Control Panel Assembly - GE JK3800DH1BB Technical Service Manual

Combination wall oven
Hide thumbs Also See for JK3800DH1BB:
Table of Contents

Advertisement

Control Panel Assembly

The control panel assembly consists of an outer
control panel and an inner control panel bracket.
The outer control panel contains the control, display,
selector circuit boards, power and relay circuit
boards. Removing the control panel allows access
to the oven lamp.
The control panel is held in place with nine Phillips
head screws and four tabs. Two of the screws are
recessed from the top of the outer cover. Access
holes are provided. A magnetic screwdriver is
necessary to capture these screws.
To Remove The Control Panel Assembly
1. Remove the two 1/4 in. screws from the
mounting and slide the upper oven out 6 inches.
2. Remove the three Phillips head screws from the
top front of the outer cover.
3. Remove the two recessed Phillips head screws
that attach the control panel assembly to the
top of the frame.
4. Remove the two Phillips head screws that
attach the control panel assembly to the side of
the frame.
5. Remove the two Phillips head screws that
attach the control panel assembly to the front of
the frame.
6. Open the oven door.
7. Grasp the bottom of the control panel assembly
and lift to release the four tabs that hold the
bottom of the control panel assembly to the
oven frame.
8. Disconnect wire harnesses from the power
board.
9. Disconnect wire harnesses from the relay board.