Download Print this page
CAMDEN Sure-Wave CM-330/N Installation Instructions

CAMDEN Sure-Wave CM-330/N Installation Instructions

Battery operated active infra-red hands-free switches

Advertisement

Quick Links

Section 1: General Description
Sure-Wave™ Hands-Free Switch are active infra-red devices
utilizing micro burst sensor technology, designed for use
in ADA compliant automatic door control applications. The
switches eliminate the spread of germs by avoiding physical
contact and offer building occupants greater convenience
when moving through the premises. Sure-Wave™ switches
are available with either stainless steel or impact resistant
polycarbonate faceplates, in narrow (jamb), single gang or
double gang configurations. All models are ROHS compliant
with lead-free construction.
Application
Sure-Wave™ battery powered hands-free switches are
American Disability Act (ADA) compliant, and provide
barrier free access and egress to buildings and washroom
facilities. The rugged construction makes them ideal for
use on low-energy automatic doors, drive-up windows,
and interior and exterior doors in virtually any commercial
(office, retail), institutional (school, hospital or clinic), or
industrial (manufacturing) facility.
Three standard face plate widths are available:
CM-330: 2 ¾" x 4 ½" polycarbonate or stainless steel, fits
on single gang electrical boxes.
CM-330/N: 1 ¾" x 4 ½" polycarbonate or stainless steel, fits
1 ¾" door frames or our CM-23D Jamb box.
CM-330 Battery Operated
Active Infra-red "Hands-Free" Switches
CM-330/W: 4 ½" x 4 ½" polycarbonate or stainless steel,
fits on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face, with the
waving hand symbol (/40), with the waving hand symbol
and words: WAVE TO OPEN (/41) or with the waving hand
icon, wheelchair and words: WAVE TO OPEN (/42).
Section 2: Installation
Mounting
Sure-Wave™ may be mounted in door jambs, single or
double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for
outdoor or wet locations. If using with Automatic doors
install in accordance with ANSI A156.10 / A156.19. Select
from one of the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-330
1a – If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Using the dip switch located on the end of the unit, set
the operating mode. (See Section 4)
3 – Attach the unit to the enclosure using the two #6-32
screws provided.
4 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Page 1 of 4

Installation Instructions

BY CAMDEN

Advertisement

loading

Summary of Contents for CAMDEN Sure-Wave CM-330/N

  • Page 1: Installation Instructions

    CM-330 Battery Operated Active Infra-red “Hands-Free” Switches Installation Instructions BY CAMDEN CM-330/W: 4 ½” x 4 ½” polycarbonate or stainless steel, fits on single gang, double gang or 4 x 4 electrical boxes. All faceplates may be ordered up with a plain face, with the...
  • Page 2 Wall Do not overtighten!! Pairing the CM-330 CM-330 battery operated wireless SureWave™ utilizes our Lazerpoint RF technology and is for use with Camden Flush CM-RX91 or CM-RX92 Lazerpoint receivers. To pair the CM-330 transmitter to a receiver, press the PB1 (or PB2) button on the Receiver using a small blunt object such as a small blade screwdriver or similar.
  • Page 3 CM-330 Battery Operated Active Infra-red “Hands-Free” Switches Installation Instructions Section 3: Applications & Set-up Applications See Diagram 3 for the location of the Dip switches. MOM OP LED Enable MOM OP with Alarm Audio Enable DIP Switch Settings Sounder DIP Switch 1 Activate CM-330 Description...
  • Page 4 CM-330 Battery Operated Active Infra-red “Hands-Free” Switches Installation Instructions 2 " Section 4: System Inspection 38 mm Instructions After the Installation and operational check of the system: 1. Place warning label on the door (as per ANSI A156.10 or A156.19 guidelines). This will advise the person entering the swing side zone that the door will move.