• When the unit is not in use, make sure to the spotlight is turned off by rotating the On/Off Power Knob to the furthest position
counterclockwise. Disconnect the 12 volt DC plug end from the accessory outlet of your vehicle or other 12 volt DC power source.
Then unplug the barrel tip of the supplied 12 Volt DC Power Cord from the 12 Volt DC Power Port.
• Replace the end cap on the unit, screwing clockwise until the triangular arrow on the end cap is pointing to the rectangular icon
on the rear of unit. Make sure it fits securely, but do NOT over-tighten.
Note:
When using a vehicle' s 12 volt DC accessory outlet as a charging source, be aware that some vehicles require you to turn on the ignition to power the
accessory outlet.
ImPORTANT NOTES:
• If the 12VDC power cord is plugged during operating by alkaline batteries, the unit will automatically switch to corded use.
• If the 12VDC power cord is unplugged during corded use, the unit will automatically switch to the alkaline batteries mode.
• The unit is NOT waterproof when the waterproof end cap is removed.
WARNING – TO REDUCE THE RISK ELECTRIC SHOCK, INJURY TO PERSONS OR PROPERTY DAmAGE:
This spotlight is NOT waterproof when used with the 12 Volt DC Power Cord. Submerging the spotlight with the 12 Volt DC Power
Cord plugged in to a 12 volt DC power source may result in electric shock and/or permanent damage to the spotlight.
using the carry lanyard (optional accessory)
The carry lanyard may be used to carry the unit or to hang it for storage. Always adjust the slide on the cords to keep the lanyard
secure around any supporting object.
CAUTION: TO REDUCE THE RISK OF PRODUCT DAmAGE:
• When light is hung by the carry lanyard, do not shake the spotlight or object that it is hanging from. Do not hang the spotlight
from any electrical wires or anything that it is not secure.
• Only use the carry lanyard for hanging this spotlight. The carry lanyard is not intended to support additional weight. Do not attach
or hang anything additional to the spotlight or risk of breakage may occur.
Care aND MaiNteNaNCe
If the unit gets dirty, gently clean the outer surfaces of the spotlight unit with a soft cloth moistened with a mild solution of water and
detergent. There are no user-replaceable parts. Periodically inspect the condition of the 12 Volt DC Power Cord, connectors and wires.
Contact manufacturer to replace any components that have become worn or broken.
safe Battery Disposal
Refer to the Safety Warnings in the front of this Instruction Manual when selecting and replacing batteries. Always dispose of used
batteries properly.
WARNING: TO REDUCE THE RISK OF INJURY/EXPLOSION:
• Do not dispose of batteries in fire as this may result in an explosion.
• Do not expose the unit containing batteries to fire or intense heat as it may explode.
Halogen Bulb replacement
• Make sure the spotlight is turned off by rotating the on/off power knob to the furthest position counterclockwise.
• Unscrew the rubber bezel counterclockwise and remove it.
• Carefully remove the light reflector and then the light holder assembly.
grOOVes iN tHe LigHt HOLDer asseMBLy (aLigN
aND Fit iNtO tHe tWO COrresPONDiNg riBs iN tHe
HOusiNg)
HaLOgeN BuLB HOLDer
SPQAK_ManualENSP_092711.indd 6-7
riBs iN tHe HOusiNg (aLigN aND Fit iNtO
tHe tWO COrresPONDiNg grOOVes iN tHe
LigHt HOLDer asseMBLy)
HaLOgeN BuLB asseMBLy
HaLOgeN BuLB
terMiNaL
6
• On the light holder assembly, lift out the halogen bulb from the halogen bulb holder first, then detach the lead wire of halogen
bulb assembly from the halogen bulb terminal.
• Insert the lead wire of replacement bulb assembly into the halogen bulb terminal and place the halogen bulb back into the
halogen bulb holder.
• Put back and align the grooves of the light holder assembly snugly into the ribs of the housing.
• Replace the light reflector.
• Replace the rubber bezel and screw it clockwise. Do not over-tighten.
12 Volt DC Power Cord Fuse replacement
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 5 amp.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Power Cord.

trOuBLesHOOtiNg

Unit will not operate
1. Make sure the On/Off Lock Bar is in the unlocked position.
2. The Rubber Bezel may be loose after the battery or halogen bulb have been replaced. Screw the Rubber Bezel clockwise to
secure. Do not over-tighten. Make sure the internal components are correctly in place following the directions in this manual.
3. The batteries may be completely discharged. Replace the batteries following the directions given in this manual. Make sure
they are correctly installed regarding polarity (+, –) and are properly inserted in the battery compartment as described.
4. The halogen bulb may have blown. Check bulb filament. If the filament is coiled and unbroken, the bulb is not blown.
Otherwise, replace the bulb following the instructions in the manual.
5. If the light does not operate after replacing the batteries, replacing the bulb and/or tightening the rubber bezel, contact the
manufacturer at (877) 571-2391.
Unit will operate in corded mode
1. Check connection to the 12VDC power port.
2. Check connection to the DC power source.
3. Confirm there is a functioning DC current.
4. Check ito see if the fuse if opened (blown).
aCCessOries
Recommended accessories for use with your tool are available from the manufacturer. If you need assistance regarding accessories,
please contact the manufacturer at (877) 571-2391.
WARNING: The use of any accessory not recommended for use with this appliance could be hazardous.
serViCe iNFOrMatiON
Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at (877) 571-2391.
ONe-year LiMiteD WarraNty
The manufacturer warrants this product against defects in materials and workmanship for a period of ONE (1) YEAR from the date
of retail purchase by the original end-user purchaser ("Warranty Period").
If there is a defect and a valid claim is received within the Warranty Period, the defective product can be replaced or repaired in the
following ways: (1) Return the product to the manufacturer for repair or replacement at manufacturer' s option. Proof of purchase
may be required by manufacturer. (2) Return the product to the retailer where product was purchased for an exchange (provided
that the store is a participating retailer). Returns to retailer should be made within the time period of the retailer' s return policy
for exchanges only (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their
specific return policy regarding returns that are beyond the time set for exchanges.
This warranty does not apply to accessories, bulbs, fuses and batteries; defects resulting from normal wear and tear, accidents;
damages sustained during shipping; alterations; unauthorized use or repair; neglect, misuse, abuse; and failure to follow
instructions for care and maintenance for the product.
This warranty gives you, the original retail purchaser, specific legal rights and you may have other rights which vary from state to
state or province to province. This product is not intended for commercial use.
Please complete the Product Registration Card and return within 30 days from purchase of the product to: Baccus Global LLC, 595 S.
Federal Highway, Suite 210, Boca Raton, FL 33432. Baccus Global LLC, toll-free number: (877) 571-2391.
7
9/27/2011 9:10:51 PM

Advertisement

Table of Contents
loading

Table of Contents