  • Page 3: Introduction

    Overview This Tester provides a digital reading of a person’s approximate BAC in seconds. The AlcoHAWK PT750 is powered by a rechargeable lithium battery that in general ® lasts about 200 tests when fully charged. Please read the entire manual before use.
  • Page 4: Effects Of Alcohol

    EFFECTS OF ALCOHOL Dose-Specific Effects Generally no loss of coordination. Slight joy or loss of shyness. Depressant effects are 0.020-0.039% not clear. General feelings of well-being, relaxation, shyness is reduced and sensation of warmth. 0.040-0.069% Joy. Some minor impairment of reasoning and memory. Lowering of caution. Driving skills may be impaired.
  • Page 5 PREPARATION and COMPONENTS DIAGRAM Insert a New Mouthpiece Insert a new mouthpiece firmly into the top of the unit. It should be level when in place. See diagram below.
  • Page 6 BATTERY REPLACEMENT Apply a small amount of pressure on the battery cover located on the back of the unit and push down and away from the unit to release the cover. See the below diagram. Make sure to insert the battery with the proper position of positive (+) and negative (-) as indicated.
  • Page 8: Operation

    OPERATION Wait 20 minutes after subject smokes, eats or drinks before testing. Failure to wait 20 minutes can give wrong BAC readings and damage the sensor. 1. Insert a mouthpiece into the mouthpiece inlet. 2. Push the ON/OFF power switch that is located in the right side under the display window.
  • Page 9 turns off. Try to power on again. 4. After the circling line is on the display for 3 ~ 22 seconds, the test result will be displayed for 20 seconds along with beep sound. - If the test result is over 0.050%BAC(default setting) respectively, “WARN”...
  • Page 10: Read The Results

    READ THE RESULTS The result is an estimate of the subject’s BAC. A breath alcohol tester cannot tell the exact BAC in the blood of the subject. A link between Breath Alcohol Content (BrAC) and BAC depends on many factors, such as temperature and health conditions.
  • Page 11: Error Messages

    ERROR MESSAGES Error Message Cause and Effect Error Message Cause and Effect If the result is The battery higher than voltage is too 0.050% BAC low to perform a “WARN” signal test. Replace is displayed 1.5V Alkaline along with Batteries. “ALARM”...
  • Page 12 Over 500 tests When the the unit shows ambient “CAL”. temperature is Calibration is out of working recommended. temperature Consult to the range (5℃ ~ seller or local 40℃) the unit distributor for shows “OUT” the service. and then turn off. Keep and use the unit within the recommended...
  • Page 13: Precautions

    PRECAUTIONS 1. After drinking, smoking and eating, users should wait at least 20 minutes before testing. 2. Avoid testing in strong winds, in a closed room with a heavy amount of smoke, or where alcohol is present. 3. When the “BAT” signal is on the display, it is advisable to replace 1.5V Alkaline Batteries.
  • Page 14: Specifications

    0 ℃ ~ 40 ℃ Storage Temp. Calibration Every 6 months or after 500 tests Warranty 1 Year Limited Warranty Estimates, results may vary. ACCESSORIES Visit our online store at www.alcohawk.com to purchase: • Mouthpieces • Soft Carrying Pouch • Hard Case...
  • Page 15 If the unit is providing inconsistent results, unusually high or low readings, or no readings at all, a professional needs to recalibrate the unit. For recalibration or support, please visit www.alcohawk.com or call 262-925-0970. During recalibration, a technician will perform a diagnostic check on the unit and reset the baseline sensor values.
  • Page 16: Disclaimer

    3. You must enclose the following with the unit: a. The completed RMA form (available at www.alcohawk.com) b. Your name, return address and description of the problem. (No PO Box) c. Your phone number to reach you during the day.
  • Page 17 impaired by alcohol. Correlation between BrAC and BAC depends on many variables, such as temperature and health conditions of the test subject. A safe or low BAC reading does not mean that the test subject’s physical or mental performance or judgment (including reaction times) can respond to any emergency encountered.
  • Page 18 PERMITTED BY LAW, QUEST IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOSS OF USE; LOSS OF REVENUE OR INCOME; LOSS OF ACTUAL OR ANTICIPATED PROFITS (INCLUDING LOSS OF PROFITS FROM A CONTRACT);...