MUX DVBS2 - QAM/COFDM CI Contents Technical specifications ........................References’ description ........................Installation ............................3.1. Wall mount ..........................3.2. 19 inch rack ..........................Elements’ description ........................4.1. Introduction ..........................4.2. Power Supply Unit ........................4.3. Amplifiers ........................... 4.4. Programming Unit ........................Instructions for use ..........................
1. Technical specifications 1.1. MUX DVBS2-QAM CI Ref. 564101, MUX DVBS2-COFDM CI Ref. 564201 Input frequency 950 - 2150 Through losses (typ.) < 1,5 DVB-S2 10 -30 DVB-S2 QPSK, 8PSK Symbol rate Mbaud Modulation DVB-S 2 - 42,5 DVB-S QPSK...
Page 6
MUX DVBS2_QAM/COFDM CI 520 (LNB not powered/ CAM not inserted) 620 (LNB not powered/ CAM inserted) Consumptions @ 24Vdc (with signal) General 870 (one LNB powered/ CAM inserted) 1120 (two LNB powered/ CAM inserted) Protection level * Consumptions are measured with input signal. The consumption indicated for CAM and LNB are highest;...
Page 7
1.3 Power Supply Unit technical specifications Total maximum current Mains voltage/frequency V~ / Hz 196 - 264 / 50-60 5 (24V (OUT1 + OUT2) PSU Ref. 5629 Output voltage Maximum current per output 4 (24V 1.4 Block diagram Ref. 564101 Ref.
3 Installation 3.1 Wall mount SAT IF 564101, 564201 5629 5575 INPUT CLAC! 5071 5239 OUTPUT COFDM (564101) (564201) 4061 7234 NOTE: The use of both PSU power outputs is recommended to balance the consumption. For example, 4+3 or 3+4.
4 Elements’ description 4.1 DVBS2 - QAM CI (564101) / DVBS2 - COFDM CI (564201) CTRL CTRL PRGM PRGM 564101 564201 Insert the smartcard completely into the CAM slot before powering 1. SAT IF input 4. RF output 7. Control BUS connector modules.
MUX DVBS2_QAM/COFDM CI 4.2 Power Supply Unit Connectors to power the modules (1) Masa LED de estado 24V: OK 0V: Overload or short circuit 02340039001 003 Mains input 230V~ REMARKS • The power supply can power up to a maximum of 7 modules with CAM, and being active only 2 LNB feeds of the assembly of seven multiplexer. • When a CAM is inserted, it is assumed that the multiplexer’...
4.3 Amplifiers OPTION “A” - 5575 OPTION “B” - 451202 TEST (-30dB) +10 dB OK - MATV 20 dB 20 dB 10 dB 10 dB 20 dB MATV OK - Return USO EXCLUSIVO EN INTERIOR C. Ret C. Ret FOR INDOOR USE ONLY ¡¡¡ATENCIÓN!!! NO ABRIR.
MUX DVBS2_QAM/COFDM CI 4.4 Programming Unit PCT 5.0 The programming unit features 4 buttons: (short press) - Selection of P C T 4 . 0 parameter (positioning of the U N I V E R S A L cursor). Modification of the parameter chosen by the cursor (flashing).
5 Instructions for use 5.1 Standard menu and DVB-S signals is automatic. Connect the programming unit to the front socket 5.1.a Input menu These parameters will be active when the option of the module (“PRGM”). “Enabled” is selected At first, the controller’s firmware version will The multiplexer consists of 3 demodulator These parameters are only operational when appear:...
Page 16
MUX DVBS2_QAM/COFDM CI 5.1.c Output menu QAM COFDM Mod: 256QAM 8MHz 64QAM Next main menu shows the output frequency/ normal GI:1/8 channel, the output level control and the output Baud:6.900Mb FEC:3/4 mode selection. The available options for this menu as well as their SALIDA SALIDA OUTPUT...
