MNP is a registered trademark of Microcom Inc. IBM PC, AT, XT are registered trademarks of International Business Machine Cor- poration. INSYS®, VCom®, e-Mobility LSG® and e-Mobility PLC® are registered trademarks of INSYS MICROELECTRONICS GmbH. Windows™ is a registered trademark of Microsoft Corporation.
Content Preface ................6 1 .1 Defects Liability Ter ms............... 6 1 .2 Feedback ..................6 1 .3 Marking o f Warnings and Notes ............7 1 .4 Symbols and the For matting in this Manual ..........8 Safety ................
Page 5
Contents Assembly ................27 8 .1 Screw mounting ................28 8 .2 D IN rail mounting ................29 8 .3 Connecting the power supply ............3 0 Commissioning ..............31 Operating Principle............... 34 1 0 .1 Operation via the web interface ............3 4 1 0 .2 Access via HTTPS Protocol ........
The liability of the manufacturer ceases to exist. The regulations of our Delivery and Purchasing Conditions are effective. These can be found on our website (www.insys-icom.de/imprint/) under “General Terms and Conditions“. Feedback We are permanently improving our products and the associated technical docu- mentation.
Preface Marking of Warnings and Notes Symbols and Key Words Danger! Risk of severe or fatal injury One of these symbols in conjunction with the key word Danger indicates an imminent danger. It will cause death or severe injuries if not avoided. Warning! Personal injury This symbol in conjunction with the key word Warning...
Preface Symbols and the Formatting in this Manual This section describes the definition, formatting and symbols used in this manual. The various symbols are meant to help you read and find the information relevant to you. The following text is structured like a typical operating instruction of this manual.
Safety Safety The Safety section provides an overview about the safety instructions, which must be observed for the operation of the product. The product is constructed according to the currently valid state-of-the-art technol- ogy and reliable in operation. It has been checked and left the factory in flawless condition concerning safety.
Safety Permissible Technical Limits The product is only intended for the use within the permissible technical limits specified in the data sheets. The following permissible limits must be observed: The ambient temperature limits must not be fallen below or exceeded. The supply voltage range must not be fallen below or exceeded.
Safety Markings on the Product The identification plate of the product is either a print or a label on a face of the product. Amongst other things, it can contain the following markings, which are explained in detail here. Observe manual This symbol indicates that the manual of the product contains essential safety instructions that must be followed implicitly.
Safety Safety Instructions for Electrical Installation The electrical connection must only be made by authorised expert personnel ac- cording to the wiring diagrams. The notes to the electrical connection in the manual must be observed. Otherwise, the protection category might be affected. The safe disconnection of circuits, which are hazardous when touched, is only en- sured if the connected devices meet the requirements of VDE T.101 (Basic require- ments for safe disconnection).
Safety General Safety Instructions Caution! Electrostatic discharges may damage the product! Damage of the product. Observe the general safety precautions when handling electrostatic-discharge-sensitive parts. Caution! Incomplete voltage isolation! Damage of the product. To isolate the voltage from the device, disconnect any supply circuit with its respective isolation device if a redundant power supply is used.
Page 14
Safety Caution! Short circuits and damage due to improper repairs and modifications as well as opening of maintenance areas! Fire hazard and damage of the product. It is not permitted to open the product for repair or modification exceeding the removal or installation of the designated plug-in cards.
3 years after delivery of our product to the custome r. Requests must be directed to the following address, if possible under specification of the serial number: INSYS MICROELECTRONICS GmbH Hermann-Köhl-Str. 22 93049 Regensburg, Germany Phone +49 941 58692 0 Fax +49 941 58692 45 E-mail: support@insys-icom.de...
Used Open-Source Software Please contact our support department (support@insys-icom.de) for a list of the open-source software used in this product. Alternatively, you’ll find a list of the open-source software in the web interface of the routers under Help -> Licences.
Device Variants Device Variants This manual describes different variants of the industrial router series SCR of INSYS icom. The routers are referred to as SCR in the manual. The routers are: • SCR-E200 (LAN-LAN router without I/Os) • SCR-E300 (LAN-LAN router with I/Os) •...
