Mitsubishi PLH-3AK.UK Technical & Service Manual page 42

Plh series.
Table of Contents

Advertisement

2-5 Auto vane control
FILTER
CHECK MODE
TEST RUN
WIRED REMOTE
CONTROLLER
Changes by press-
ing the
button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the airflow direction in automatically set to 30°. After, it can be changed to
another direction with
<Auto return>
When 55° or 70° airflow is set with fan speed in LOW, "1Hr" appears right side of the air direction. One hour later the
direction changes to 30 degrees, automatically and "1Hr" disappears.
(2) HEAT operation
At the start-up of HEAT operation, airflow direction depends on the setting of the last operation.
After, it can be changed to another direction with
controller settings under any of the following conditions.
Thermostat OFF
Defrosting
Indoor fan speed EXTRA-LOW in hot adjustment
ADDRESS
UNIT No.
FUNCTION No.
SELECTION No.
˚C
AM
PM
FUNCTION
AM
TEST RUN
PM
CHECK
TEMP.
ON/OFF
PLH-3AK.UK
PLH-3AK
.UK
1
PLH-3AKH.UK
PLH-3AKH
.UK
1
PLH-4, 5, 6AKS.UK
PLH-4, 5, 6AKS
1
PLH-4, 5, 6AKHS.UK
PLH-4, 5, 6AKHS
WIRELESS REMOTE
CONTROLLER
1
30°
2
45° downward
3
55° downward
4
70° downward
5
swing
button on the remote controller.
<How to operate>
To change the air flow direction, press
1
30°
.UK
.UK
1
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from HIGH to LOW during 45°
downward airflow in COOL mode, the direction automat-
ically changes to 30°.
button. The airflow direction shifts to 30° regardless of the remote
42
button.
2
3
4
45°
55°
70°