が "MONO" から "POLY" に変更
されます。
アンビソニックスモードで録音した時のファイル名
アンビソニックスモードで録音したときのファイル名は、以下のようになります。
0 B Format FuMaで録音した場合
TASCAM_FuMaB_0001.wav
アンビソニックスモードがオン時のモニターの変更
アンビソニックスモードが "A FORMAT" もしくは "B FORMAT" のとき、選択可能
なモニター先が以下のように変更されます。
選択肢
内容
アンビソニックスマイクの音声を前面45度のステレオに変換した
STEREO MIX
音声をモニターします。
マイクをUPRIGHTにしたときの、前方/左上(Front Left Up)
FLU
のマイクカプセルの入力音声をモニターします。
マイクをUPRIGHTにしたときの、前方/右下(Front Right
FRD
Down)のマイクカプセルの入力音声をモニターします。
マイクをUPRIGHTにしたときの、後方/左下(Back Left
BLD
Down)のマイクカプセルの入力音声をモニターします。
マイクをUPRIGHTにしたときの、後方/右上(Back Right Up)
BRU
のマイクカプセルの入力音声をモニターします。
ENDFIRE
W
BフォーマットのWの音声をモニターします。
X
BフォーマットのXの音声をモニターします。
Y
BフォーマットのYの音声をモニターします。
Z
BフォーマットのZの音声をモニターします。
CAMERA IN
モニターのLチャンネルに入力のFLU、RチャンネルにFRDの音声
ページ名
FLU+FRD
をモニターします。
9 TIME CODE
モニターのLチャンネルに入力のBLD、Rチャンネルに入力のBRU
BLD+BRU
10 SLATE TONE
の音声をモニターします。
11 HDMI AUDIO ASSIGN
アンビソニックスモードがオンのときのメーター表示について
12 METER / TRIM
アンビソニックスモードがオンの場合のメーターと音声の対応は、次の表のとおりです。
13 POWER MANAGEMENT
14 REMOTE
Aフォーマット
15 SYSTEM
Bフォーマット(FuMa)
Bフォーマット(AmbiX)
メニュー画面表示中の操作の追加
メニュー画面表示中にMENUボタンを押し続けると、 "INPUT" ページに戻ります。
4ch POLYファイル対応の追加
"REC SETTING" ページの "FILE TYPE" 項目の選択肢について、 "6ch" を "POLY"
に変更しました。
POLYに設定した場合
"RECORD" ページの "MIX" 項目を "OFF" にすると、4ch POLYファイルを作成し
ます。
"ON" にすると、MIXを含む6ch POLYファイルを作成します。
4ch POLYファイルを作成した場合、ファイル名の末尾に「_4ch」が追加されます
(6ch POLYファイルの場合は、今までどおり「_6ch」です) 。
DR-701D
IN端子の信号をモニターします。
1
2
3
4
FLU
FRD
BLD
BRU
W
X
Y
Z
W
Y
Z
X
0318.MA-2487B
Need help?
Do you have a question about the DR-701D and is the answer not in the manual?
Questions and answers