• Quick Installation Guide • Safety Instructions The scope of delivery does not include optional accessories. Among other things, the following parts are available from your distributor or INSYS icom: • DIN rail adapter • Cellular antennas • Antenna extensions and accessories •...
Technical Information Technical Information The following information applies to all variants of the router. If these variants dif- fer, the different values will be indicated separately. Technical Data 7.1.1 Physical Features All specified data was measured with nominal input voltage, at full load, and an ambient temperature of 25 ℃.
Technical Information Restricted temperature specification applies to occasional data transmission. Functional limitations (in particular for data transmission) may occur with this. 7.1.2 Technological Features Technological Feature Description Ethernet port 10/100 Mbit/s full/half duplex auto sense; automatic detection of "crossover" or "patch" wiring.
Page 22
Technical Information Figure 1: SCR – connections, display and control elements at the top Connector Description V- V+ Power supply Reset Reset key RS232 Serial RS232 interface (D-Sub connector, V.28) SIM card reader (only SCR-L) Cellular antenna (SMA socket, only SCR-L) I/O interface 1 (only SCR-E/L300) Table 3 : SCR –...
Page 23
Technical Information Figure 3: SCR – connections, display and control elements at the front...
Page 24
Technical Information Colour Function blinking 1x during soft reset not availa- Power green Supply 3x during reset to present default settings green WAN chain inactive establishing established Signal no signal logged in (field Signal green (only SCR- or logged strength see Table Link / Activ- not con- green...
Technical Information Power supply The connection to an AC supply network must be made using a suitable power supply unit. Figure 4: SCR – power supply connection Connector Description Power supply, negative terminal Power supply, positive terminal Table 8 : SCR – power supply connections Inputs and Outputs Figure 5: SCR –...
Technical Information RS232 interface Figure 6: SCR – RS232 interface connection Connector Signal Description Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Set Ready Request To Send Clear To Send Ring Indication Table 1 0: SCR – RS232 interface connection ...
Assembly Assembly The SCR can be mounted in two different ways: • Screw mounting using the four mounting lugs • DIN rail mounting using the optional DIN rail adapter This section describes how to mount the SCR, connect the power supply and uninstall it again.
Assembly Screw mounting The four mounting lugs provided at the housing allow mounting on even and stable underground. The mounting material is not included and must be selected accord- ing to the underground. Mounting the device using screws How to mount the router to an even underground: ...
Assembly Screw the router against the underground at all four mounting lugs with a wahser under the screw head. The router is now readily mounted. DIN rail mounting The optional DIN rail adapter (article no. 10020884) is required for DIN rail mount- ing.
Assembly Connecting the power supply Connecting the power supply The device has already been mounted to the DIN rail. The power supply is connected and switched off. Disconnect the push-in terminal connector. Connect the ground lead of the power supply to the terminal "V-" of the terminal connector.
How to connect the SCR to a cellular antenna. The power supply is disabled. You will need a suitable cellular antenna (available from INSYS icom). When selecting and mounting the antenna, make sure to comply with CE conformity.
Page 32
Commissioning Connecting a PC How to connect the SCR to a PC via a network cable. The power supply is disabled. You will need a Cat 5 network patch cable You will need a network card in the PC. Locate the RJ-45 socket of the network card at the PC.
Page 33
Commissioning Enter the user name "insys" and the password "icom". User name and password are set as factory defaults. If the registration at the web interface does not work with the data entered, just reset the device to the factory defaults.
Operating Principle Operating Principle This chapter describes how to operate and configure the router. There are different options for configuration and operation: • Via a web-based interface (web interface). The web interface itself is displayed and operated using a web browser. Operation via web interface and access via HTTPS protocol are described in the following.
Page 35
Enter the user name and the password and click OK. The default settings of the web interface are as follows: the user name is "insys", the password is "icom". The start page of the web interface is displayed.
INSYS MICROELECTRONICS as certification authority. Proceed for this as described in the documentation of your browser. If INSYS MICROELECTRONICS is stored as certification authority in your browser and you access the device again via the HTTPS protocol, the browser indicates again that an invalid security certificate is used.
Operating Principle In order to avoid this browser warning as well, you must enter the Common Name of the router to be accessed into the address bar of your browser. The Common Name must be connected with the IP address of the device that the URL leads to the correct device.