Page 17
5.1.d Identifiers menu Once the search has completed, it is displayed a list in the output (configured as DCY). of services. Each service is part of a list containing Scrambled service in the input, and free all services found in the 3 input channels. The Since the output transport stream is formed service in the output (configured as DCY).
Page 18
MUX DVBS2_QAM/COFDM CI II. Direct access to the services of a particular input 5.1.e.1 PIDs menu become the actual value to take into account, which may vary slightly from the estimate. by selecting the identifier of one of the A/B/C inputs, and again making use of keys and .
Page 19
• » OFF It is not allowed to pass to the output It also shows the peak reached, which Description of the PID function: can be reset by pressing on key. » DCY It passes to the output and requests »...
MUX DVBS2_QAM/COFDM CI 5.2 Extended menu two modes available to program the output unit has been assigned a unique address on the bus, or the units will not communicate. The valid frequency. Choices are: a) By entering the address range goes from 1 to 254 (which is the channel frequency value, and b) by selecting To access this menu make a long press on maximum number of devices controllable from...
Page 21
CONFIG CONFIG CONFIG CONFIG LOOP: ON LOOP: ON LOOP: ON LOOP: ON LNB : 17V ~ LNB : 17V ~ LNB : 17V ~ LNB : 17V ~ 5.2.b Configuration menu 2 be applied either for demodulator A or TEMPERATURA TEMPERATURE demodulators B and C.
Page 22
MUX DVBS2_QAM/COFDM CI » IN A Can be unscrambled services from input sets this number as the maximum of VERSION A, only. PIDs to be sent to the CAM. FW:1.00.4 » IN B Can be unscrambled services from input Thereby, for new services coming into Mod:1.00.9 B, only.
Page 23
check versions or rights of the card. name. service, followed by the service name. Finally, on the last line is displayed the channel And finally, in the bottom line of the screen, is number (LCN) assigned. shown the corresponding number with the original CAM service_id and the service_id value at the output.
The display shows: a. Local control specify the desired name. By default the network is called “TELEVES”. The “Headend Management” software (v2.14.40 It also is possible to manually configure the version Grabando los...
Page 25
LCN TYPE NET NAME CONFIG VERSION CAM CONFIG LCN SID LANGUAGE LOOP: OFF Now: FW:1.00.4 POS:OUT Press A. Direct TELEVES Max: menus Generic NIT version LNB: BC Mod:1.00.9 DCY SEGURO: Fashion TV Start English SAT: B 13V reset N:0003 1003000001!
8. Norms for rack mounting (Max. 49 MUX CI T-0X - 7 subracks with 5 units in height - 8,7”) 8.1. Installation of the rack with These ventilators will be installed on a tray that is fixed inside the cabinet (fig. 1 & 2). This way, the ventilation facilities ventilators will force the fresh air entering from the base of the cabinet, to circulate between the...
Page 28
MUX DVBS2_QAM/COFDM CI 8.2. Installation of the rack without It is very important that this process operates co- rrectly, therefore the following must be observed: ventilation facilities - Do not open the side doors, as this would cause the ventilators to extract the air from the outside To install the units in racks without installation rather than the air inside the rack.
9. Norms for cabinet mounting IMPORTANT EXTRACTOR for forced The scheme of recommended ventilation must be onto ventilation is the one in the figure the highest module. in any case of cabinet placement (horizontal or vertical). Maximum environment temperature: 45ºC. Horizontal The maximum temperature placement...
Page 30
MUX DVBS2_QAM/COFDM CI IMPORTANT Horizontal placement of the cabinets is strongly recommended, hanging them as HORIZONTAL near to the floor as possible. If the horizontal placement is impossible, 0,2 m then vertical placement is allowed. 0,2 m Respect the recommended minimum distances in the attached schemes.
Page 32
MUX DVBS2_QAM/COFDM CI Guarantee Televés S.A. offers a two year guarantee, beginning from the date of purchase for countries in the EU. For countries that are not part of the EU, the legal guarantee that is in force at the time of purchase is applied. Keep the purchase invoice to determine this date. During the guarantee period, Televés S.A.