Installing Batteries

1.
Press the tab of the battery compartment cover and lift it clear.
2.
Remove the battery compartment cover.
3.
Insert the new batteries, ensuring correct polarity.
4.
Close the battery compartment cover; ensuring it is completely and correctly
closed.

Connecting to a Computer

The Model 1227 must be connected to DataView
detailed setup instructions, see the User Manual in the USB drive that comes with the
instrument.) To connect the Model 1227 to your computer:
1.
Install the DataView
Panel as an option (it is selected by default). De-select any Control Panels you
do not need.
2.
If prompted, restart the computer after installation is complete.
3.
Connect the instrument to the computer using a USB cable or pair with
Bluetooth.
4.
Wait for the drivers to install. The drivers are installed the first time the
instrument is connected to the computer. The Windows operating system will
display messages indicating when the installation is complete.
5.
Start the Data Logger Control Panel by double-clicking the Data Logger
shortcut icon
installation.
6.
Click Instrument in the menu bar, and select Add an Instrument.
7.
The Add an Instrument Wizard dialog box opens. This is the first of a series of
screens that lead you through the instrument connection process. The first
screen prompts you to select the connection type (USB or Bluetooth). Choose
the connection type and click Next.
8.
If the instrument is identified, click Finish. The instrument is now
communicating with the Control Panel.
9.
When you are finished, the instrument will appear in the Data Logger Network
branch in the Navigation frame, with a green check mark indicating a successful
connection.
Setting the Instrument's Clock
To ensure an accurate time stamp of measurements recorded in the instrument, set the
instrument's clock as follows:
1.
Select the instrument in the Data Logger Network.
2.
In the menu bar, select Instrument. In the drop-down menu that appears, click
Set Clock.
3.
The Date/Time dialog box appears. Complete the fields in this dialog box. If you
need assistance, press F1.
4.
When you are finished setting the date and time, click OK to save your changes
to the instrument.