Installation Of Temperature Controller - Rinnai V53De Installation And Operation Manual

Outdoor tankless water heater
Hide thumbs Also See for V53De:
Table of Contents

Advertisement

Installation of Temperature Controller

WARNING / AVERTISSEMENT
Turn the power off. Do not attempt to connect the
temperature controllers with the power on. Although
the controller is a low voltage device, there is 120 volt
potential next to the temperature controller
connections inside the unit.
Do not connect the temperature controller to the
120VAC terminals provided for the optional solenoid
drain valves.
Controller Location
The controller should be out of reach of small
children.
Avoid locations where the controller may become
hot (near the oven or radiant heater).
Avoid locations in direct sunlight. The digital
display may be difficult to read in direct sunlight.
Avoid locations where the temperature controller
could be splashed with liquids.
Do not install in locations where it can be
adjusted by the public.
Cable Lengths and Sizes
The cable for the temperature controller should be a
non-polarized two-core cable with a minimum gauge
of 22 AWG. The maximum cable length from each
controller to the water heater depends on the total
number of wired controllers connected to the water
heater.
Number of Wired
Maximum Cable Length for each
Controllers
1
2
3 or 4
14
Controller to Water Heater
328 ft (100 m)
164 ft (50 m)
65 ft (20 m)
Configurations
A maximum of 4 temperature controllers can be
installed for a water heater or bank of water heaters.
This includes the controller built into an indoor water
heater. Controllers can only be wired in parallel.
Controllers cannot be wired in series.
If 4 MC-601-US controllers are installed,
simultaneously press the Priority and ON/OFF buttons
on the fourth controller until a beep sounds.
Residential Applications: MC-601-US-BK,
V53De Manual
Wire controllers in parallel
MC-601-US-W