Operating Principle 10.3 Profiles and Profile Handling The configuration of the router is called profile. Several profiles can be stored on one device so that the configuration of a device can be changed quickly. 10.3.1 Term definitions The following terms are to be distinguished: •...
Operating Principle 10.3.3 Using several profiles The versatile possible applications of the router suggest the use of several profiles. The following sections describe the profile handling. 10.3.3.1 Storing a profile Settings made in the opened profile are stored in this profile with a click on the but- ton "OK".
Operating Principle 10.3.3.6 Importing a profile Profiles (in binary format) or ASCII configuration files can be uploaded to the router in the "Administration" menu on the Profiles" page. “ You need to locate the respective file on the computer under "Import profile or ASCII configuration file"...
Repair Send defect devices with detailed failure description to the source of supply of your device. If you have purchased the device directly from INSYS icom, send the device to: INSYS MICROELECTRONICS GmbH, Hermann-Köhl-Str. 22, 93049 Regensburg. Before dispatching the device: •...
Waste Disposal Waste Disposal 12.1 Repurchasing of Legacy Systems According to the new WEEE guidelines, the repurchasing and recycling of legacy systems for our clients is regulated as follows: Please send those legacy systems to the following address, carriage prepaid: Frankenberg-Metalle Gaertnersleite 8 D-96450 Coburg...
Declaration of Conformity 13.1 Devices with radio technology Hereby, INSYS Microelectronics GmbH declares that the device type SCR-L is in compliance with Directives 2014/53/EU and 2011/65/EU. The full text of the EC Declaration of Conformity is available under the following Internet address: www.insys-icom.com/manual...
FCC Statement FCC Statement Note: Certain variants of this device comply with part 15 of the FCC Rules (this is indicated by the FCC symbol on the label). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause unde- sired operation.
Export Restriction Export Restriction The chip sets for analogue modems and cellular radio adapters used by INSYS Mi- croelectronics GmbH are subject to export restrictions as per US ECCN classifica- tion (5A991). Therefore, it is not allowed to export these communication devices into the follow-...
Domain Name System; service used for the translation of domain names into IP addresses. Domain name: The domain is the name of an Internet site (e.g. insys-icom). It consists of the name and an extension (Top Level Domain, e.g. .com), (e.g. insys-icom.com).
Page 47
Glossary GSM: Global System for Mobile communications; cellular network for voice and data transmission. ICMP: Internet Control Message Protocol; protocol that is often used to con- trol a network. The program "ping" uses ICMP for example. Interface: A network device that can transport IP connections. IP address: Internet Protocol address;...
Page 48
Glossary PPP: Point to Point Protocol; a protocol, which connects two machines via a serial line to enable the exchange of TCP/IP packets between those two machines. PPPoE: Point to Point Protocol over Ethernet; a protocol, which connects two devices via an Ethernet line to enable the exchange of TCP/IP packets between those two machines.
Page 49
Glossary VPN: Virtual Private Network; logical connections (so-called tunnels) are es- tablished via existing unsafe connections. The end points of these con- nections (tunnel ends) and the devices behind can be considered as an independent logical network. A very high degree of tap- and tamper- resistance can be achieved with the encryption of the data transmis- sion via the tunnels and the previous two-way authentication of the partcipants at this logical network.
Tables and Diagrams Tables and Diagrams 17.1 List of Tables Table 1: SCR – physical features ................ 20 Table 2: SCR – technological features ..............21 Table 3: SCR – connections, display and control elements at the top ....22 Table 4: SCR –...
Index Index Access Point Name ....... 46 General safety instructions ..... 13 Accessories........19 GPRS ..........46 Additional information ..... 8 Ground.......... 25 Alternative results......8 GSM ..........47 APN..........46 Housing ........14 Assembly ........27 HTTPS........... 36 AT command ........ 46 Humidity ........
Page 52
Index Password .........33, 35 Service Center Number ....48 PC ..........32 Short-cut ......... 14, 41 Permissible limit ......10 Signal LED ........24 Personnel ........10 SIM card ........31 PIN ..........31 SIM card reader ....... 21, 22 Port ..........